User Manual

Enter/Exit Programming Mode Standard 2 of 5
176 Heron™ HD3430
Standard 2 of 5 Set Length 1
This feature specifies one of the bar code lengths for Standard 2 of 5 Length
Control on page 175. Length 1 is the minimum label length if in Variable Length
on page 175 Mode, or the first fixed length if in Fixed Length on page 175
Mode. Length includes the bar cod
e’s check and data characters.
The length can be set from 1 to 50 characters. See "Set Length 1" on page 260
for more detailed programming in
structions.
Select Standard 2 of 5 Length 1 Setting
To configure this feature, scan the ENTER/EXIT bar code
above, then the bar code at left followed by digits from
the Alphanumeric characters in
Appendix D, Key-
pad
representing your desired character(s). End by
scanning the ENTER/EXIT bar code again.
Make a mistake? Scan the CANCEL bar code to abort and
not save
the entry string. You can then start again at the
beginning.
CANCEL
DEFAULT
08 = Length 1 is 8 Characters
$CS2L1
~