Instruction manual
M-Series Processor and Camera Guide Processor Specifications
1-3 Datalogic Automation, Inc..
7. To avoid injury, never open the case. Opening the case or removing the tamper-proof sticker will void the product
warranty.
Service Personnel Only - Caution: Risk of explosion if battery is replaced by an incorrect type. Dispose of used
batteries according to battery maker’s instructions.
Processor Specifications
This section lists the general operating specifications for the M-Series Processor. More detailed specifications are listed in
other appropriate sections of this manual. Each of the M-Series cameras has different operating specifications. See “M-
Series Cameras” on page 3-1 for details.
*Note: The MX20 and MX40 processors require approximately 3.5A @ 24VDC. We recommend using a
24 VDC power supply capable of providing 3.5A current. The M-Series processors run most effi-
ciently at this voltage which is commonly used in many manufacturing environments.
The MX80 processor requires approximately 5A @ 24VDC. We recommend using a 24 VDC
power supply capable of providing 5A current.This voltage is commonly used in many manufactur-
ing environments.
**The MX20 processor can accommodate a maximum of two cameras. The maximum image size of each camera is two
Megapixels. (The calculation is: maximum width in pixels * maximum height in pixels < 2,500,000.)
Setting Up the System
WARNING: To avoid damage to your unit, never plug in or unplug any cables when the unit power is on. Always turn
off the power supply first before making any cable changes.
Processor Operating Environment
Model MX20** and MX40 MX80
Dimensions 7.8 w x 3.3 h x 6.5 d (in)
200 w x 85 h x 165 d (mm)
9.06 w x 3.23 h x 8.11 d (in)
230 w x 82 h X 206 d (mm)
Weight 4.8 lb. (2.16 kg) 6.61 lb. (3 kg)
Input Power*
10 to 30VDC , Min 3.5A 10 to 30VDC , Min 5A
Temperature
Humidity
0° to +55° C (+32° to +131° F)
0% to 90% (non-condensing)
0° to +55° C (+32° to +131° F)
0% to 90% (non-condensing)
Safety
Compliance
CE/FCC, RoHs, IP30, UL
(MX20 UL Pending)
CE/FCC, RoHs, IP30, UL
Minimum
Software
Version
MX20 - 10.5.0
MX40 - 10.0.0
10.4.0
Protection
Class
IP50 IP50