Safety Instructions
Warning: There are no user-serviceable parts inside the device. To avoid electrical shock, never open the case.
Opening the case or removing the tamper-proof sticker will void the product warranty.
Attention: Il n'ya pas de pièces réparables par l'utilisateur à l'intérieur du matériel. Pour éviter un choc électrique,
n'ouvrez jamais le boîtier. L'ouverture du boîtier ou de retirer l'étiquette inviolable annulera la garantie du produit.
Mounting Warning: Mount the processor with the front or back of the unit facing down. For safety, do NOT
mount the processor with the filter side down. Mounting with the fan side down is acceptable only if approved
metal screen filters have been installed in all fan exhausts.
Make sure heavy equipment is loaded evenly in the rack to avoid a hazardous condition. The rack should safely support
the combined weight of all the equipment it supports.
Before the system is connected to the supply circuit, be sure to check equipment nameplate ratings to avoid overloading
circuits. Overloading may damage over-current protection devices and supply wiring.
Be sure to maintain reliable grounding for rack-mounting equipment. Pay particular attention to supply connections.
Slots and openings in the cabinet are provided for ventilation. To ensure sufficient air circulation for reliable system
operation, and to prevent overheating, maintain a minimum of 1.5 inches (38.1 mm) of clearance on the top and sides
of the cabinet and between M-Series Processors.
This equipment is to be powered by a Listed power supply for the U.S. and Canada, or a power supply that meets the
requirements for use where either IEC60950 or EN60950 is applicable.
To ensure safe operation, the system power must be properly grounded. If the unit is mounted within a rack, verify that
it is reliably connected to electrical ground. The ground terminal on the power input must be connected to the grounded
chassis/enclosure of the power supply. This insures electromagnetic compliance and proper operation.
The ITE is to be connected only to PoE networks that do not route outside the plant.
Metal Screen Filter Installed
Metal Screen Filter NOT Installed.
Do NOT mount fan side down