Operation Manual

Setup Procedures
Product Reference Guide 35
Go to
"Interface Selection"
on page 41.
5.
Set Radio Address
+
four digits for the PowerScan™ M8500 Address (from
0000
to
1999
).
All readers used in the same area must have different addresses.
6.
Exit and Save Configuration
7.
Read the
Bind
code to pair the PowerScan™ M8500 to the BC-80X0 cradle. The reader is dedi-
cated to the cradle. Any previously
bound
reader will be excluded.
To connect several readers to the same cradle see
"Using Multiple M-Series Readers with Same Cradle"
on page 36
Bind
The green LED on the PowerScan™ M8500 will blink; the reader is ready to be inserted into the
cradle.
8.
Firmly insert the reader into the BC-80X0 cradle within 10 seconds, a beep will be emitted, sig-
naling that the BC-80X0 cradle has been paired to
the PowerScan™ M8500, and the green LED
on the reader will go off.
Read the BC-80X0 restore default code:
9.
Restore BC-80X0 Default