QLM700 INSTALLATION MANUAL
5
MECHANICAL INSTALLATION
QLM700 can be mounted to various surfaces using the two M5x20 screw and washers
included in the package:
The M5x20 screws can be used to mount the QLM700 to metallic/plastic surfaces already
prepared with M5 threaded holes.
QLM700 can also be mounted to a Bosch Frame using the two M5x20 screws included in
the package, plus two specific commercial T-nuts (for example the Bosch Rexroth T-nut 10
M5, cod. 3 842 530 283).
Mounting to other surfaces, such as concrete walls or metallic panels, requires
appropriate user-supplied parts (screws, screw anchors, nuts, etc).
The diagram below gives the overall dimensions of the QLM700 and shows the mounting
through-holes.
39
[1.55]
9.5
[0.37]
5.5
[0.22]
n° 2
5.5
[0.22]
n° 4
188
[7.40]
200
[7.88]
53.5
[2.11]
81
[3.18]
= =
= =
Figure 2 - Overall Dimensions
Mounting
Slots (6)
mm