Operation Manual
Product Reference Guide 187
Appendix B
Host Configuration Strings
In this section we provide a description of how to modify the device configuration using
serial strings sent from the Host.
The device configuration can be changed by receiving commands from the Host through
the serial inte
rface. When this method is used, the programming sequence format is the
following:
Example:
Each configuration parameter setting removes the condition previously active for that
parameter.
This method requires the RS-232 or USB-Com interface.
The device buffer can contain about 400 characters. If your program-
ming string
goes over this value, you must split it into separate groups
and send each group after a delay of at least 3 seconds to give the reader
time to empty the buffer and interpret the commands.
Command
Character sequence in following tables
CR$-$+
Carriage return character (0D Hex.)
Enter configuration environment
Exit and Save configuration
Beeper tone 1
Beeper low intensity
BG1
$-
CR
Carriage return character (0D Hex.)
Exit and save new configuration
AC410132BH0
Matrix 2/5 3 bars: no check digit,
variable length code from 1 to 32 characters
$+
Enter configuration environment
Multiple command programming sequence: