Instruction manual
M-Series Processor and Camera Guide M1xx Camera Connection
3-11 Datalogic Automation, Inc.
ger than you would on a M2xx to account for the delays. The shutter time must then be set a little longer than the strobe
time.
Time Delay Rise (TDR) = 40 us
Rise Time (RT) = 20 us to 70 us
Time Delay Fall (TDF) = 0.6 us
Fall Time (FT) = 0.7 us to 1.4 us