Operation Manual

A-4 Magellan
TM
8300/8400
Momentary (when
scanner is awake)
Increments volume
Press the push button momentarily to increase
speaker volume. When the loudest volume is
reached, a repeated press of the push button
cycles volume back to the lowest setting, then vol-
ume increases on subsequent press(es). Four vol-
ume levels are available.
Hold, then release
when the beeper
sounds
Increments tone
Press the push button for approximately 2 sec-
onds, then release. Each time this is done, the
beeper will sound at one of three tones. Stop when
the desired tone (high, medium or low) is sounded.
4 Seconds
Scanner Diagnostics
Mode
a
This mode allows system support personnel to
troubleshoot problems with the scanner. Upon
entering Scanner Diagnostic Mode, view the 7-
segment display to view Interface Type, Boot-
loader Version Number, Application Version Num-
ber and Configuration File Number. This mode is
used to determine if a scanner can read bar
codes. Press the button for eight seconds or cycle
power to exit Scanner Diagnostics Mode and reset
the scanner.
8 Seconds
Resets Scanner
b
Only system support personnel should perform a
reset.
a. Diagnostics Mode is meant for use by trained systems support personnel. Users should not need to ini-
tiate this function under normal circumstances.
b. Users should not perform scanner resets except under the direction of trained systems support person-
nel.
Table A-2. Volume/Tone Push Button Functions (Continued)
PRESS
DURATION
FUNCTION COMMENT