QuickScanTM L QD 2300 Barcode Scanner Quick Reference Guide
Datalogic ADC, Inc. 959 Terry Street Eugene, OR 97402 USA Telephone: (541) 683-5700 Fax: (541) 345-7140 © 2007-2013 Datalogic, Inc. An Unpublished Work - All rights reserved. No part of the contents of this documentation or the procedures described therein may be reproduced or transmitted in any form or by any means without prior written permission of Datalogic ADC, Inc. or its subsidiaries or affiliates ("Datalogic" or “Datalogic ADC”).
Connect/Disconnect Cable 1 Connect/Disconnect Cable Connect Host Interface 2 Keyboard Wedge Interface RS-232 Interface USB Interface Quick Reference Guide 1
Aim and Scan 3 012345 012345 65° 65° 2 QuickScanTM L
Parts of the Scanner Parts of the Scanner LED Scan Window Trigger Nose Boot Scanning Modes The scanner can operate in two modes: • Trigger Single Mode - trigger button must be pressed to emit the laser in order to a scan barcode. or • Stand Mode - scanner laser is in constant on state and no trigger button press is required to scan a barcode. To toggle between modes, scan the “Toggle Scan Mode” barcode below.
Stand Mode Timeout Period The Timeout Period for the transition from low power to sleep mode can be set to one of the following durations: • 1 Hour • 5 Hours (default) • Infinite Timeout — With this setting, there is no timeout, thus the scanner will never go into sleep mode or beam shut-off but will remain in low power mode until a label is read.
Troubleshooting Troubleshooting Problem Possible Cause Nothing happens when the scan button is pulled. Possible Solutions Check system power. No power to the scanEnsure power supply is ner. connected. Interface or power cables are loose. Ensure all cable connections are secure. Scanner not programmed for correct barcode type. Ensure scanner is programmed to read the type of barcode scanned. Refer to the Product Reference Guide (PRG) for more information. Barcode label is unreadable.
Beeper Definitions The scanner issues different beep sequences and patterns to indicate status. The table below defines beep sequences that occur during both normal scanning and while programming the scanner. Beeper Sequence Indication Standard Use Low/medium/high beep Power up. Short high beep A barcode label was decoded (if decode beeper is enabled). 4 long low beeps A transmission error was detected in a scanned barcode. The data is ignored. This occurs if a unit is not properly configured.
LED Definitions Beeper Sequence Indication A successful transmission of buffered data. Low/high beep Host Specific USB only 4 short high beeps Scanner has not completed initialization. Wait several seconds and scan again. Scanner gives a power-up beep after scanning a USB Device Type. Communication with the bus must be established before the scanner can operate at the highest power level. The power-up beep occurs more than once.
Programming Barcodes Descriptions This guide includes the programming barcodes required to set up the scanner to work with various host interfaces. Some frequently used programming barcodes are also included. For all programming barcodes, plus detailed information about the scanner, download the latest version of the Product Reference Guide (PRG), Advanced Data Formatting (ADF) Guide and all documentation pertaining to the scanner from the website listed on the back cover of this manual.
Carriage Return / Line Feed Carriage Return / Line Feed If a carriage return/enter is required after each scanned bar code, scan the following bar codes in order: 1. SCAN OPTIONS 2.
Programming Barcodes SET DEFAULTS Keyboard Wedge Interface IBM PC/AT and IBM PC COMPATIBLES IBM PS/2 (MODEL 30) 2 Country Keyboard Types (Country Codes) 5001 5002 5003 5004 5005 5006 5007 5008 5009 5010 7008 7009 7014 7012 7003 7013 7004 7011 7002 NORTH AMERICAN (Default) FRANÇAIS/FRENCH Windows FRANÇAIS CANADIAN/ FRENCH CANADIAN Windows 95/98 10 QuickScanTM L
Programming Barcodes Country Keyboard Types (Country Codes) — cont.
RS-232 Interface STANDARD RS-232 ICL RS-232 RS-232 WINCOR-NIXDORF MODE A RS-232 WINCOR-NIXDORF MODE B RS-232 FUJITSU RS-232 OPOS For USB OPOS operation, use host type USB OEM HANDHELD and an appropriate driver supplied by Datalogic. NOTE There are many more country settings for the USB Keyboard. Please refer to the PRG, downloadable from the website located on the back cover of this manual.
Ergonomic Recommendations Ergonomic Recommendations In order to avoid or minimize the potential risk of ergonomic injury follow the recommendations below. Consult with your local CAUTION Health & Safety Manager to ensure that you are adhering to your company’s safety programs to prevent employee injury.
Hinweis Benutzen Sie nur eine von Datalogic genehmigte Stromversorgung. Die Modelle erfordern eine Stromquelle der Klasse II oder III mit einer Leistungsbegrenzung (LPS). Für eine gültige Sicherheitszertifizierung müssen Klasse III Stromquellen am Eingang nach den Bestimmungen IEC/EN60950-1 (EN 60335-Serien, EN 60065 oder entsprechenden) zugelassen sein. Eingang: 100 - 240 VAC Ausgang: 5.0 VDC Max. Strom: 0.4 Amps Max.
Replacing the Scan Window Marking and European Economic Area (EEA) Laser Devices This device uses lasers complying with 21CFR1040.10 and 1040.11 except for deviations pursuant to Laser Notice No. 50, dated June 24, 2007. IEC/EN60825-1:2007. The laser classification is marked on one of the labels on the device.
ner then hold the scanner with the Scan Window facing up. Gently pull off the Nose Boot and tilt the scanner to one side to remove the window. Proceed to the next step immediately. DO NOT leave the interior of the scanner exposed. CAUTION Holding it by its edges, carefully place the clean replacement Scan Window in position and secure it in place by reinstalling the Nose Boot. Scanner Labeling Labels are shown here to illustrate their location only.
Scanner Labeling International Caution Statements Class 1 and 2 English This scanner is certified in the U.S. to conform to the requirements of DHHS/CDRH 21CFR Subchapter J and to the requirements of IEC 60825-1. Class 1 or Class 2 products are not considered to be hazardous. The scanner contains internally a Visible Laser Diode (VLD) whose emissions do not exceed the maximum limits as set forth in the above regulations.
Anvendelse af optiske systemer med scanneren øger risikoen for øjenskader. Optiske systemer omfatter kikkerter, mikroskoper og lupper. Det omfatter ikke anvendelse af almindelige briller. Dutch Deze scanner is in de V.S. goedgekeurd en voldoet aan de vereisten van DHHS/CDRH 21CFR Subchapter J een aan de vereisten van IEC 60825-1. Producten van klasse 1 (Class 1) en klasse 2 (Class 2) worden niet geacht gevaarlijk te zijn.
Scanner Labeling Los productos de Clase 1 o Clase 2 no se consideran como peligrosos. El escáner tiene en su interior un Diodo Láser Visible (VLD) cuyas emisiones no exceden los límites máximos fijados en los reglamentos mencionados anteriormente. El escáner está diseñado de modo que las personas no tengan acceso a la luz láser peligrosa durante la operación normal, el mantenimiento por parte del usuario o durante las operaciones de servicio prescritas.
Hebrew Datalogic ADC Limited Factory Warranty Warranty Coverage Datalogic ADC (“Datalogic”) hardware products are warranted against defects in material and workmanship under normal and proper use. The liability of Datalogic under this warranty is limited to furnishing the labor and parts necessary to remedy any defect covered by this warranty and restore the product to its normal operating condition. Repair or replacement of product during the warranty does not extend the original warranty term.
Scanner Labeling uct from Datalogic or until the expiration of the original warranty period, whichever is longer.
(iii) any claimed defect or damage caused by the use of product with any other instrument, equipment or apparatus; (iv) any claimed defect or damage caused by the failure to provide proper maintenance, including but not limited to cleaning the upper window in accordance with product manual; (v) any defect or damage caused by natural or man-made disaster such as but not limited to fire, water damage, floods, other natural disasters, vandalism or abusive events that would cause internal and external componen
Scanner Labeling CIRCUMSTANCES WILL DATALOGIC BE LIABLE TO CUSTOMER OR ANY THIRD PARTY FOR ANY LOST PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL IN-DIRECT, SPECIAL OR CONTINGENT DAMAGES REGARDLESS OF WHETHER DATALOGIC HAD ADVANCE NOTICE OF THE POSSIBILITY OF SUCH DAMAGES. Risk of Loss Customer shall bear risk of loss or damage for product in transit to Datalogic. Datalogic shall assume risk of loss or damage for product in Datalogic’s possession.
24 汞 o 铅 x o 镉 Hexavalent Chromium (Cr(VI)) Polybrominated biphenyls (PBB) o 六价铬 o 多溴联苯 有毒有害物质或元素 Cadmium (Cd) o 多溴二苯醚 Polybrominated diphenyl ethers (PBDE) RoHS TABLE,CHINA,QUICKSCAN L EFUP determined by “Look-up Method” (scanner).
DECLARATION OF CONFORMITY 13 EC-69 Rev.:1 Pag.: 1 di 1 Datalogic ADC, Inc. 959 Terry Street Eugene, Oregon 97402 USA La presente dichiarazione di conformità è rilasciata sotto la responsabilità esclusiva di Datalogic ADC, Inc. per: This Declaration of Conformity is issued under the sole responsibility of Datalogic ADC, Inc.
www.datalogic.com © 2007 - 2013 Datalogic, Inc. • All rights reserved. Datalogic and the Datalogic logo are registered trademarks of Datalogic S.p.A. in many countries, including the U.S.A. and the E.U. Datalogic ADC, Inc. 959 Terry Street | Eugene |OR 97402 | USA Telephone: (1) 541-683-5700 | Fax: (1) 541-345-7140 820024114 (Rev.