Operation Manual
PowerScan M8500 Setup
20 PowerScan™ M8500
Network Connections
BC-8060 Network Connectors
The multidrop network is a bus system which is propagated from one BC-8060 cradle to
another using individual cables. This is possible thanks to the RS-485 connector on the
front panel of the cradle.
Figure 10. Network Connectors
All cradles are connected together within the bus system through the Datalogic RS-485
splitter cable (CAB-428, part number 90A051950), which must be inserted in the RS-485
cradle connector.
Cable length should be kept to a minimum,
as with all bus systems.
Network Cabling
The Multidrop line is made using RJ45 connectors and a cable having the following
specifications:
• twisted pair AWG 24 wires
• 120 im
pedance
•
maximum network cable length 1200 meters
Pin Function
1 RS-485 +
2 RS-485 -
3 N.C.
4 VDC –
5 VDC –
6 N.C.
7 VDC +
8 VDC +
5
2
RJ45
5
2
RJ45
1 1
VDC-
RS-485-
RS-485+
Twisted Pair
–
RS-485 bus
8
5
2
RJ45
8
5
2
RJ45
1 1
Twisted Pair – RS-485 bus
Twisted Pair - Power suppl
y
VDC+
VDC-
RS-485-
RS-485+