Instruction manual
MATRIX 400™ QUICK GUIDE
4
STEP 2 – CONNECT THE SYSTEM
To connect the system in a Stand Alone configuration, you need the hardware indicated in Figure 2. In this layout
the data is transmitted to the Host on the main serial interface. Data can also be transmitted on the RS232
auxiliary interface independently from the main interface selection. When One Shot or Phase Mode Operating
mode is used, the reader is activated by an External Trigger (photoelectric sensor) when the object enters its
reading zone.
Figure 2 – Matrix 400™ in Stand Alone Layout
CBX100/CBX500 Pinout for Matrix 400™
The table below gives the pinout of the CBX100/CBX500 terminal block connectors. Use this pinout when the
Matrix 400™ reader is connected by means of the CBX100/CBX500:
CBX100/500 Terminal Block Connectors
Power Outputs
Vdc Power Supply Input Voltage + +V Power Source - Outputs
GND Power Supply Input Voltage - -V Power Reference - Outputs
Earth Protection Earth Ground O1+ Output 1 +
O1- Output 1 -
Inputs
O2+ Output 2 +
+V Power Source – External Trigger O2- Output 2 -
I1A External Trigger A (polarity insensitive)
Auxiliary Interface
I1B External Trigger B (polarity insensitive) TX Auxiliary Interface TX
-V Power Reference – External Trigger RX Auxiliary Interface RX
+V Power Source – Inputs SGND Auxiliary Interface Reference
I2A Input 2 A (polarity insensitive)
ID-NET™
I2B Input 2 B (polarity insensitive) REF Network Reference
-V Power Reference – Inputs ID+ ID-NET™ network +
Shield
ID- ID-NET™ network -
Shield Network Cable Shield
Main Interface
RS232 RS485 Full-Duplex RS485 Half-Duplex
TX TX+ RTX+
RTS TX- RTX-
RX
*RX+
CTS
*RX-
SGND SGND SGND
* Do not leave floating, see Reference Manual for connection details.
CAUTION
Do not connect GND, SGND and REF to different (external) ground references. GND, SGND
and REF are internally connected through filtering circuitry which can be permanently
damaged if subjected to voltage drops over 0.8 Vdc.
Matrix 400™
Host
PG 6000
P.S.
*
* External Trigger or Presence Senso
r
(for One Shot or Phase Mode)
CBX
Main Interface
CAB-MS01
I/O, AUX