Specifications
POWERSCAN
™
D8330/M8300/M8300-DK
218
DATA FORMAT
NOT FOR PEN EMULATION INTERFACES
DESCRIPTION
STRING
Code Identifier disable
EB0
Datalogic standard
EB1
AIM standard
EB2
custom
EB3
Custom Code Identifier
EHabc
Headers
no header
EA00
one character
EA01x
two characters
EA02xx
three characters
EA03xxx
four characters
EA04xxxx
five characters
EA05xxxxx
six characters
EA06xxxxxx
seven characters
EA07xxxxxxx
eight characters
EA08xxxxxxxx
Terminators
no terminator
EA10
one character
EA11x
two characters
EA12xx
three characters
EA13xxx
four characters
EA14xxxx
five characters
EA15xxxxx
six characters
EA16xxxxxx
seven characters
EA17xxxxxxx
eight characters
EA18xxxxxxxx
a = ASCII character.
b, c, x = HEX values representing an ASCII character.
a = AS
CII character of the DATALOGIC STANDARD Code Identifier from the table on page 70.
b = Hex value of the first Custom Code Identifier character from 00 to FD;
FF = disable Code Identifier
c = Hex value of the second Custom Code Identifier character from 00 to FD;
FF = disable second character of Custom Code Identifier
x = Hex
value from 00 to FE