Instruction manual
CBX ELECTRICAL CONNECTIONS 
4
4.2.1 RS232 Interface 
The RS232 interface can be used for Point-to-Point, Pass Through or Master/Slave 
connections. When it is connected to the host computer it allows both transmission of code 
data and reader configuration by VisiSet™. 
The following pins are used for RS232 interface connection: 
CBX100/500  Function 
TX Transmit Data 
RX Receive Data 
RTS  Request To Send 
CTS  Clear To Send 
SGND Signal Ground 
It is always advisable to use shielded cables. The overall maximum cable length must be 
less than 15 m (49.2 ft). 
SGND RXD  TXD 
CTS RTS 
USER INTERFACE
SGND TX  RX 
RTS CTS 
READER 
Figure 38 – RS232 Main Interface Connections Using Hardware Handshaking 
The RTS and CTS signals control data transmission and synchronize the connected devices. 
START
OF 
TRANSMISSION
END
OF 
TRANSMISSION
+ V
RTS
- V
+ V
TX DATA
- V
+ V
CTS
- V
DATA
TRANSMISSION
DATA
TRANSMISSION
C1
C2
C4
C3
C5
TRANSMISSION
STOPPED
ENABLED
DISABLED
ENABLED
IDLE
IDLE
Figure 39 - RS232 Control Signals 
If the RTS/CTS handshaking protocol is enabled, the Matrix 200™ activates the RTS output 
to indicate a message is to be transmitted. The receiving unit activates the CTS input to 
enable the transmission. 
35