Operation Manual
Table Of Contents
- 软件产品政策
- 免提支架/固定器
- 连接/断开电缆
- 连接主机接口
- 一瞄即扫
- 阅读器的部件
- 条形码编程
- 扫描模式
- 故障排除
- LED 和蜂鸣器指示
- 人体工程学建议
- 管制信息
- 阅读器标签
- Software Product Policy
- Hands Free Stand/Holder
- Connect/Disconnect Cable
- Connect Host Interface
- Aim and Scan
- Parts of the Reader
- Programming Bar Codes
- Scanning Modes
- Troubleshooting
- LED and Beeper Indications
- Ergonomic Recommendations
- Regulatory Information
- Reader Labeling

Scanning Modes
Quick Reference Guide 31
Scanning Modes
The reader can operate in one of several scanning modes:
Trigger Single —
When the trigger is pulled, scanning is activated
until one of the following occurs:
- a programmable duration
1
has elapsed
- a label has been read
- the trigger is released
This mode is associated with typical handheld reader operation:
when the trigger is pulled, scanning starts and the product scans
until the trigger is released, or a label is read, or the maximum
programmable duration
1
has elapsed.
Trigger Hold Multiple —
When the trigger is pulled, scanning starts
and the product scans until the trigger is released or a program-
mable duration
1
has elapsed. Reading a label does not disable
scanning. Double Read Timeout
2
prevents undesired multiple
reads while in this mode.
Trigger Pulse Multiple —
When the trigger is pulled and released,
scanning is activated until programmable duration
1
has elapsed
or the trigger has been pulled again to transition to another
state. Double Read Timeout
2
prevents undesired multiple reads
while in this mode.
Flashing —
The reader flashes
3
on and off regardless of the trigger
status.
Always On —
No trigger pull is required to read a bar code. Scan-
ning is continually on. Double Read Timeout
4
prevents unde-
sired multiple reads while in this mode.
Autosense® Stand Mode —
No trigger pull is required to read a bar
code. Scanning is turned on automatically when an item is
placed in reader’s field of view. If the trigger is pulled, the reader
acts as if it in Trigger Single mode. Double Read Timeout
5
prevents undesired multiple reads while in this mode.
NOTE
If the interface type is changed, scanner configu-
ration may be automatically reset to a different
Scanning Mode.
1. See the Product Reference Guide (PRG) for additional programmable
features, in this case: Scanning Active Time.
2. Double Read Timeout is also programmed using the PRG.
3. Controlled by Flash On Time and Flash Off Time. Use the PRG to pro-
gram these options.
4. Double Read Timeout is programmed using the PRG.
5. Double Read Timeout is programmed using the PRG.