Specifications

References
310
Gryphonâ„¢ I GD4100/GM4100/GBT4100/L GD4300
Table 39
STEP ACTION EXAMPLES
1. Scan the ENTER/EXIT barcode
(Scanner enters Programming Mode)
2.
Determine placement of the
Label ID charac
ters BEFORE or
AFTER with regard to scanned
data using
Label ID
Control, starting on page 82
Enable as Prefix Enable as Suffix Enable as Prefix Enable as Suffix
3.
Scan the barcode selecting the
symbology type
you wish to
designate label ID characters
for using
Label ID Symbology
Selection, starting on page 83
.
DataBar
Omnidirectional
Code 39 Interleaved 2 of 5 Code 32
4.
Custom Label ID example
(desired char
acters):
D B * = C 3 + P H
5.
Find hex equivalents from the
ASCII Chart
(inside back
cover), then scan in these
digit
s/characters using the
barcodes in the section:
Keypad, starting on page 351
.
If you make a mistake before
the last
character, scan the
CANCEL barcode to abort and
not save the entry string. You
can then start again at the
beginning.
44 42 2A 3D 43 33 2B 50 48
6. Scan the ENTER/EXIT barcode
(Scanner exits Label ID entry)
7.
Scan the ENTER/EXIT barcode
once again
(Scanner exits Programming Mode)
Result:
DB*[barcode
data]
[barcode
data]=C3
+[barcode data] [barcode data]PH
. Label ID Examples