Instruction manual

MATRIX 300™ REFERENCE MANUAL
36
2
Learn (Function 4)
Once entered, the imager starts a procedure to automatically detect and recognize codes
which are presented to it.
The Learn LED will blink until the procedure is completed.
The Learn procedure ends when the Image Processing and Decoding parameters are
successfully saved in the reader memory, the Green Spot is activated, the Learn LED will stop
blinking and Matrix 300™ emits 3 high pitched beeps.
If the autolearning cannot be reached after a timeout of about 3 (three) minutes, Matrix 300
will exit without saving the parameters to memory, the Learn LED will stop blinking and in this
case Matrix 300™ emits a long low pitched beep.
You can exit the Learn function at any time by pressing the X-PRESS™ push button once.
After a short delay the Learn procedure is cancelled.
2.5.2 Diagnostic Indication
The “STATUS” and “READY” LEDs blink simultaneously while the "GOOD" LED is on to
signal the presence of an error. Diagnostic message transmission on interfaces can be
enabled to provide details about specific error conditions. See the Diagnostic Error
Conditions chart in the Help On Line.
LED
STATUS
READY
BLINK
GOOD
ON to indicate an error
TRIGGER
COM
STATUS
BLINK
2.6 MODEL DESCRIPTION
Matrix 300™ readers are described by their model number which indicates the
characteristics listed in the diagram below. Not all combinations are available. For a
complete list of combinations see the Models tab on the Product page of the website.
MATRIX 300 4XX-0XX
Internal Illuminator
1 = Wide Angle Red
5 = Wide Angle White
7 = Light DPM
8 = Multi-Light DPM
Input Power
1 = Standard 10 - 30 Vdc
4 = PoE 48 Vdc
Options
0 = Standard
1 = ESD Safe
2 = ESD Safe + YAG Cut Filter
Lens Type
1 = 6 mm (fixed lens manual focus)
2 = 9 mm (liquid lens auto focus)