Installation manual
INSTALLATION
15
2
20 mA Current Loop (INT-24 Accessory Only)
When the INT-24 accessory board is installed, the DS4600A is equipped with a
20 mA active current loop interface.
The following pins of the 25-pin connector are used for the connections:
Pin Name Function
4 CLOUT- current loop output
5 CLIN- current loop input
7 SGND Main signal ground main interface
DS4600A USER INTERFACE
MAX. 300 METERS
4 C.L. OUT -
7 SGND Main
GND
I = 20 mA
5 C.L. IN -
I = 20 mA
+
+
Figure 11 - 20 mA Active C.L. Connections
For 20 mA passive current loop interface connections, contact your local Datalogic
representative.