Specifications
DATA FORMAT
70
CODE IDENTIFIER TABLE
CODE
AIM
STAN
DARD
DATALOGIC
STANDARD
Custom
2/5 interleaved
] I y
N
2/5 industrial
] X y
P
2/5 normal 5 bars
] S y
O
2/5 matrix 3 bars
] X y
Q
EAN 8
] E 4
A
EAN 13
] E 0
B
UPC A ] X y C
UPC E ] X y D
EAN 8 with 2 ADD ON ] E 5 J
EAN 8 with 5 ADD ON ] E 6 K
EAN 13 with 2 ADD ON
] E 1
L
EAN 13 with 5 ADD ON
] E 2
M
UPC A with 2 ADD ON
] X y
F
UPC A with 5 ADD ON
] X y
G
UPC E with 2 ADD ON
] X y
H
UPC E with 5 ADD ON
] X y
I
Code 39
] A y
V
Code 39 Full ASCII
] A y
W
CODABAR
] F y
R
ABC CODABAR
] X y
S
Code 128
] C y
T
EAN 128
] C y
k
ISBT 128
] C4
f
Code 93
] G y
U
CIP/39
] X y
Y
CIP/HR
] X y
e
Code 32
] X y
X
MSI
] M y
Z
Code 11
] H y
b
Code 16K
] K 0
p
Code 49 ] T y q
GS1 DataBar™ Expanded Linear and Stacked ] e 0 t
GS1 DataBar Limited ] e 0 v
GS1 DataBar 14 Linear and Stacked
] e 0
u
• AIM standard identifiers are not defined for all codes: the X identifier is assigned to the
code for which the standard is not defined. The y value depends on the selected options
(check digit tested or not, check digit tx or not, etc.).
• When customizing the Datalogic Standard code identifiers, 1 or 2 identifier characters can
be defined for each code type. If only 1 identifier character is required, the second character
must be selected as FF (disabled).
• The code identifier can be singly disabled for any code by simply selecting FF as the first
identifier character.
• Write in the Custom character identifiers in the table above for your records.