Operation Manual
Enter/Exit Programming Mode
34
PowerScan™ PD9530/PBT9500/PM9500
ACK NAK Timeout Value
This option specifies the amount of time the reader waits for an ACK charac-
ter from the host following label transmissi
on. The selectable timeout range
is 200 milliseconds to 15,000ms (15 seconds) in 200ms increments. A
selection of 0 disables the timeout.
See page 260 for more information on setting this feature.
$CR2AT
Select ACK NAK Timeout Value Setting
To configure this feature, scan the ENTER/EXIT
PROGRAMMING MODE bar code above, then the bar
code at left followed by the digits from the Alphanu-
meric characters in
Appendix D, Keypad
repre-
senting your desired character(s). End by scanning
the ENTER/EXIT bar
code again.
Make a mistake? Scan the CANCEL bar code to abort
an
d
not save the entry string. You can then start
again at the beginning.
~
CANCEL
DEFAULT
01 ACK NAK Timeout value is 200ms
ACK NAK Retry Count
This feature specifies the number of times the reader retries a label trans-
mission due to a retry condition. The selectable
range is from 1 to 254
retries. A selection of 0 disables the count, and a selection of 255 specifies
unlimited retries. See page 261 for more information.
$CR2AR
Select ACK NAK Retry Count Setting
To configure this feature, scan the ENTER/EXIT
PROGRAMMING MODE bar code above, then the bar
code at left followed by the digits from the Alphanu-
meric characters in
Appendix D, Keypad
repre-
senting your desired character(s). End by scanning
the ENTER/EXIT bar
code again.
Make a mistake? Scan the CANCEL bar code to abort
an
d
not save the entry string. You can then start
again at the beginning.
~
CANCEL
DEFAULT
003 = 3 Retries