Operation Manual
References
160 PowerScan™ M8500
EXAMPLES
- Defining Special Key Sequences -
1. The following example allows defining Special Key 1 as SHIFT + F5:
2. The following example allows defining Special Key 2 as CTRL + S (upper case):
3. The following example allows defining Special Key 3 as Alt + F6:
4. The following example allows defining Special Key 4 as Alt + Shift + F1:
enter
configuration define Special Key 1 SHIFT
Read + + +
codes from Appendix F
corresponding to the
character value for F5
exit & save
configuration
+
003
+
enter
configuration define Special Key 2 CTRL + SHIFT
Read + + +
codes from Appendix F
corresponding to the
character value for s (lower
case)
exit & save
configuration
+
01B
+
enter
configuration define Special Key 3 ALT
Read + + +
codes from Appendix F
corresponding to the
character value for F6
exit & save
configuration
+
00B
+
enter
configuration define Special Key 4 ALT + SHIFT
Read + + +
codes from Appendix F
corresponding to the
character value for F1
exit & save
configuration
+
005
+