Instruction manual
M-Series Processor and Camera Guide MX20 and MX40 Processor Power Supply Connection
2-9 Datalogic Automation, Inc.
MX20 and MX40 Processor Power Supply Connection
Warning: To avoid electrical shock, disconnect all power to the power supply before working on it.
Avertissement: Pour éviter le choc électrique, débranchez toute la puissance à l'alimentation d'énergie avant de tra-
vailler à lui.
The MX20 and MX40 power inputs use standard spade terminals to connect the power supply. The ground terminal on the
power input must be connected to the power supply’s grounded chassis/enclosure. This connection is needed to insure
electromagnetic compliance and proper operation.
*Note: The MX20 and MX40 processors require approximately 3.5A @ 24VDC. We recommend
using a 24 VDC power supply capable of providing 3.5A current. The M-Series processor
runs most efficiently at this voltage which is commonly used in many manufacturing envi-
ronments.
Connect + terminal to Power Supply 10-30VDC*
Connect - terminal to Power Supply Minus
Connect Ground terminal to Power Supply Circuit Ground
123
2
1
3
Power Connector