Instruction manual

Third-party Cameras M-Series Processor and Camera Guide
Datalogic Automation, Inc. 3-20
Third-party Cameras
The M-Series Processor and Impact Software support only the third-party cameras listed in this section. This information,
including power and trigger signal connections, are provided by us as a convenience. You must purchase a license from us
to connect a third-party camera to the M-Series processor.
We assume no responsibility for the accuracy or timeliness of this third-party camera information.
For complete details and the most accurate specifications for these cameras, consult the manufac-
turers documentation.
JAI Cameras
NOTE: See “JAI Camera I/O Signals” on page 3-27 for important information about camera and strobe signals.
*See “Color shading support” on page 3-26 for special camera configuration settings.
JAI Camera Connection
To connect JAI camera power, trigger signals, and strobe outputs, use cable 606-0673-xx
(12-pin to HD-15) with terminal block 661-0402.
NOTE: Do NOT use terminal block 248-0141 to connect this camera. It will NOT provide
the correct signal levels.
WARNING: THE POWER AND GROUND CONNECTIONS FOR THIS CAMERA
ARE DIFFERENT FROM OUR CAMERAS AND OTHER THIRD-PARTY CAM-
ERAS. USE CAUTION WHEN CONNECTING POWER TO THESE CAMERAS.
Model
(GigE)
Resolution
(Megapixels)
Color Image
Horizontal
Image Vertical Minimum Software
Version Required
AT-200GE* 2 Yes 1624 1236 10.3.0
AM-800GE 8 No 3296 2472 10.3.0
CM-140GE*
1.4 Yes
(3 CCD)
1392 1040 10.5.0
CM-140GE-UV
1.4 Ultraviolet 1392 1040 10.2.0
CM-030GE-RH
(remote head)
0.3 No 659 494 10.2.0
Terminal Signal Name Notes
Camera Power
Ground
Camera Ground