1D Symbologies Enter/Exit Programming Mode
Product Reference Guide  
 151
Codabar Set Length 2
This feature specifies one of the bar code lengths for Codabar Length Control on page 149Cod-
abar Length Control on page 149. Length 2 is the maximum label length if in Variable Length 
on page 251 Mode, or the second fixed length if in Fixed Length on page 251 Mode. The length 
includes the bar code’s start, stop, c
heck and data characters. The length must include at least 
one data character.
The length can be set from 3 to 50 characters. A setting of 0 specifies to ignore this length 
(o
nly one fixed length).
Table 14 provides examples for setting Length 2. See page 251 for detailed instructions on set-
ting this feature.
Table 14. Codabar Length 2 Setting Examples
STEP ACTION EXAMPLES
1
Desired Setting (and pad 
with leading ze
roes)
00 Ignore This 
Length
07 Characters 15 Characters 50 Characters
2 Scan ENTER/EXIT PROGRAMMING MODE
3 Scan SELECT CODABAR LENGTH 2 SETTING
4
Scan Two Characters From 
Appendix D, Keypad
 ‘0’ and ‘0’ ‘0’ and ‘7’  ‘1’ and ‘5’  ‘5’ AND ‘0’
5 Scan ENTER/EXIT PROGRAMMING MODE
$CCBL2
Select Codabar Length 2 Setting
Make a mistake? Scan the CANCEL bar code to abort and 
not save the entry string. You can then start again at the 
beginning.
~
CANCEL
DEFAULT
50 = Length 2 is 50 Characters