Installation manual

25-PIN CABLE ELECTRICAL CONNECTIONS
65
5
5.3.3 ID-NET™ Network Termination
The network must be properly terminated by a 120 Ohm resistor at the first and last scanner
of the network.
5.4 AUXILIARY RS232 INTERFACE
The auxiliary serial interface is used exclusively for RS232 point-to-point connections.
The parameters relative to the aux interface (baud rate, data bits, etc.) as well as particular
communication modes such as LOCAL ECHO can be defined using the Genius utility
program or Genius™ based Host Mode Programming installed from the CD-ROM.
The following pins of the 25-pin connector are used to connect the RS232 auxiliary interface:
Pin
Name
Function
20
RX
Receive Data
21
TX
Transmit Data
7
GND
Ground
7
GND
GND
TXD
RX
20
RXD
TX
21
USER INTERFACE
DS2100N
1
Chassis
Figure 73 - RS232 Auxiliary Interface Connections