Matrix 400™ QUICK REFERENCE GUIDE 1 3 2 4 5 2 7 10 2 8 9 6 Figure A 1 Device Class Label 6 HMI X-PRESS™ Interface 2 Mounting Holes (12) 7 "POWER ON" LED 3 Lens Cover 8 Power - Serial Interfaces - I/O Connector 4 Lens (separate accessory) 9 Ethernet Connector (Ethernet Models Only) 5 Internal Illuminator (separate accessory) 10 Ethernet Connection LED (Ethernet Models Only) NOTE This manual illustrates a Stand Alone application.
MATRIX 400™ QUICK GUIDE UPDATES AND LANGUAGE AVAILABILITY UK/US The latest drivers and documentation updates for this product are available on Internet. Log on to: www.automation.datalogic.com I Su Internet sono disponibili le versioni aggiornate di driver e documentazione di questo prodotto. Collegarsi a: www.automation.datalogic.com F Les versions mises à jour de drivers et documentation de ce produit sont disponibles sur Internet. Cliquez sur : www.automation.datalogic.
MATRIX 400™ QUICK GUIDE STEP 1 – ASSEMBLE THE READER The first step to perform is to assemble the accessories that make up the Matrix 400™ reader. The lens and either an internal or an external illuminator must be used. This procedure shows an internal illuminator. Matrix 400™ must be disconnected from the power supply during this procedure. CAUTION 1. In a dust-free environment, remove the Matrix 400™ Lens Cover by unscrewing it. Do not touch the sensor aperture, lens glass or lens cover glass.
MATRIX 400™ QUICK GUIDE STEP 2 – CONNECT THE SYSTEM To connect the system in a Stand Alone configuration, you need the hardware indicated in Figure 2. In this layout the data is transmitted to the Host on the main serial interface. Data can also be transmitted on the RS232 auxiliary interface independently from the main interface selection. When One Shot or Phase Mode Operating mode is used, the reader is activated by an External Trigger (photoelectric sensor) when the object enters its reading zone.
MATRIX 400™ QUICK GUIDE 19-pin Connector Pinout for Matrix 400™ The table below gives the pinout of the 19-pin M16 male connector for connection to the power supply and input/output signals.
MATRIX 400™ QUICK GUIDE STEP 3 – MOUNT AND POSITION THE READER 1. To mount the Matrix 400™, use the mounting brackets to obtain the most suitable position for the reader. Two of the most common mounting configurations are shown in the figures below. Other mounting solutions are provided in the Matrix 400™ Reference Manual. Pitch Tilt Figure 4 –Positioning with Mounting Bracket (Back) Pitch Skew Figure 5 –Positioning with Mounting Bracket (Side) 2.
MATRIX 400™ QUICK GUIDE STEP 4 – FOCUS THE READER Matrix 400™ provides a built-in tool called Blue Diamonds™ to aid focusing the reader. The Blue Diamonds™ are accessed through the X-PRESS™ Interface. 1. Remove the lens cover in order to focus the reader. 2. Prepare the correct accessory lens for your application: a. Loosen the two Locking Knobs on the lens. b.
MATRIX 400™ QUICK GUIDE STEP 5 – CALIBRATE IMAGE DENSITY In order to function correctly to the fullest extent of its capabilities, Matrix 400™ must acquire information regarding image density or PPI (pixels per inch). This calibration takes place through the X-PRESS™ Interface and the Grade A Barcode Test Chart included in the package. This procedure is necessary for the first time installation, if the lens type is changed or if the focal distance is changed. LOCATE 1.
MATRIX 400™ QUICK GUIDE STEP 6 – X-PRESS™ CONFIGURATION Once Matrix 400™ has calibrated image density, you can configure it for optimal code reading relative to your application. This configuration can be performed either through the X-PRESS™ Interface or the VisiSet™ configuration program. LOCATE READY 1. Enter the Focus function by pressing and holding the X-PRESS™ push button until the Focus LED is on. green 2. Release the button to enter the Focus function. The Blue Diamonds™ turn on. green 3.
MATRIX 400™ QUICK GUIDE STEP 7 – INSTALLING VISISET™ CONFIGURATION PROGRAM VisiSet™ is a Datalogic reader configuration tool providing several important advantages: • Setup Wizard for rapid configuration and new users; • Defined configuration directly stored in the reader; • Communication protocol independent from the physical interface allowing to consider the reader as a remote object to be configured and monitored.
MATRIX 400™ QUICK GUIDE STEP 8 – CONFIGURATION USING SETUP WIZARD The Setup Wizard option is advised for rapid configuration or for new users. It allows reader configuration in a few easy steps. 1. Select the Setup Wizard button from the Main menu. 2. Remove the lens cover in order to focus the reader and loosen the two Locking Knobs on the lens. 1 Adjust the Focus ring to the "Far position" and the Diaphragm ring to the "F4" number setting which is the preferred setting for installation.
MATRIX 400™ QUICK GUIDE 3. Press the "Positioning" button. The reader continuously acquires images and gives visual feedback in the view image window. Select the largest code from the chart that completely fits into the view image window. Move the reader (or code) to center it. The code must be aligned across the X-axis reference line at the center of the FOV. See figure below. Press the Positioning button again to stop positioning. 3 4.
MATRIX 400™ QUICK GUIDE 5. Press the "Fine Focusing" button to activate the Fine Focusing Tool. The reader continuously acquires images and gives visual feedback on the focusing quality in the Focusing Tool window. Rotate the Focusing ring on the lens. The Current Focus Quality Bar (green) together with the vertical optimal focus line (green) increase together until the optimal focus is reached; the vertical optimal focus line stops.
MATRIX 400™ QUICK GUIDE Rotate the Focusing ring in the opposite direction. The Current Focus Quality Bar (green) increases towards the vertical optimal focus line (green) until the optimal focus is reached; the Current Focus Quality Bar touches the vertical optimal focus line (indicating the best focus). Tighten the Locking Knobs on the lens and press the "Close" button to return to the Setup Wizard. 6. Select a Code Setting Mode choice and press the "Code Setting" button.
MATRIX 400™ QUICK GUIDE 7. Place the application specific code in front of the reader at the same reading distance and repeat steps 3, 4, and 6. 3 4 6 Setup Result 8. Select a Saving Options choice and press the "Save" button. 9. Close the Setup Wizard. If your application has been configured using the VisiSet™ Setup Wizard, your reader is ready. If necessary you can use VisiSet™ for advanced reader configuration.
MATRIX 400™ QUICK GUIDE STEP 9 – TEST MODE Use a code suitable to your application to test the reading performance of the system. 1. Enter the Test function by pressing and holding the X-PRESS™ push button until the Test LED is on. 2. Release the button to enter the Test function. Once entered, the Bar Graph on the five LEDs is activated and if the reader starts reading codes the BarGraph shows the Good Read Rate. In case of no read condition, only the STATUS LED is on and blinks.
MATRIX 400™ QUICK GUIDE ADVANCED READER CONFIGURATION For further details on advanced product configuration, refer to the complete Reference Manual on the installation CD-ROM or downloadable from the web site through this link: www.automation.datalogic.com/matrix400.
MATRIX 400™ QUICK GUIDE APPENDIX X-PRESS™ is the intuitive Human Machine Interface designed to improve ease of installation and maintenance. Status and diagnostic information are clearly presented by means of the five colored LEDs, whereas the single push button gives immediate access to the following relevant functions: • Learn to self-detect and auto-configure for reading unknown codes • Setup to perform Exposure Time and Gain calibration.
MATRIX 400™ QUICK GUIDE OPTICAL ACCESSORY SELECTION Referring to Figure 20 and the formula below, use the data in the following table to calculate the FOV for your application. Viewing Angle Horizontal Viewing Angle Vertical Viewing Angle Diagonal Min Focus Distance mm 400 400-0x0 (SXGA) LNS-1109 9 mm LNS-1112 12.5 mm LNS-1116 16 mm LNS-1125 25 mm LNS-1135 35 mm LNS-1150 50 mm 48.5° 37° 28.5° 18.5° 13° 9° 39.5° 30° 23° 15° 10,5° 7° 60° 46.5° 36° 23.5° 16.5° 11.
MATRIX 400™ QUICK GUIDE TECHNICAL FEATURES ELECTRICAL FEATURES Power Supply Voltage Consumption Communication Interfaces Main - RS232 - RS485 full-duplex - RS485 half-duplex Auxiliary - RS232 ID-NET™ Ethernet (Ethernet Models only) Inputs Input 1(External Trigger) and Input 2 Outputs Output 1 and Output 2 2400 to 115200 bit/s 2400 to 115200 bit/s 2400 to 115200 bit/s 2400 to 115200 bit/s Up to 1MBaud 10/100 Mbit/s OPTICAL FEATURES 400 4xx-xxx models Image Sensor Image Format Frame Rate Pitch Tilt Light
MATRIX 400™ QUICK GUIDE CODE QUALITY VERIFICATION Standard ISO/IEC 16022 ISO/IEC 18004 ISO/IEC 15415 ISO/IEC 15416 AS9132A AIM DPM Supported Symbologies Data Matrix ECC 200 QR Code Data Matrix ECC 200, QR Code Code 128, Code 39, Interleaved 2 of 5, Codabar, Code 93, EAN-8/13, UPC-A/E Data Matrix ECC 200 Data Matrix ECC 200, QR Code USER INTERFACE LED Indicators Keypad Button Power, Ready, Good; Trigger; Com, Status, (Ethernet Network); (Green Spot) Configurable via VisiSet™ 109 [4.29] 123.2 [4.
MATRIX 400™ QUICK GUIDE PATENTS This product is covered by one or more of the following patents: U.S. patents: 6,512,218 B1; 6,616,039 B1; 6,808,114 B1; 6,997,385 B2; 7,102,116 B2; 7,282,688 B2 European patents: 999,514 B1; 1,014,292 B1; 1,128,315 B1. Additional patents pending.
MATRIX 400™ QUICK GUIDE SERIAL NUMBER REFERENCES Place the replicate, lens, illuminator and filter serial number labels here for reference. Some of this information can also be written in the Reader Information configuration parameters in the Miscellaneous folder in VisiSet™.