Instruction manual

JAI Cameras (Older Terminal Blocks) M-Series Processor and Camera Guide
Datalogic Automation, Inc. 6-16
JAI Cameras (Older Terminal Blocks)
JAI Camera Connection (Older Terminal
Blocks)
Camera power, trigger signal, and strobe trigger can be connected to the camera using one of two
methods: a terminal block with a cable or an unterminated cable. Use a terminal block (248-0136)
with the optional Hirose 12-pin to HD-15 camera cable (606-0673-xx). Without a terminal block,
use the optional Hirose 12-pin to unterminated cable (part number 606-0671-xx).
NOTE: Do NOT use terminal block 248-0141 to connect this camera. It will NOT provide the cor-
rect signal levels.
WARNING: THE POWER AND GROUND CONNECTIONS FOR THIS CAMERA ARE DIFFERENT FROM
OUR CAMERAS AND OTHER THIRD-PARTY CAMERAS. USE CAUTION WHEN CONNECTING POWER
TO THESE CAMERAS.
Terminal Color Signal Name Notes
1 Wht/Blu Camera Power Ground See Note 1 below
2 Wht/Org Camera Power VCC CM-140GE-UV and CM-030-GE-RH
+12 VDC @ 350 mA Max (4.1 W)
Maximum: +13.2 VDC
AM-800GE
+12VDC to +24VDC ±10%, 8.16W (at normal,
Full resolution, DC+12V)
AT-200GE
+10.8VDC to +26.4VDC, 0.67 A (Typical , Full
frame, DC +12V in)
See Note 1 below
3 Wht/Brn DO NOT USE
4 Brn/Wht DO NOT USE
5 Wht/Grn Camera Trigger -
6 Wht/Gry Camera Trigger + +0 to +24 VDC
Off: 0 to + 1.4 VDC
On: +3.3 to + 24 VDC
Maximum: +24 VDC
7 Gry/Wht Strobe Trigger - 270 Ohm 2W resistor between Gry/Wht wire and
Strobe Power Ground
8 Blu/Wht Strobe Trigger + +5 to +24 VDC
Maximum: +24 VDC
9 Org/Wht DO NOT USE
10 Grn/Wht DO NOT USE
11 Red/Blu Camera Power VCC See Note 1 below
12 Blu/Red Camera Power Ground See Note 1 below