Specifications
GWY-01-DNT-01 MANUAL – REV. 02        APPENDIX A: 
      TECHNICAL SPECIFICATIONS 
       PAGE 56 OF 67   
APPENDIX A: 
TECHNICAL SPECIFICATIONS 
ELECTRICAL 
Supply Voltage 
10~30VDC 
Power Consumption 
120mA @ 24VDC (2.88W) 
COMMUNICATION 
Communication Interfaces 
Point-to-Point: RS485 
Multi-drop: Subnet16, MUX32  
DeviceNet 
RFID Interface: 
Gateway HF-Series RFID System 
RF Output Power: 
1W 
Air Protocols 
ISO 15693, ISO 14443 A 
Air Protocol Speed: 
26.5kBaud / 106kBaud with CRC error detection 
RS485 Baud Rates 
9600 (default), 19.2k, 38.4k, 57.6k, 115.2k 
MECHANICAL 
Dimensions 
76mm x 89mm x 33mm 
Weight 
.24 KG (.53 lbs) 
Enclosure: 
Stainless Steel 304 (18-8) 
ENVIRONMENTAL 
Operating Temperature 
-20° to 50°C (-4° to 122°F), 
Storage Temperature 
-40° to 85°C (-40° to 185°) 
Humidity 
90% Non-Condensing 
Protection Class 
IP30 
Shock Resistance 
IEC 68-2-27 Test EA 30g, 11 milliseconds, 3 shocks 
each axis 
Vibration Resistance 
IEC 68-2-6 Test FC 1.5mm; 10 to 55Hz; 
2 hours each axis 
NOTE: Specifications are subject to change without notice. 