Instruction manual
Input Wiring M-Series Processor and Camera Guide
Datalogic Automation, Inc. 4-2
Interrupt-driven inputs are edge-triggered and the duration of the input pulse must be longer than the debounce time. The
active trigger edge (rising, falling, or both), input pulse duration, and debounce, are all configured in the Vision Program
Manager Settings tab.
This table describes the input characteristics.
Input Wiring
The diagrams below show two ways to wire a sensor to a general purpose or event input.
Note: All connections to inputs must be made using properly grounded shielded cable.
All inputs must be wired as either sinking or sourcing, they cannot be mixed. There is only one “Input Common” connec-
tion for all the inputs.
General Purpose Input Circuit (Sinking)
General Purpose Input Circuit (Sourcing)
Input Resistance
(nominal)
Input
Voltage
Turn On
Voltage
Turn Off
Voltage
Isolated
Voltage
1.2k @ 0.5 W 0-24 Vdc >3 Vdc < 0.8 Vdc 2500 Vrms