Instruction manual

Basler Cameras M-Series Processor and Camera Guide
Datalogic Automation, Inc. 3-28
Basler Cameras
Basler Camera Connection
WARNING: THESE CAMERAS REQUIRE +12 VDC POWER. OUR CAMERA AND
OTHER THIRD-PARTY CAMERA REQUIREMENTS ARE DIFFERENT. USE CAU-
TION WHEN CONNECTING POWER TO THESE CAMERAS.
To connect power, trigger signals, and strobe outputs for these Basler camera models, use
cable 606-0673-xx (12-pin Hirose Male to HD-15) with terminal block 661-0400.
Model
(GigE)
Resolution
(Megapixels)
Color Image
Horizontal
Image Vertical FPS
(approx)
Minimum Software
Version Required
avA1000-100gm
avA1000-100gc
1No
Yes
1024 1024 101 10.3.0
avA1600-50gm
avA1600-50gc
1No
Yes
1600 1200 55 10.3.0
avA1900-50gm
avA1900-50gc
2No
Yes
1920 1080 51 10.3.0
avA2300-25gm
avA2300-25gc
3No
Yes
2239 1750 26 10.3.0
Terminal Signal Name Notes
Camera Power Ground Camera Ground
I/O Ground I/O Ground
Camera Power +VDC Camera Power +12 VDC recommended @ 500 mA Max
Maximum: +13.2 VDC
Output +VCC Power for Strobe Trigger Out +3.3 to +24 VDC; 50 mA Max
Maximum: +30 VDC
Input 2 Pullup +VCC DO NOT USE Not Currently Supported
Trigger Pullup +VCC Trigger In Pullup - use if Trig-
ger In needs sourcing input
Recommended: +24 VDC
Trigger In Camera Trigger In (see Note
1 below)
0 to +24 VDC recommended
Maximum +30 VDC
As sinking input
Off: 0 to +1.4 VDC
On: +2.2 to +24 VDC; 5 to 15 ma
As sourcing input (see Trigger Pullup
+VCC)
Off: +2.2 to +24 VDC; 5 to 15 ma
On: 0 to +1.4 VDC
Input 2 DO NOT USE Not Currently Supported
Strobe Trigger Out Trigger Out to Strobe (see
Note 2 below)
DO NOT APPLY GROUND DIRECTLY
TO THIS OUTPUT.
Output 2 DO NOT USE Not Currently Supported
Output 3 DO NOT USE Not Currently Supported