Instruction manual
MATRIX 400™ REFERENCE MANUAL
10
1
Learn
8. Enter the Learn function by pressing and holding
the X-PRESS™ push button until the Learn LED is
on.
9. Release the button to enter the Learn function.
The Learn LED will blink until the procedure is
completed.
The Learn procedure ends when the Image
Processing and Decoding parameters are
successfully saved in the reader memory, the
Learn LED will remain on continuously, the Green
Spot is activated and Matrix 400™ emits 3 high
pitched beeps
2
.
If the autolearning cannot be reached after a
timeout of about 3 (three) minutes Matrix 400™ will
exit without saving the parameters to memory, the
Learn LED will not
remain on continuously but it will
just stop blinking. In this case Matrix 400™ emits a
long low pitched beep.
10. Exit the Learn function by pressing the X-
PRESS™ push button once.
READY
green
green
y
ellow
y
ellow
red
SETUP
FOCUS
T
ES
T
LEARN
GOOD
T
RIGGER
COM
STATUS
Figure 14 – X-PRESS™ Interface:
Learn Function
NOTE
If you have used this procedure to configure Matrix 400™ go to step 9.
Reset Reader to Factory Default (Optional)
If it ever becomes necessary to reset the reader to the factory default values, you can
perform this procedure by holding the X-PRESS™ push button pressed while powering up
the reader. You must keep the X-PRESS™ push button pressed until the power up
sequence is completed (several seconds) and all LEDs blink simultaneously 3 times.
All LEDs remain on for about 1 second, then off for one second, the Configuration and
Environmental parameters are reset, and the status LED remains on. If connected through a
CBX500 with display module, the message "Default Set" is shown on the display.
2
The Learn procedure will not recognize Pharmacode symbologies.