Instructions
Enter/Exit Programming Mode
260
PowerScan™ PD9530/PBT9500/PM9500
ADDITIONAL FEATURES FOR 16-KEY MODELS
See also "Function Keys Configuration (16-key models only)" on page 255. 
Last Code Shown Timeout
After the CODE transmission, the last code read will be shown on the display 
for a configurable timeout (LAST CODE SHOWN TOUT). 
The standard DISPLAY OFF TIMEOUT (see 
page 248
) has a higher pri-
ority than the LAST CODE SHOWN TOUT, so the 
two parameters should 
be combined to get the desired result.
.
$CDIST
Last Code Shown Timeout
To configure this feature, scan the ENTER/EXIT PRO-
GRAMMING MODE bar code above, then the bar code at 
lef
t followed by 2 digits (00-63 by 01) from the Alphanu-
meric characters in 
Appendix D, Keypad.
End by scanning the ENTER/EXIT bar code again.
Make a mistake? Scan the CANCEL bar code to abort and 
not save the ent
ry string. You can then start again at the 
beginning.
~
CANCEL
Display Time Stamping Mode
Time Stamping Mode can be applied when entering data from either a bar-
code, from the keyboard, or both.
$CDITS00\r
Applied to both
DEFAULT
$CDITS01\r
Applied only to barcode data
$CDITS02\r
Applied only to keyboard data