User Manual

1D Symbologies Enter/Exit Programming Mode
Product Reference Guide
151
Codabar Set Length 2
This feature specifies one of the bar code lengths for Codabar Length Control on page 149Cod-
abar Length Control on page 149. Length 2 is the maximum label length if in Variable Length
on page 251 Mode, or the second fixed length if in Fixed Length on page 251 Mode. The length
includes the bar code’s start, stop, c
heck and data characters. The length must include at least
one data character.
The length can be set from 3 to 50 characters. A setting of 0 specifies to ignore this length
(o
nly one fixed length).
Table 14 provides examples for setting Length 2. See page 251 for detailed instructions on set-
ting this feature.
Table 14. Codabar Length 2 Setting Examples
STEP ACTION EXAMPLES
1
Desired Setting (and pad
with leading ze
roes)
00 Ignore This
Length
07 Characters 15 Characters 50 Characters
2 Scan ENTER/EXIT PROGRAMMING MODE
3 Scan SELECT CODABAR LENGTH 2 SETTING
4
Scan Two Characters From
Appendix D, Keypad
‘0’ and ‘0’ ‘0’ and ‘7’ ‘1’ and ‘5’ ‘5’ AND ‘0’
5 Scan ENTER/EXIT PROGRAMMING MODE
$CCBL2
Select Codabar Length 2 Setting
Make a mistake? Scan the CANCEL bar code to abort and
not save the entry string. You can then start again at the
beginning.
~
CANCEL
DEFAULT
50 = Length 2 is 50 Characters