Operation Manual
Step 5 — Select Protocol
Select the communications protocol you are using and click Next.
USB
1. Print USB Connect Mode symbol (also shown in Install
Datalogic ESP step) and decode it with the imager to
ensure that you are in the correct communications mode.
Keep printed symbol in a convenient place for future use.
2. Click
Next
when you are finished, and then click
Connect
when
you see the “Reader ID” number in the
Select Device
field.
RS-232
Select
RS-232
and click the
Show Connect Symbol
button.
Print the RS-232 Connect Mode symbol and decode it to
ensure that you are in the correct communications mode.
Keep the printed symbol in a convenient place for future
use. Click Next to return to the RS-232 dialog. Configure
RS-232 settings and COM port and click Connect.
From the default
USB settings, click
the Switch Mode
button to connect to
the reader in USB
HID Mode.
Click the Show
Connect Symbol
button for RS-232
Connect Mode
symbol.
Step 7 — Configure the Imager
Datalogic ESP’s EZ Mode is the first view that appears once
you are connected. This view features simple instructions and
tools for decoding symbol data and capturing images.
From here, you can click on App Mode to access tree controls
and graphic user interfaces with more comprehensive configuration
options.
Step 6 —
Connect to ESP
USB
Once you have clicked Connect in the USB imager ID dialog
(Step 5), the CONNECTED message will appear in a green box
in the status bar at the bottom right of the screen.
You are now ready to configure the USB POWERSCAN D8590
using Datalogic ESP.
RS-232
Once you have selected RS-232 settings and COM port and
clicked Connect, the CONNECTED message will appear in a
green box in the status bar at the bottom right of the screen.
You are now ready to configure the RS-232 POWERSCAN D8590
using Datalogic
ESP
.
Illumination Quick Setup
The following programming symbols allow you to set up and
control Dot Peen Enhanced illumination settings.
Illumination Default
Mode
Dot Peen Enhanced
Illumination Mode -
Large Mark
Dot Peen Enhanced
Illumination Mode -
Medium Mark
Dot Peen Enhanced
Illumination Mode -
Small Mark
Save
Settings
Frequently-Used Settings
The following programming symbols allow you to control
USB Keyboard
Mode, Targeting settings, and Beep and Vibration settings.
USB Keyboard
Mode
Targeting
LED On
(Default)
Targeting
LED Off
Vibrate On /
Beep On
(Default)
Vibrate On /
Beep Off
Vibrate Off /
Beep On
Save
Settings
Step 8 — Practice Decoding
The POWERSCAN D8590 features simple blue targeting LEDs to
indicate optimal read range.
1. Hold the imager about 6”
from the mark and align
the blue targeting pattern
as shown here.
2. Move the front of the imager
steadily downward toward
the mark and parallel to the
mark surface.
3. The imager will decode the
mark at the optimal read
distance – typically from the
point of contact to .50”
(contact – 12.70 mm).
Test