Operation Manual
Product Reference Guide 89
\
Enter Reader Configuration
DATA FORMAT
Exit and Save Reader Configuration
Symbology Specific Format
1. Select a Datalogic Standard Code Identifier from the Code Identifier Table in
Appendix D.
2. Formatting:
0 = select all - Stop
1 = select right - followed by Step 3
2 = select left - followed by Step 3
3 = select middle - followed by a number in the range 000-999 for the starting charac-
ter and then, by Step 3
4 = discard right - followed by Step 3
5 = discard left - followed by Step 3
6 = discard middle - followed by a number in the range 000-999 for the starting char-
acter and then, by Step 3
3. Set the number of characters to select/discard in the range 000-999.
Symbology Headers
1. Select a Datalogic Standard Code Identifier from the Code Identifier Table in
Appendix D.
2. Set the number of characters in the range 0-5.
3. Read the corresponding characters as Hex values from the Hex/Numeric table. Valid
v
alues are in the range:
• 00-7F for RS-232, USB BULK, USB COM, USB Generic HID
• 00-9B for Wedge and USB Keyboard
4. Read the following code to enable
the configuration you have set.
Symbology Specific Format