Instruction manual
Dalsa Cameras M-Series Processor and Camera Guide
Datalogic Automation, Inc. 3-40
*NOTE: To operate these cameras, an MX-Series processor with Windows 7 64-bit operating system is required. The
MX80 processor with 8 Gb of memory is required when using two of these cameras on one system.
Dalsa Camera Connection
This camera uses three cables, one for Ethernet, one for power, and one for I/O signals. For the Ethernet connection, use
cable 606-0677-xx.
WARNING: THESE CAMERAS REQUIRE +12 VDC POWER. OUR CAMERA AND OTHER THIRD-PARTY
CAMERA REQUIREMENTS ARE DIFFERENT. USE CAUTION WHEN CONNECTING POWER TO THESE
CAMERAS.
Power Connection
To connect power, use the optional 6 pin Hirose pigtail cable (606-0672-xx). Do NOT use the M1xx terminal block (661-
0399) because it has internal pullup resistors.
I/O Connection
To connect I/O signals, use a terminal block (248-0136) with the optional 15 pin HD cable (606-0568-xx).
SG-14-01K40 1k 14 36 10.6.0
SG-14-01K80 1k 14 68 10.6.0
SG-14-02K40 2k 14 18 10.6.0
SG-14-02K80 2k 14 36 10.6.0
SG-14-04K80 4k 10 18.5 10.6.0
Power Cable
Pin Number and Color
Signal Name Notes
1 (Blue)
2 (Orange)
3 (Green)
Camera Power Min +12 VDC to Max +15 VDC @ 750
mA Max
4 (Wht w/Grn)
5 (Wht w/Org)
6 (Wht w/Blu)
Camera Ground
I/O Terminal
Block Number
Signal Name Notes
1
Input 0 +
Single Line Trigger
OR
Phase A Line Trigger
(Quadrature Encoder)
See Note 2 below and
“Dalsa Scan Direction” on
page 3-41
As sinking input
Off 0 to +0.66 VDC
On: +2.6 to +5 VDC
As sourcing input
Off: +2.6 to +5 VDC
On 0 to +0.66 VDC
Maximum: +5 VDC
2
Input 0 -
LVDS mode differential See Note 1 below