Operation Manual
Calibrating the Scale (Pounds & Kilograms)
Product Reference Guide 5-5
Figure 5-1. Calibration Switch Access
4. Press and release the Calibration Switch to place the scanner/scale in
Calibration Mode. (The scanner/scale will sound a a series of rapid
beeps indicating it is in Calibration Mode.) If the motor was spin-
ning when you initiated Calibration Mode, the motor will stop and
the Yellow LED will begin flashing indicating the scale is in Calibra-
tion Mode. The Remote Display (if one is present) will show the mes-
sage “ESCL” (empty scale).
5. Reinstall the weigh platter.
6. Press the Zero Push Button. The Yellow LED will go out for
approximately 10 seconds (or less). If one is present, the Remote Dis-
play will alternately display and until the scale
is ready to proceed.
7. When the scale is ready, the Yellow LED will begin blinking again.
The Remote Display (if one is present) will show the message “Ad20
(add twenty pounds)” or “Ad10 (add ten kilograms).” (The scanner/
scale will also sound one tone if the scale is weighing in kilograms or
two tones for pounds.) Place the correct weight (twenty pounds for
calibration in pounds, or ten kilograms for metric calibration) from
the Field Standard Weight set on the center of the weighing area and
press the Zero Push Button again.
Spider
Calibration
Switch