Operation Manual

2-36 Magellan
TM
8300/8400
3. Rotate the Interior Lift Handle up as shown in Figure 2-29 and
hook the fingers of both hands in the lift handles indicated. DO
NOT attempt to lift the unit using the plastic edges, scale frame, or
any features other than the lift handles.
Figure 2-27. Using the Lift Handles
4. Lower the unit into the counter opening, ensuring that none of the
cables are pinched, pierced or crimped.
5. View the bubble level (if present
1
) located on the scanner's spider
assembly to ensure the scanner is level. As shown in
Figure 2-28,
the air bubble should appear fully within the circle indicated. The
air bubble can touch the circle, but must not overlap it. Apply shims
beneath the scanner bottom or adjust the shelf to allow level installa-
tion.
Rear Lift
Handle
Interior Lift Handle
1. The bubble level is present only on certain models.