Specifications
GWY-01-DNT-01 MANUAL – REV. 02        CHAPTER 1: 
       GETTING STARTED 
       PAGE 13 OF 67   
1.5  I
NSTALLATION GUIDELINES 
1.5.1  Hardware Requirements 
The following components are required for a complete Subnet16 RFID system: 
  One Subnet16 DeviceNet Gateway Interface Module 
  One ControlLogix PLC or other DeviceNet-capable host 
  One to 16 RS485-based RFID controllers (Cobalt or HF-0405-Series) 
  Adequate length cabling, connectors and terminators 
  Sufficient power, supplied via DeviceNet network cabling, capable of 
powering the Gateway and its RFID controllers 
  EMS’ HMS-Series, LRP-Series or T-Series RFID tags 
1.5.2  Installation Precautions 
 Route cables away from motors, solenoids, unshielded cables and any wiring 
that carries high voltage or high current. 
 Review the power requirements of your RFID network and provide a suitable 
power supply. 
 The Gateway is designed to withstand 8kV of direct electro-static discharge 
(ESD) and 15kV of air gap discharge. However, it is not uncommon for some 
applications to generate considerably higher ESD levels. Always use 
adequate ESD prevention measures to dissipate potentially high voltages. 
  Avoid mounting the Gateway or its RFID controllers near sources of EMI 
(electro-magnetic interference) or near devices that generate high ESD 
levels. 
  Perform a test phase by constructing a small scale, independent network that 
includes only the essential devices required to test your RFID application 
(use EMS approved Subnet16 cables and accessories). 
  Cables should only cross at perpendicular intersections. 
1.5.3  Network & Power Considerations 
•  Refer to the network diagrams in Appendix C. Choose the network 
architecture (ThickNet vs. ThinNet) that best suits your RFID requirements. 
•  Construct your chosen network using only EMS approved Subnet16 cables, 
Drop-T connectors, Terminating Resistors and accessories. 
•  Review the power requirements of your RFID network and provide a suitable 
power supply. (See Appendix B
 for power supplies offered by EMS). 
IMPORTANT NOTE: It is strongly recommended that power be applied directly to the 
Subnet16 
TM
 Network trunk and distributed through drop cables to the Gateway and 
RFID controllers.