Instruction manual
MX80 Processor Power Supply Connection M-Series Processor and Camera Guide
Datalogic Automation, Inc. 2-10
MX80 Processor Power Supply Connection
Warning: To avoid electrical shock, disconnect all power to the power supply before working on it.
Avertissement: Pour éviter le choc électrique, débranchez toute la puissance à l'alimentation d'énergie avant de tra-
vailler à lui.
The MX80 power input uses the supplied connector. Wire the power supply cable to the connector, then plug it into the
power connector on the rear of the processor. The ground terminal on the power input must be connected to the power
supply’s grounded chassis/enclosure. This connection is needed to insure electromagnetic compliance and proper opera-
tion.
*Note: The MX80 processor requires approximately 5A @ 24VDC. We recommend using a 24
VDC power supply capable of providing 5A current. This voltage is commonly used in
many manufacturing environments.
Connect V+ terminal to Power Supply 10-30VDC*
Connect V- terminal to Power Supply Minus
Connect GND terminal to Power Supply Circuit Ground
GND V-V+
Power Connector
POWER INPUT
10-30VDC*