Installation manual

QLM700 INSTALLATION MANUAL
14
TECHNICAL FEATURES
ELECTRICAL FEATURES
Supply Voltage 10 to 30 Vdc
Consumption 0.3 - 0.2 A
Maximum Distributed Current Allowed
ID-NET™
4.0 A max
Limited Current Consumption
QLM700 + reading device
Trigger + I/O device
(see related device manuals)
1.85 A max
0.75 A max
Inputs: Input1 (TRG), Input 2
Voltage
Current Consumption
Optocoupled
30 Vdc max.
12 mA max.
Outputs: Output 1, Output 2
V
CE
Collector Current
V
CE
Saturation
Power Dissipation
Optocoupled
30 Vdc max.
40 mA continuous max.; 130 mA pulsed max.
1V max. @ 10 mA
80 mW max. @ 45 °C (ambient temperature)
COMMUNICATION INTERFACES
Host Interface Profinet IO 10/100 Mbit/s
Auxiliary RS232 up to 115.2 kbit/s
ID-NET™ RS485 Half Duplex up to 1 Mbit/s
Communication Protocols Datalogic Application Driver (DAD Driver)
USER INTERFACE
LED Indicators:
Power/ID-NET
Trig
I/O
ETH1
ETH2
Power On/Polarity Error (blue/red)
Trigger Activity (yellow)
IN2 (yellow), OUT1 (red), OUT2 (green),
Network Status (green/red), Link Activity (green/yellow),
Module Status (green/red), Link Activity (green/yellow)
PHYSICAL FEATURES
Mechanical Dimensions
200 x 81 x 40 mm
(7.9 x 3.2 x 1.6 in.)
Weight 500 g. (17.64 oz.)
ENVIRONMENTAL FEATURES
Operating Temperature
0° to 50 C (+32° to 122 °F)
Storage Temperature
-20° to 70 C (-4° to 158 °F)
Humidity max. 90% non condensing
Vibration Resistance 14 mm @ 2 to 10 Hz; 1.5 mm @ 13 to 55 Hz;
EN 60068-2-6 2 g @ 70 to 200 Hz; 2 hours on each axis
Bump Resistance 30 g; 6 ms;
EN 60068-2-29 5000 shocks on each axis
Protection Class EN 60529 IP65 *
The features given are typical at a 25 C ambient temperature (if not otherwise indicated).
* when all the M12 connectors and reading device are correctly connected (or closed with a proper
protection cap).