Instruction manual
INTRODUCTION 
2
green 
green 
yellow 
yellow 
red 
green 
green 
yellow 
yellow 
red 
green 
green 
yellow 
yellow 
red 
 
Release button 
to enter Setup Mode 
Release button 
to enter Learn Mode 
 (cycle)
Release button 
to Exit 
Test Mode (Function 1) 
Once entered, the Bar Graph on the five LEDs is activated and if the imager starts reading 
codes the Bar-Graph shows the Good Read Rate. In case of a NO READ condition, only the 
Status
 LED is on and blinks. 
The Bar Graph has the following meaning: 
≥ 95% 
≥ 75% 
≥ 60% 
≥ 40% 
≥ 20% 
To exit the Test Mode, press the X-PRESS™ push button once. 
NOTE 
By default, the Test exits automatically after three minutes. 
Aim/Locate (Function 2) 
This function causes the blue ring to turn on. Since the blue ring is centered on the FOV it 
can be used to position the imager on the code. The Aim LED blinks to indicate this state. 
To exit the Aim/Locate Mode, press the X-PRESS™ push button once. The blue ring turns 
off. 