Instruction manual

M5xx Camera Connection M-Series Processor and Camera Guide
Datalogic Automation, Inc. 3-16
M5xx Camera Connection
To connect the M5xx, use terminal block 661-0401 with cable 606-0673-xx (12-pin to HD-15
camera I/O) and cable 606-0674-xx (6 pin to DB9 camera power). For details about program-
ming the Line Trigger, refer to the Impact Reference Guide (843-0093)
NOTE: Do NOT use the M2xx/M3xx terminal block (661-0400) or M1xx block (661-0399) to
connect this camera. They will NOT provide the correct signal levels.
Terminal Signal Name Notes
Camera Power Ground Camera Ground See Note 1 Below
I/O Ground I/O Ground See Note 1 Below
Camera Power
+12VDC
Camera Power +12 VDC (+-10%) @ 700 mA Max
Input 1 - No Connection DO NOT USE
Input 1 + Frame Start Trigger As sinking input
Off 0 to +0.8 VDC
On: +2.0 to +5 VDC
As sourcing input (see Input 1 Pullup)
Off: +2.0 to +5 VDC
On 0 to +0.8 VDC
Maximum: +5 VDC
Input 2 - No Connection DO NOT USE
Input 2 + Single Line Trigger
OR
Phase A Line Trigger
(Quadrature Encoder)
As sinking input
Off 0 to +0.8 VDC
On: +2.0 to +5 VDC
As sourcing input (see Input 2 Pullup)
Off: +2.0 to +5 VDC
On 0 to +0.8 VDC
Maximum: +5 VDC
Input 3 - No Connection DO NOT USE
Input 3 + Phase B Line Trigger
(Quadrature Encoder)
As sinking input
Off 0 to +0.8 VDC
On: +2.0 to +5 VDC
As sourcing input (see Input 3 Pullup)
Off: +2.0 to +5 VDC
On 0 to +0.8 VDC
Maximum: +5 VDC
Output 1 - Not Currently Supported DO NOT USE
Output 1 + Not Currently Supported DO NOT USE
Output 2 - Not Currently Supported DO NOT USE
Output 2 + Not Currently Supported DO NOT USE
Input 1 Pullup +5VDC Frame Start Trigger Pullup -
use if Input 1 needs sourcing
input
Maximum: +5 VDC
Input 2 Pullup +5VDC Line Trigger Pullup - use if
Input 2 needs sourcing input
Maximum: +5 VDC