Specifications

Product Reference Guide 25
Chapter 4
Configuration Using Code Symbols
This section describes the programming method of using configuration code symbols to
program your reader. By using the Gryphon D432/D412Plus reader to read/decode these
special configuration symbols, you can configure, and obtain information from its system
software.
When you are reading configuration code symbols,
carefully aim the Gryphon D432/D412Plus
2D reader to avoid reading adjacent symbols.
The configuration code symbols in this chapter are divided into logical sections according to the
type
of configuration required, (RS-232 configuration, Code selection, etc.). If arguments are
required with a command, you can read additional code labels (typically digits) from
Appendix D.
To configure your reader:
1. Read the Enter Configuration code ONC
E, available on top of each page.
2. Modify the desired parameters in one or more sections by reading the parameter code and
se
lecting the value from the Hex/Numeric table (see Appendix D) or
by following the
given procedures.
3. Read the Exit and Save Configuration code ONCE, av
ailable on top of each page.
Example for step 3
To set the maximum length of characters in a Code 39 barcode symbol that the reader will
decode t
o 32:
first read the Maximum Length symbol for Code 39 on page 61
then read the symbol for the digit "3" and lastly the symbol for the digit "2" in
Appendix D.
USA Driver License Parsing is a feature not covered in this manual. For more information, reference the “USA Driver License Parsing