Gryphon™ Family General Purpose Handheld Linear Imager or Laser Bar Code Readers Gryphon I GD4100/GM4100 Gryphon BT4100/ L GD4300 Product Reference Guide
Datalogic Scanning, Inc. 959 Terry Street Eugene, Oregon 97402 USA Telephone: (541) 683-5700 Fax: (541) 345-7140 An Unpublished Work - All rights reserved. No part of the contents of this documentation or the procedures described therein may be reproduced or transmitted in any form or by any means without prior written permission of Datalogic Scanning, Inc. or its subsidiaries or affiliates ("Datalogic" or “Datalogic Scanning”).
Table of Contents INTRODUCTION ................................................................................................................................................................................ 9 About this Manual .......................................................................................................................................................................................... 9 Overview ......................................................................................
Contents Beep On Not on File .......................................................................................................................................................................................................48 ACK NAK Options ............................................................................................................................................................................................................49 ACK Character ............................................
Contents Stand Mode Sensitivity .............................................................................................................................................................................................. 104 Scanning Active Time ................................................................................................................................................................................................. 104 Flash On Time ....................................................
Contents Code 39 Stitching ......................................................................................................................................................................................................... 147 CODE 32 (ITAL PHARMACEUTICAL CODE) ...............................................................................................................................148 Code 32 Enable/Disable ..........................................................................................
Contents Standard 2 of 5 Stitching ........................................................................................................................................................................................... 183 INDUSTRIAL 2 OF 5 ....................................................................................................................................................................184 Industrial 2 of 5 Enable/Disable ..................................................................
Contents GS1 DataBar™ Expanded Enable/Disable ............................................................................................................................................................ 223 GS1 DataBar™ Expanded GS1-128 Emulation ................................................................................................................................................... 223 GS1 DataBar™ Expanded Minimum Reads .............................................................................
Contents Leash Alarm .................................................................................................................................................................................................................... 262 CONFIGURATION UPDATES ......................................................................................................................................................264 Automatic Configuration Update ...................................................................
Contents Label Gone Timeout ......................................................................................................................................................................................................................... 312 Good Read LED Duration ................................................................................................................................................................................................................ 313 Scanning Features ........
Chapter 1 Introduction About this Manual This Product Reference Guide (PRG) is provided for users seeking advanced technical information, including connection, programming, maintenance and specifications. The Quick Reference Guide (QRG) and other publications associated with this product are downloadable free of charge from the website listed on the back cover of this manual.
Introduction Manual Conventions The following conventions are used in this document: The symbols listed below are used in this manual to notify the reader of key issues or procedures that must be observed when using the reader: Notes contain information necessary for properly diagnosing, repairing and operating the reader. The CAUTION symbol advises you of actions that could damage equipment or property.
About the Reader About the Reader Typically, units are factory-programmed for the most common terminal and communications settings. If you need to modify any programmable settings, custom configuration can be accomplished by scanning the programming barcodes within this guide. Several models of the Gryphon are available, and are covered in this manual: • Gryphon I GD4100 - Corded linear imager barcode reader • Gryphon I GM4100 - Cordless linear imager barcode reader with Datalogic STAR™.
Introduction The following table describes the significance of each LED: LED STATUS Yellow On = Base is powered Power on / Data Yellow Blinking = Base receives data and commands from the Host or the Reader. Charging Red On = Battery charging is in progress. Charge completed Green On = the Battery is completely charged. Charging + Charge completed Red and Green Blinking together = the Reader is not correctly placed onto the Base.
BC40XX UV Counterfeit Detection The Counterfeit Detector is based on UV fluorescent emission. Real banknotes under ultraviolet rays usually absorb the UV light and will show special marks made with fluorescent inks. On the other hand, most counterfeit banknotes only reflect the UV lights, without showing fluorescent marks. To use: 1. Quickly press the Base button to light the UV LEDs. 2. Hold the item to be verified under the LED lights to ensure that the special fluorescent marks are visible. 3.
Introduction Display The Gryphon GM4100 is available with an optional Display. The Display features 4 lines and 16 characters, and offers icons and three additional keys to allow a better interaction with a remote host. Fonts, contrast, backlight and other parameters can be configured for the Display. See Display Features on page 274 and Message Formatting on page 323 for more information. Figure 2.
Battery Safety WARNING In the event the battery pack leaks and the fluid gets into your eye, do not rub the eye. Rinse well with water and immediately seek medical care. If left untreated, the battery fluid could cause damage to the eye. • • • CAUTION • • • • • • • • Always charge the battery at 32° – 104°F (0° - 40°C) temperature range. Use only the authorized power supplies, battery pack, chargers, and docks supplied by your Datalogic reseller.
Introduction Programming the Reader Configuration Methods Programming Barcodes The reader is factory-configured with a standard set of default features. After scanning the interface barcode, you can select other options and customize your reader through use of the instructions and programming barcode labels available in the corresponding features section for your interface. Customizable settings for many features are found in "Configuration Using Barcodes" starting on page 37.
Chapter 2 Setup Unpacking Check carefully to ensure the reader and any accessories ordered are present and undamaged. If any damage occurred during shipment, contact Datalogic Technical Support. Information is shown on page 10. KEEP THE PACKAGING. Should the unit ever require service, it should be returned in its original shipping container.
Setup Installing the Interface Cable For Corded versions, connect the reader cable by inserting the cable into the handle as shown in Figure 3. To remove it, insert a paper clip into the release aperture, then unplug the cable. Figure 3. Connect/disconnect the cable RS-232 Serial Connection Turn off power to the terminal/PC and connect the reader to the terminal/PC serial port via the RS-232 cable as shown in Figure 4.
Installing the Interface Cable Keyboard Wedge Connection The Keyboard Wedge cable has a ‘Y’ connection from the reader. Connect the female to the male end from the keyboard and the remaining end at the keyboard port at the terminal/PC. Reference Figure 5. Figure 5. Keyboard Wedge Interface connection USB Connection Connect the reader to a USB port on the terminal/PC using the correct USB cable for the interface type you ordered. Reference Figure 6. Figure 6.
Setup B Figure 7. Other Interface Connections US Ke or... IB M W yboa ed rd ge or... Specific cables are required for connection to different hosts. The connectors illustrated above are examples only. Actual connectors may vary from those illustrated, but the steps to connect the reader remain the same. RF Models The power supply connects directly to the base (not on the cable's jack) for all configurations.
Configuring the Base Station Changing the Base Station Position The base station is configured by installing one of two sets of mechanical parts that come with the cordless kit. The default mounts (shown below) provide three options: vertical (wall) mounting, standing (45°), or horizontal mounting with a higher mechanical retention of the scanner. Use the other mounts only for horizontal mounting, with lower retention of the scanner.
Setup 3. The stand can now be repositioned in either horizontal or standing position. Horizontal Standing Connecting the Base Station Figure 8 shows how to connect the Base Station to a terminal, PC or other host device. Turn off the host before connection and consult the manual for that equipment (if necessary) before proceeding. Connect the interface cable before applying power to the Base Station. The Gryphon GBT4100 can be set up to require a PIN code when connecting to the host.
Configuring the Base Station Figure 8. Connecting the Base Station Wall plug Connector I/F Cable AC/DC Adapter DC Power Cord Base Station Securing the DC Power Cord (Optional) The DC power cord for the adapter can be secured to the bottom of the base in order to maximize the mechanical retention of the cable itself. The routing of the power cord can be changed to accommodate the base station positioning: horizontal, stand or wall mounting.
Setup Figure 10. Arrows showing routing Host Connection: Verify before connection that the reader’s cable type is compatible with your host equipment. Most connections plug directly into the host device as shown below. Keyboard Wedge interface cables have a ‘Y’ connection where its female end mates with the male end of the cable from the keyboard and the remaining end at the keyboard port on the terminal/PC. B Figure 11. Connecting to the Host Wa Ke W or... nd US yb ed oard ge or... M or...
Configuring the Base Station Figure 12. Disconnecting the Cable Insert Paper Clip Connecting the Base when Security Pin is Enabled When connecting the Base to a system that has a custom Security Pin enabled, follow the steps below in the order shown: 1. Power down the host system. 2. Connect the appropriate interface cable into the Base as shown in Figure 11 on page 24. 3. Place the reader in the Base. 4. Power up the host. The reader will link to the Base. 5.
Setup BT Models only Remember: The mandatory condition for establishing a new linking between a BT handheld and a BT base is that the handheld is unlinked and they share the same security configuration. A successful link is indicated by three ascending tones from the reader. A high-low-high-low tone indicates the link attempt was unsuccessful. A single green LED flash after this tone indicates no Base Station was discovered.
GRYPHON™ I System and Network Layouts The link label is a Code 128 function 3 label with the following format: LnkB<12 character bluetooth address> 4. Scan the link label you created in step 3. Linking to a PC in HID 1. Install any drivers provided with the Bluetooth adapter. 2. Scan the Link to a PC in HID barcode below to make the scanner visible to the host computer. Link to a PC in HID 3. Use the host computer's Bluetooth manager to "Discover new devices" and select "Datalogic Scanner.
Setup Figure 14. Multiple Reader Layout Gryphon M4100 only (not valid for BT model) In stand alone systems, each cradle is connected to a single Host. Figure 15. Multiple Stand Alone Layouts Gryphon M4100 only (not valid for BT model) Many stand alone connections can operate in the same physical area without interference, provided all readers and cradles in the system have different addresses.
Interface Selection Interface Selection Upon completing the physical connection between the reader and its host, proceed to Table 1 starting on page 30 to select the interface type the reader is connected to (for example: RS-232, Keyboard Wedge, USB, etc.). Scan the appropriate barcode in that section to configure your system’s correct interface type.
Setup Table 1.
Interface Selection KEYBOARD FEATURES AT, PS/2 25-286, 30-286, 50, 50Z, 60, 70, 80, 90 & 95 w/Standard Key Encoding Select KBD-AT Keyboard Wedge for IBM AT PS2 with standard key encoding but without external keyboard Select KBD-AT-NK AT, PS/2 25-286, 30-286, 50, 50Z, 60, 70, 80, 90 & 95 w/Alternate Key Select KBD-AT-ALT Keyboard Wedge for IBM AT PS2 with alternate key encoding but without external keyboard Set KEYBOARD WEDGE Interface Features starting on page 55 Select KBD-AT-ALT-NK PC/XT w/Stand
Setup KEYBOARD — cont.
Customizing Configuration Settings Customizing Configuration Settings Configure Interface Settings If after scanning the interface barcode from the previous table, your installation requires you to select options to further customize your reader, turn to the appropriate section for your interface type in "Configuration Using Barcodes" starting on page 37.
Setup Resetting the Product Configuration to Defaults Restore Custom Defaults If you aren’t sure what programming options are in your imager, or you’ve changed some options and want to restore the Custom Default Configuration that may have been saved in the scanner, scan the Restore Custom Default Configuration barcode below. This will restore the custom configuration for the currently active interface. Custom defaults are based on the interface type.
Customizing Configuration Settings Replacing the Battery Before replacing the Battery, read "Battery Safety" starting on page 14. Datalogic recommends annual replacement of rechargeable battery packs to ensure maximum performance. To change the battery of your reader, complete the following instructions. 1. With a screwdriver, unscrew the battery cover screw. 2. Unscrew and remove the three screws securing the battery holder, and unplug the white connector. Screw Connector Screw Screw 3.
Setup 4. Remove the old battery from its place (if present), and insert the new battery in the same position. 5. Replace the battery holder and three screws, plug in the connector, and return the contacts circuit to its previous location. When inserting the new battery into the handle, take care to position the battery and the connector as shown. 6. Insert the cover in the handle and screw it back into place. Battery replacement is now complete.
Chapter 3 Configuration Using Barcodes This and following sections provide programming barcodes to configure your reader by changing the default settings. For details about additional methods of programming, see Configuration Methods on page 16. You must first enable your reader to read barcodes in order to use this section. If you have not done this, go to Setup, starting on page 17 and complete the appropriate procedure.
Reading Configuration Barcodes You must first enable your reader to read barcodes in order to use this section. If you have not done this, go to Setup, starting on page 17 and complete the appropriate procedure. To program features: 1. Scan the ENTER/EXIT PROGRAMMING barcode, available at the top of each programming page, when applicable. 2. Scan the barcode to set the desired programming feature.
ENTER/EXIT PROGRAMMING MODE Host Commands — Obey/Ignore GLOBAL INTERFACE FEATURES The following interface features are configurable by all interface types. Host Commands — Obey/Ignore This option specifies whether the reader will obey or ignore host commands. When set to ignore, the reader will ignore all host commands except for those necessary for: • service mode • flash programming mode • keeping the interface active • transmission of labels.
Global Interface Features ENTER/EXIT PROGRAMMING MODE NOTES 40 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300
RS-232 ONLY INTERFACE BAUD RATE on page 42 DATA BITS on page 43 STOP BITS on page 43 PARITY on page 44 HANDSHAKING CONTROL on page 45 Use the programming barcodes in this section if modifications to the standard RS-232 interface settings are necessary to meet your system’s requirements. Additional settings which apply to both the RS-232 and USB interfaces are available in the next section, "RS-232/USB-Com Interfaces" starting on page 46.
ENTER/EXIT PROGRAMMING MODE Baud Rate See page 291 for information on this feature.
ENTER/EXIT PROGRAMMING MODE Data Bits Data Bits This parameter allows the reader to interface with devices requiring a 7-bit or 8-bit ASCII protocol for sending and receiving data. 7 Data Bits DEFAULT 8 Data Bits Stop Bits Set the number of stop bits to match host device requirements. See page 291 for more information on this feature.
ENTER/EXIT PROGRAMMING MODE Parity This feature specifies parity required for sending and receiving data. Select the parity type according to host device requirements. See page 291 for more information.
ENTER/EXIT PROGRAMMING MODE Handshaking Control Handshaking Control See page 291 for more information about this feature.
RS-232/USB-COM INTERFACES INTERCHARACTER DELAY on page 47 BEEP ON ASCII BEL on page 47 BEEP ON NOT ON FILE on page 48 ACK NAK OPTIONS on page 49 ACK CHARACTER on page 50 NAK CHARACTER on page 50 ACK NAK TIMEOUT VALUE on page 51 ACK NAK RETRY COUNT on page 51 ACK NAK ERROR HANDLING on page 52 INDICATE TRANSMISSION FAILURE on page 52 DISABLE CHARACTER on page 53 ENABLE CHARACTER on page 53 The programming barcodes in this chapter allow modifications to the standard RS-232 and USB-Com interfaces.
ENTER/EXIT PROGRAMMING MODE Intercharacter Delay Intercharacter Delay This parameter specifies the intercharacter delay between the end of one character and the beginning of the next. The delay can be set within a range of zero (0) to 990 milliseconds in 10ms increments. A setting of zero specifies no delay. See page 292 for more information. Intercharacter Delay = No Delay Select Intercharacter Delay Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string.
ENTER/EXIT PROGRAMMING MODE Beep On Not on File This option enables/disables the action of the reader to sound a three beep sequence upon receiving a Not-On-File (NOF) host command.
ENTER/EXIT PROGRAMMING MODE ACK NAK Options ACK NAK Options This enables/disables the ability of the reader to support the RS-232 ACK/NAK protocol. See page 293 for more information.
ENTER/EXIT PROGRAMMING MODE ACK Character This setting specifies an ASCII character or hex value to be used as the ACK character. ASCII characters or any hex value from 0 to 0xFF can be selected. See page 293 for more information. Setting to previously defined characters such as XON, XOFF, or host commands conflicts with normal operation of these characters. 8-bit data is not recognized when the option Data Bits has been set as 7 Data Bits.
ENTER/EXIT PROGRAMMING MODE ACK NAK Timeout Value ACK NAK Timeout Value This option specifies the amount of time the reader waits for an ACK character from the host following label transmission. The selectable timeout range is 200 milliseconds to 15,000ms (15 seconds) in 200ms increments. A selection of 0 disables the timeout. See page 295 for more information on setting this feature. Select ACK NAK Timeout Value Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string.
ENTER/EXIT PROGRAMMING MODE ACK NAK Error Handling This feature specifies the method the reader uses to handle receive errors detected while waiting for an ACK character from the host.
ENTER/EXIT PROGRAMMING MODE Disable Character Disable Character Specifies the value of the RS-232 host command used to disable the reader. ASCII characters or any hex value from 0 to 0xFF can be selected. Setting to previously defined characters such as XON, XOFF, or host commands conflicts with normal operation of these characters. 8bit data is not recognized when the option Data Bits has been set as 7 Data Bits. See page 297 for more information on setting this feature.
ENTER/EXIT PROGRAMMING MODE NOTES 54 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300
KEYBOARD INTERFACE COUNTRY MODE on page 56 CAPS LOCK STATE on page 59 NUMLOCK on page 60 SEND CONTROL CHARACTERS on page 61 WEDGE QUIET INTERVAL on page 62 INTERCHARACTER DELAY on page 63 INTERCODE DELAY on page 64 USB KEYBOARD SPEED on page 65 USB KEYBOARD NUMERIC KEYPAD on page 66 Use the programming barcodes in this chapter to select options for USB Keyboard and Wedge Interfaces. Reference Appendix B, Standard Defaults for a listing of standard factory settings.
ENTER/EXIT PROGRAMMING MODE Country Mode This feature specifies the country/language supported by the keyboard. Only the following interfaces support ALL Country Modes.
ENTER/EXIT PROGRAMMING MODE Country Mode Country Mode — continued Supports only the interfaces listed in the Country Mode feature description. Country Mode = Denmark Country Mode = France Country Mode = French Canadian Country Mode = Germany Supports only the interfaces listed in the Country Mode feature description. Country Mode = Hungary Country Mode = Italy Supports only the interfaces listed in the Country Mode feature description.
ENTER/EXIT PROGRAMMING MODE Country Mode — continued Country Mode = Lithuanian Supports only the interfaces listed in the Country Mode feature description. Country Mode = Norway Supports only the interfaces listed in the Country Mode feature description. Country Mode = Poland Supports only the interfaces listed in the Country Mode feature description. Country Mode = Portugal Supports only the interfaces listed in the Country Mode feature description.
ENTER/EXIT PROGRAMMING MODE Caps Lock State Country Mode — continued Country Mode = Sweden Supports only the interfaces listed in the Country Mode feature description. Country Mode = Switzerland Caps Lock State This option specifies the format in which the reader sends character data. This applies to keyboard wedge interfaces and Bluetooth HID Profile. This does not apply when an alternate key encoding keyboard is selected.
ENTER/EXIT PROGRAMMING MODE Numlock This option specifies the setting of the Numbers Lock (Numlock) key while in keyboard wedge interface. This only applies to alternate key encoding interfaces. It does not apply to USB keyboard.
ENTER/EXIT PROGRAMMING MODE Send Control Characters Send Control Characters This feature Specifies how the reader transmits ASCII control characters to the host. Reference Appendix E, Scancode Tables for more information about control characters. Options are as follows: Control Character 00 . Characters from 00 to 0x1F are sent as control character Ctrl+Keys, special keys are located from 0x80 to 0xA1. Control Character 01 .
ENTER/EXIT PROGRAMMING MODE Wedge Quiet Interval This option specifies the amount of time to look for keyboard activity before the reader breaks the keyboard connection in order to transmit data to host. The selectable range for this feature is from 0 to 990ms in 10ms increments. This feature applies ONLY to the Keyboard Wedge interface. See page 299 in “References” for detailed information and examples for setting this feature.
ENTER/EXIT PROGRAMMING MODE Intercharacter Delay Intercharacter Delay This parameter specifies the intercharacter delay between the end of one character and the beginning of the next. The delay can be set within a range of zero (0) to 990 milliseconds in 10ms increments. A setting of zero specifies no delay. This feature applies ONLY to the Keyboard Wedge interface and Bluetooth HID Profile. See page 300 in “References” for detailed information and examples for setting this feature.
ENTER/EXIT PROGRAMMING MODE Intercode Delay Specifies the delay between labels transmitted to the host for this interface. The selectable range for this feature is from 0 to 99 seconds. See page 301 in “References” for detailed information and examples for setting this feature. Set Intercode Delay Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning.
ENTER/EXIT PROGRAMMING MODE USB Keyboard Speed USB Keyboard Speed This option specifies the USB poll rate for a USB keyboard. This feature applies ONLY to the USB Keyboard interface.
ENTER/EXIT PROGRAMMING MODE USB Keyboard Speed — continued USB Keyboard Speed = 7ms USB Keyboard Speed = 8ms USB Keyboard Speed = 9ms USB Keyboard Speed = 10ms USB Keyboard Numeric Keypad This option Controls whether numeric characters will be sent using standard keys or the numeric keypad.
USB-OEM INTERFACE USB-OEM DEVICE USAGE on page 68 INTERFACE OPTIONS on page 68 Feature settings for USB interfaces differ depending upon which host type the reader will be connected with. Use the feature settings in this chapter and "IBM 46XX Interface"on page 69 to specifically configure for the USB-OEM interface. Other USB interfaces are included in the appropriate chapter for their host type. Reference Appendix B, Standard Defaults for a listing of standard factory settings.
ENTER/EXIT PROGRAMMING MODE USB-OEM Device Usage The USB-OEM protocol allows for the reader to be identified as one of two different types of barcode scanners. Depending on what other scanners you may already have connected to a USB-OEM POS, you may need to change this setting to enable all devices to communicate. Options are: • Table Top Scanner • Handheld Scanner It may be necessary to switch device usage when connecting two readers/scanners of the same type to a POS system.
IBM 46XX INTERFACE 46XX NUMBER OF HOST RESETS on page 70 TRANSMIT LABELS IN CODE 39 FORMAT on page 72 INTERFACE OPTIONS on page 72 Use the barcodes in this section to configure programmable features for available IBM 46XX interfaces. Reference Appendix B, Standard Defaults for a listing of standard factory settings.
ENTER/EXIT PROGRAMMING MODE 46xx Number of Host Resets Specifies how many consecutive resets are processed before the reader starts a five-second period to allow the user to enter Programming Mode and configure the reader. The configurable range for this feature is 1 to 15 resets.
ENTER/EXIT PROGRAMMING MODE 46xx Number of Host Resets 46xx Number of Host Resets — cont.
ENTER/EXIT PROGRAMMING MODE Transmit Labels in Code 39 Format This feature enable/disables translation to Code 39 before transmitting label data to an IBM46XX or a USB-OEM host. Only the symbology identifier is modified for the translation. The data is not converted to Code 39 or verified to be valid for Code 39. Options are: IBM Standard Format. Send labels in standard IBM format. Code 39 Format.
WAND EMULATION INTERFACE WAND SIGNAL SPEED on page 74 WAND POLARITY on page 74 WAND IDLE STATE on page 75 TRANSMIT NOISE on page 75 LABEL SYMBOLOGY CONVERSION on page 76 This chapter provides feature/settings configuration for the Wand Emulation interface. Reference Appendix B, Standard Defaults for a listing of standard factory settings.
ENTER/EXIT PROGRAMMING MODE Wand Signal Speed This feature specifies the speed of the Wand output signal per nominal bar or space. Choices are: • 330 microseconds • 660 microseconds Wand Signal Speed = 330ms DEFAULT Wand Signal Speed = 660ms Wand Polarity This option specifies the polarity of the Wand output signal. Choices are: • Quiet zones and spaces are high, bars are low • Quiet zones and spaces are low, bars are high TTL logic levels: 0V <= Low <= 0.7V 2.4V <= High <= 5.
ENTER/EXIT PROGRAMMING MODE Wand Idle State Wand Idle State This feature specifies the level of the Wand output signal when the reader is idle. TTL logic levels: 0V <= Low <= 0.7V 2.4V <= High <= 5.25V Wand Idle State = Low DEFAULT Wand Idle State = High Transmit Noise This option specifies the leading/trailing noise for the Wand interface.
ENTER/EXIT PROGRAMMING MODE Label Symbology Conversion When this feature is enabled for the Wand Emulation interface, all barcode labels are converted to a single symbology.
DATA FORMAT GLOBAL PREFIX/SUFFIX on page 78 GLOBAL AIM ID on page 79 GS1-128 AIM ID on page 80 LABEL ID starting on page 81 • • • • • Label ID: Pre-loaded Sets Label ID: Set Individually Per Symbology Label ID Control Label ID Symbology Selection Set Global Mid Label ID Characters CASE CONVERSION on page 90 CHARACTER CONVERSION on page 90 It is not recommended to use these features with IBM interfaces.
ENTER/EXIT PROGRAMMING MODE Global Prefix/Suffix This option sets up to 20 characters each from the set of ASCII characters or any hex value from 00 to FF. The characters may be added as a prefix (in a position before the barcode data, also called a header) and/or as a suffix (in a position following the barcode data, also called a footer). See page 305 for more detailed instructions on setting this feature.
ENTER/EXIT PROGRAMMING MODE Global AIM ID Global AIM ID This feature enables/disables addition of AIM IDs for all symbology types. AIM label identifiers (as opposed to custom characters you select yourself as with label identifiers) can be included with scanned barcode data. AIM label identifiers consist of three characters as follows: • A close brace character (ASCII ‘]’), followed by... • A code character (see the table below), followed by...
ENTER/EXIT PROGRAMMING MODE GS1-128 AIM ID If Global AIM ID is disabled, the AIM ID for GS1-128 can be enabled/disabled independently. The AIM ID for GS1-128 is a ]C1, ]C2 or ]C3. AIM IDs for other symbologies can be enabled/disabled independently as well.
ENTER/EXIT PROGRAMMING MODE Label ID Label ID A Label ID is a customizable code of up to three ASCII characters (each can be one of hex 0x010xFF), used to identify a barcode (symbology) type. It can be appended previous to or following the transmitted barcode data depending upon how this option is enabled.
ENTER/EXIT PROGRAMMING MODE Label ID Control This option controls whether a Label ID is disabled, or sent as a prefix or suffix for a given symbology type. DEFAULT Label ID Transmission = Disable Label ID Transmission = Enable as Prefix Label ID Transmission = Enable as Suffix Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning.
ENTER/EXIT PROGRAMMING MODE Label ID Symbology Selection Label ID Symbology Selection This option selects the symbology for which a Label ID is to be configured. See "Label ID" on page 81 or page 309 in “References” for more detailed instructions.
ENTER/EXIT PROGRAMMING MODE Label ID Symbology Selection — continued Set UPC-E/GS1-128 Label ID Character(s) Set EAN 13 Label ID Character(s) Set EAN 13/P2 Label ID Character(s) Set EAN 13/P5 Label ID Character(s) Set EAN 13/GS1-128 Label ID Character(s) Set EAN 8 Label ID Character(s) Set EAN 8/P2 Label ID Character(s) 84 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300
ENTER/EXIT PROGRAMMING MODE Label ID Symbology Selection Label ID Symbology Selection — continued Set EAN 8/P5 Label ID Character(s) Set EAN 8/GS1-128 Label ID Character(s) Set GTIN Label ID Character(s) Set GTIN/P2 Label ID Character(s) Set GTIN/P5 Label ID Character(s) Set GTIN/GS1-128 Label ID Character(s) Set Code 39 Label ID Character(s) Product Reference Guide 85
ENTER/EXIT PROGRAMMING MODE Label ID Symbology Selection — continued Set Code 32 Label ID Character(s) Set Code 39 CIP Label ID Character(s) Set Code 128 Label ID Character(s) Set GS1-128 Label ID Character(s) Set ISBT 128 Label ID Character(s) Set Codablock F Label ID Character(s) Set Interleaved 2 of 5 Label ID Character(s) Set Follett 2 of 5 Label ID Character(s) 86 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300
ENTER/EXIT PROGRAMMING MODE Label ID Symbology Selection Label ID Symbology Selection — continued Set Interleaved 2 of 5 CIP HR Label ID Character(s) Set Standard 2 of 5 Label ID Character(s) Set Industrial 2 of 5 Label ID Character(s) Set IATA Label ID Character(s) Set Datalogic 2 of 5 Label ID Character(s) Set Codabar Label ID Character(s) Set ABC Codabar Label ID Character(s) Product Reference Guide 87
ENTER/EXIT PROGRAMMING MODE Label ID Symbology Selection — continued Set Code 11 Label ID Character(s) Set DataBar Omnidirectional Label ID Character(s) Set DataBar Expanded Label ID Character(s) Set DataBar Limited Label ID Character(s) Set Code 93 Label ID Character(s) Set MSI Label ID Character(s) Set Plessey Label ID Character(s) 88 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300
ENTER/EXIT PROGRAMMING MODE Set Global Mid Label ID Characters Label ID Symbology Selection — continued Set Anker Plessey Label ID Character(s) Set Code 4 Label ID Character(s) Set Code 5 Label ID Character(s) Set Global Mid Label ID Characters Specifies mid-label ID that is added for transmission between the labels of a two-label pair.
ENTER/EXIT PROGRAMMING MODE Case Conversion This feature allows conversion of the case of all alphabetic characters to upper or lower case. Case conversion affects ONLY scanned barcode data, and does not affect Label ID, Prefix, Suffix, or other appended data. DEFAULT Case Conversion = Disable (no case conversion) Case Conversion = Convert to upper case Case Conversion = Convert to lower case Character Conversion Character conversion is an eight byte configuration item.
READING PARAMETERS DOUBLE READ TIMEOUT on page 92 GOOD READ LED DURATION on page 100 LABEL GONE TIMEOUT on page 93 SCAN MODE on page 101 SLEEP MODE TIMEOUT on page 94 STAND MODE TRIGGERED TIMEOUT on page 102 POWER ON ALERT on page 96 STAND DETECTION on page 103 GOOD READ: WHEN TO INDICATE on page 96 STAND MODE SENSITIVITY on page 104 GOOD READ BEEP TYPE on page 97 SCANNING ACTIVE TIME on page 104 GOOD READ BEEP FREQUENCY on page 97 FLASH ON TIME on page 105 GOOD READ BEEP LENGTH on page 98 FLA
ENTER/EXIT PROGRAMMING MODE Double Read Timeout Double Read Timeout prevents a double read of the same label by setting the minimum time allowed between reads of labels of the same symbology and data. If the unit reads a label and sees the same label again within the specified timeout, the second read is ignored. Double Read Timeout does not apply to scan modes that require a trigger pull for each label read. Double Read Timeout = 0.1 Second Double Read Timeout = 0.2 Second Double Read Timeout = 0.
ENTER/EXIT PROGRAMMING MODE Label Gone Timeout Double Read Timeout — continued Double Read Timeout = 0.8 Second Double Read Timeout = 0.9 Second Double Read Timeout = 1 Second Label Gone Timeout This feature sets the time after the last label segment is seen before the reader prepares for a new label. The timeout can be set within a range of 10 milliseconds to 2,550 milliseconds (2.55 seconds) in 10ms increments.
ENTER/EXIT PROGRAMMING MODE Sleep Mode Timeout This feature sets the amount of time that the reader will be idle before it enters into a low power Sleep Mode. When in Sleep Mode the reader can no longer receive commands from the Host or base station until it is woken up again by a trigger pull or being placed into a base station. In order for the reader to enter Sleep Mode, the following conditions must be met: Corded version (GD4100 only).
ENTER/EXIT PROGRAMMING MODE Sleep Mode Timeout Sleep Mode Timeout — continued Sleep Mode Timeout = 5 Seconds Sleep Mode$ Timeout = 6 Seconds $ Timeout = 7 Seconds Sleep Mode Sleep Mode Timeout = 8 Seconds Sleep Mode Timeout = 9 Seconds Sleep Mode Timeout = 10 Seconds Product Reference Guide 95
LED and Beeper Indicators ENTER/EXIT PROGRAMMING MODE LED AND BEEPER INDICATORS Power On Alert Disables or enables the indication (from the Beeper) that the reader is receiving power. Power On Alert = Disable (No Audible Indication) DEFAULT Power On Alert = Four Beeps Good Read: When to Indicate This feature specifies when the reader will provide indication (beep and/or flash its green LED) upon successfully reading a barcode. . This option, which uses CTS, is only valid for RS-232 interfaces.
ENTER/EXIT PROGRAMMING MODE Good Read Beep Type Good Read Beep Type Specifies whether the good read beep has a mono or bitonal beep sound. DEFAULT Good Read Beep Type = Mono Good Read Beep Type = Bitonal Good Read Beep Frequency Adjusts the good read beep to sound at a selectable low, medium or high frequency, selectable from the list below. (Controls the beeper’s pitch/tone.
LED and Beeper Indicators ENTER/EXIT PROGRAMMING MODE Good Read Beep Length Good Read Beep Length = 60 msec DEFAULT Good Read Beep Length = 80 msec Good Read Beep Length = 100 msec Good Read Beep Length = 120 msec Good Read Beep Length = 140 msec Good Read Beep Length = 160 msec Good Read Beep Length = 180 msec Good Read Beep Length = 200 msec 98 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300
ENTER/EXIT PROGRAMMING MODE Good Read Beep Volume Good Read Beep Volume Selects the beeper volume (loudness) upon a good read beep. There are three selectable volume levels.
LED and Beeper Indicators ENTER/EXIT PROGRAMMING MODE Good Read LED Duration This feature specifies the amount of time that the Good Read LED remains on following a good read. The good read LED on time can be set within a range of 10 milliseconds to 2,550 milliseconds (0.001 to 2.55 seconds) in 100ms increments. See page 313 in “References” for detailed instructions and examples for setting this feature.
ENTER/EXIT PROGRAMMING MODE Scan Mode SCANNING FEATURES Scan Mode Selects the reader’s scan operating mode. See page 314 in “References” for descriptions. DEFAULT Scan Mode = Trigger Single Scan Mode = Trigger Hold Multiple Scan Mode = Trigger Pulse Multiple Scan Mode = Flashinga Scan Mode = Always Onb Scan Mode = Stand Modec Scan Mode = Trigger Object Sense c a. Recommended scan mode for Gryphon L for hands-free stand mode operation. b.
Scanning Features ENTER/EXIT PROGRAMMING MODE Stand Mode Triggered Timeout This feature specifies the time to remain in Trigger Single mode after the trigger is pulled while in Stand Mode. This timeout is only used when the Scan Mode is configured as Stand Mode. This feature is not applicable to the Gryphon L model. DEFAULT Stand Mode Triggered Timeout = 0.5 Seconds Stand Mode Triggered Timeout = 1.
ENTER/EXIT PROGRAMMING MODE Stand Detection Stand Mode Triggered Timeout — continued Stand Mode Triggered Timeout = 8 Seconds Stand Mode Triggered Timeout = Switch back to Trigger Single on trigger pull Stand Detection Specifies the behavior of the scanner when placed in a stand that contains autorecognition hardware. This feature is not applicable to the Gryphon L.
Scanning Features ENTER/EXIT PROGRAMMING MODE Stand Mode Sensitivity Sets the sensitivity level for stand mode wakeup. Choices are low, medium and high. This feature is not applicable to the Gryphon L. Stand Mode Sensitivity = Low DEFAULT Stand Mode Sensitivity = Medium Stand Mode Sensitivity = High Scanning Active Time This setting specifies the amount of time that the reader stays in scan ON state once the state is entered. The range for this setting is from 1 to 255 seconds in 1-second increments.
ENTER/EXIT PROGRAMMING MODE Flash On Time Flash On Time This feature specifies the ON time for the indicator LED while in Flash Mode. The selectable range is 100 to 9,900 milliseconds (0.1 to 9.9 seconds), in 100 millisecond increments.See page 316 in “References” for detailed information on setting this feature. Select Flash ON Time Setting Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning.
Scanning Features ENTER/EXIT PROGRAMMING MODE Green Spot Duration Specifies the duration of the good read pointer beam after a good read.
CODE SELECTION The reader supports the following symbologies (barcode types). Symbology-dependent options for each symbology are included in this chapter.
Disable All Symbologies 3. If additional input parameters are needed, go to Appendix D, Keypad, and scan the appropriate characters from the keypad. Additional information about many features can be found in the “References” chapter. If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. 4. Complete the programming sequence by scanning the ENTER/EXIT PROGRAMMING barcode to exit Programming Mode.
ENTER/EXIT PROGRAMMING MODE Coupon Control CODE EAN/UPC Coupon Control This feature is used to control the reader’s method of processing coupon labels.
Code EAN/UPC ENTER/EXIT PROGRAMMING MODE UPC-A The following options apply to the UPC-A symbology. UPC-A Enable/Disable When disabled, the reader will not read UPC-A barcodes. UPC-A = Disable DEFAULT UPC-A = Enable UPC-A Check Character Transmission Enable this option to transmit the check character along with UPC-A barcode data.
ENTER/EXIT PROGRAMMING MODE Expand UPC-A to EAN-13 Expand UPC-A to EAN-13 Expands UPC-A data to the EAN-13 data format. Selecting this feature also changes the symbology ID to match those required for EAN-13. DEFAULT UPC-A to EAN-13 = Don’t Expand UPC-A to EAN-13 = Expand UPC-A Number System Character Transmission This feature enables/disables transmission of the UPC-A number system character.
Code EAN/UPC ENTER/EXIT PROGRAMMING MODE UPC-A Minimum Reads This feature specifies the minimum number of consecutive times a UPC-A label must be decoded before it is accepted as a good read.
ENTER/EXIT PROGRAMMING MODE UPC-E Enable/Disable UPC-E The following options apply to the UPC-E symbology. UPC-E Enable/Disable When disabled, the reader will not read UPC-E barcodes. UPC-E = Disable DEFAULT UPC-E = Enable UPC-E Check Character Transmission Enable this option to transmit the check character along with UPC-E barcode data.
UPC-E ENTER/EXIT PROGRAMMING MODE Expand UPC-E to EAN-13 Expands UPC-E data to the EAN-13 data format. Selecting this feature also changes the symbology ID to match those required for EAN-13. DEFAULT UPC-E to EAN-13 = Don’t Expand UPC-E to EAN-13 = Expand Expand UPC-E to UPC-A Expands UPC-E data to the UPC-A data format.
ENTER/EXIT PROGRAMMING MODE UPC-E Number System Character Transmission UPC-E Number System Character Transmission This feature enables/disables transmission of the UPC-E system number character. UPC-E Number System Character = Do not transmit DEFAULT UPC-E Number System Character = Transmit UPC-E Minimum Reads Specifies the minimum number of consecutive times a UPC-E label must be decoded before it is accepted as a good read.
GTIN Formatting ENTER/EXIT PROGRAMMING MODE GTIN FORMATTING This feature enables/disables the ability to convert UPC-E, UPC-A, EAN 8, and EAN 13 labels into the GTIN 14-character format. If add-on information is present on the base label prior to the conversion taking place, the add-on information will be appended to the converted GTIN label.
ENTER/EXIT PROGRAMMING MODE EAN 13 Enable/Disable EAN 13 (JAN 13) The following options apply to the EAN 13 (Jan 13) symbology. EAN 13 Enable/Disable When disabled, the reader will not read EAN 13/JAN 13 barcodes. EAN 13 = Disable DEFAULT EAN 13 = Enable EAN 13 Check Character Transmission Enable this option to transmit the check character along with EAN 13 barcode data.
EAN 13 (Jan 13) ENTER/EXIT PROGRAMMING MODE EAN-13 Flag 1 Character Enables/disables transmission of an EAN/JAN13 Flag1 character. The Flag 1 character is the first character of the label. EAN-13 Flag 1 Char= Don’t transmit DEFAULT EAN-13 Flag 1 Char= Transmit EAN-13 ISBN Conversion This option enables/disables conversion of EAN 13/JAN 13 Bookland labels starting with 978 to ISBN labels.
ENTER/EXIT PROGRAMMING MODE EAN 13 Minimum Reads EAN 13 Minimum Reads This feature specifies the minimum number of consecutive times an EAN 13 label must be decoded before it is accepted as good read.
ISSN ENTER/EXIT PROGRAMMING MODE ISSN The following options apply to the ISSN symbology. ISSN Enable/Disable Enables/disables conversion of EAN/JAN13 Bookland labels starting with 977 to ISSN labels.
ENTER/EXIT PROGRAMMING MODE EAN 8 Enable/Disable EAN 8 (JAN 8) The following options apply to the EAN 8 (Jan 8) symbology. EAN 8 Enable/Disable When disabled, the reader will not read EAN 8/JAN 8 barcodes. EAN 8 = Disable DEFAULT EAN 8 = Enable EAN 8 Check Character Transmission Enable this option to transmit the check character along with EAN 8 barcode data.
EAN 8 (Jan 8) ENTER/EXIT PROGRAMMING MODE Expand EAN 8 to EAN 13 Enable this option to expand EAN 8/JAN 8 labels to EAN 13/JAN 13. DEFAULT Expand EAN 8 to EAN 13 = Disable Expand EAN 8 to EAN 13 = Enable EAN 8 Minimum Reads This feature specifies the minimum number of consecutive times an EAN 8 (Jan 8) label must be decoded before it is accepted as good read.
ENTER/EXIT PROGRAMMING MODE UPC/EAN Decoding Level UPC/EAN GLOBAL SETTINGS This section provides configuration settings for UPC-A, UPC-E, EAN 13 and EAN 8 symbologies, and affects all of these unless otherwise marked for each feature description. UPC/EAN Decoding Level Decoding Levels are used to configure a barcode symbology decoder to be very aggressive to very conservative depending on a particular customer’s needs. See page 302 for more information on this feature.
UPC/EAN Global Settings ENTER/EXIT PROGRAMMING MODE UPC/EAN Correlation When correlation is enabled, the reader will combine label data from multiple scans when decoding. This will help the scanner read labels that have spots, voids and/or damaged areas. Enabling correlation will also increase the chances that a label will be read incorrectly.
ENTER/EXIT PROGRAMMING MODE In-Store Minimum Reads In-Store Minimum Reads This feature specifies the minimum number of consecutive times an in-store label must be decoded before it is accepted as good read. In-store labels are defined as UPC-A labels with a number-system character of 2 or 4 as well as EAN 8 and EAN 13 labels with a Flag1 character of 2 or an EAN 13 label starting with the three characters '980'.
Add-Ons ENTER/EXIT PROGRAMMING MODE ADD-ONS Contact Customer Support for advanced programming of optional and conditional add-ons. Optional Add-ons The reader can be enabled to optionally read the following add-ons (supplementals): If a UPC/EAN base label and an add-on are both decoded, the reader will transmit the base label and add-on. If a UPC/EAN base label is decoded without an add-on, the base label will be transmitted without an add-on.
ENTER/EXIT PROGRAMMING MODE Optional Add-On Timer Optional Add-On Timer This option sets the time the reader will look for an add-on when an add-on fragment has been seen and optional add-ons are enabled. (Also see "Optional GS1-128 Add-On Timer" on page 130.
Add-Ons ENTER/EXIT PROGRAMMING MODE Optional Add-On Timer — cont.
ENTER/EXIT PROGRAMMING MODE Optional Add-On Timer Optional Add-On Timer — cont.
Add-Ons ENTER/EXIT PROGRAMMING MODE Optional GS1-128 Add-On Timer This option sets the timer expiration value to read the added part after reading the linear EAN/ UPC part. For UPC/EAN add-ons other than those of that type, see "Optional Add-On Timer" on page 127.
ENTER/EXIT PROGRAMMING MODE Optional GS1-128 Add-On Timer Optional GS1-128 Add-On Timer — cont.
Add-Ons ENTER/EXIT PROGRAMMING MODE Optional GS1-128 Add-On Timer — cont.
ENTER/EXIT PROGRAMMING MODE P2 Add-Ons Minimum Reads P2 Add-Ons Minimum Reads This feature specifies the minimum number of times a P2 add-on must be read before it is marked as valid and then combined with a base label.
Add-Ons ENTER/EXIT PROGRAMMING MODE P5 Add-Ons Minimum Reads This feature specifies the minimum number of times a P5 add-on must be read before it is marked as valid and then combined with a base label.
ENTER/EXIT PROGRAMMING MODE GS1-128 Add-Ons Minimum Reads GS1-128 Add-Ons Minimum Reads This feature specifies the minimum number of times an GS1-128 add-on must be read before it is marked as valid and then combined with a base label.
Code 39 ENTER/EXIT PROGRAMMING MODE CODE 39 The following options apply to the Code 39 symbology. Code 39 Enable/Disable Code 39 = Disable DEFAULT Code 39 = Enable Code 39 Check Character Calculation Enable this option to enables/disables calculation and verification of an optional Code 39 check character.
ENTER/EXIT PROGRAMMING MODE Code 39 Check Character Transmission Code 39 Check Character Calculation — cont. Code 39 Check Character Calculation = Enable Italian Post Check Code 39 Check Character Calculation = Enable Daimler Chrysler Check Code 39 Check Character Transmission Enable this option to transmit the check character along with Code 39 barcode data.
Code 39 ENTER/EXIT PROGRAMMING MODE Code 39 Start/Stop Character Transmission Enable this option to enable/disable transmission of Code 39 start and stop characters. DEFAULT Code 39 Start/Stop Character Transmission = Don’t Transmit Code 39 Start/Stop Character Transmission = Transmit Code 39 Full ASCII Enables/disables the translation of Code 39 characters to Code 39 full-ASCII characters.
ENTER/EXIT PROGRAMMING MODE Code 39 Quiet Zones Code 39 Quiet Zones This feature specifies the number of quiet zones for Code 39 labels. Quiet zones are blank areas at the ends of a barcode, typically 10 times the width of the narrowest bar or space in the label.
Code 39 ENTER/EXIT PROGRAMMING MODE Code 39 Minimum Reads This feature specifies the minimum number of consecutive times a Code 39 label must be decoded before it is accepted as good read.
ENTER/EXIT PROGRAMMING MODE Code 39 Decoding Level Code 39 Decoding Level Decoding Levels are used to configure a barcode symbology decoder to be very aggressive to very conservative depending on a particular customer’s needs. See page 302 for more information on this feature. This configuration item applies to Code 39 and Code 32.
Code 39 ENTER/EXIT PROGRAMMING MODE Code 39 Length Control This feature specifies either variable length decoding or fixed length decoding for the Code 39 symbology. Variable Length. For variable length decoding, a minimum and maximum length may be set. Fixed Length. For fixed length decoding, two different lengths may be set.
ENTER/EXIT PROGRAMMING MODE Code 39 Set Length 1 Code 39 Set Length 1 This feature specifies one of the barcode lengths for Code 39 Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the barcode’s data characters only. The length can be set from 0 to 50 characters. Table 2 provides examples for setting Length 1. See page 302 for detailed instructions on setting this feature. Table 2.
Code 39 ENTER/EXIT PROGRAMMING MODE Code 39 Set Length 2 This feature specifies one of the barcode lengths for Code 39 Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Length includes the barcode’s check, data, and full-ASCII shift characters. The length does not include start/stop characters. Table 3 provides examples for setting Length 2. See page 303 for detailed instructions on setting this feature. Table 3.
ENTER/EXIT PROGRAMMING MODE Code 39 Interdigit Ratio Code 39 Interdigit Ratio This feature specifies the ratio between an intercharacter space and module for Code 39 labels.
Code 39 ENTER/EXIT PROGRAMMING MODE Code 39 Interdigit Ratio — cont.
ENTER/EXIT PROGRAMMING MODE Code 39 Character Correlation Code 39 Character Correlation When correlation is enabled, the barcode reader will combine label data from multiple scans when decoding. Enabling correlation will help the scanner read labels that have some spots and/ or voids. It may also help read labels that have damaged areas. Enabling correlation will also increase the chances that a label will be read incorrectly.
Code 32 (ITAL Pharmaceutical Code) ENTER/EXIT PROGRAMMING MODE CODE 32 (ITAL PHARMACEUTICAL CODE) The following options apply to the Code 32 (Italian Pharmaceutical Code) symbology. Code 32 Enable/Disable When disabled, the reader will not read Code 32 barcodes.
ENTER/EXIT PROGRAMMING MODE Code 32 Check Char Transmission Code 32 Check Char Transmission Enable this option to transmit the check character along with Code 32 barcode data. DEFAULT Code 32 Check Character Transmission = Don’t Send Code 32 Check Character Transmission = Send Code 32 Start/Stop Character Transmission This option enables/disables transmission of Code 32 start and stop characters.
Code 39 CIP (French Pharmaceutical) ENTER/EXIT PROGRAMMING MODE CODE 39 CIP (FRENCH PHARMACEUTICAL) The following options apply to the Code 39 CIP symbology. Code 39 CIP Enable/Disable Enables/Disables ability of the reader to decode Code 39 CIP labels.
ENTER/EXIT PROGRAMMING MODE Code 128 Enable/Disable CODE 128 The following options apply to the Code 128 symbology. Code 128 Enable/Disable When disabled, the reader will not read Code 128 barcodes. Code 128 = Disable DEFAULT Code 128 = Enable Expand Code 128 to Code 39 This feature enables/disables expansion of Code 128 labels to Code 39 labels.
Code 128 ENTER/EXIT PROGRAMMING MODE Code 128 Check Character Transmission Enable this option to transmit the check character along with Code 128 barcode data. DEFAULT Code 128 Check Character Transmission = Don’t Send Code 128 Check Character Transmission = Send Code 128 Function Character Transmission Enables/disables transmission of Code128 function characters 1, 2, 3, and 4.
ENTER/EXIT PROGRAMMING MODE Code 128 Sub-Code Change Transmission Code 128 Sub-Code Change Transmission Enables/disables the transmission of “Sub-Code exchange” characters (NOT transmitted by standard decoding).
Code 128 ENTER/EXIT PROGRAMMING MODE Code 128 Quiet Zones This feature specifies the number of quiet zones for Code 128 labels. Quiet zones are blank areas at the ends of a barcode and are typically 10 times the width of the narrowest bar or space in the label.
ENTER/EXIT PROGRAMMING MODE Code 128 Minimum Reads Code 128 Minimum Reads This feature specifies the minimum number of consecutive times a Code 128 label must be decoded before it is accepted as good read.
Code 128 ENTER/EXIT PROGRAMMING MODE Code 128 Decoding Level Decoding Levels are used to configure a barcode symbology decoder to be very aggressive to very conservative depending on a particular customer’s needs. See page 302 for more information on this feature.
ENTER/EXIT PROGRAMMING MODE Code 128 Length Control Code 128 Length Control This feature specifies either variable length decoding or fixed length decoding for the Code 128 symbology. See page 302 for more information..
Code 128 ENTER/EXIT PROGRAMMING MODE Code 128 Set Length 1 Specifies one of the barcode lengths for Code 128 Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the barcode’s data characters only. The length can be set from 1 to 80 characters. Table 4 provides some examples for setting Length 1. See page 302 for detailed instructions on setting this feature. Table 4.
ENTER/EXIT PROGRAMMING MODE Code 128 Set Length 2 Code 128 Set Length 2 This feature specifies one of the barcode lengths for Code 128 Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Length includes the barcode’s data characters only. The length can be set from 1 to 80 characters. A setting of 0 specifies to ignore this length (only one fixed length). Table 5 provides examples for setting Length 2.
Code 128 ENTER/EXIT PROGRAMMING MODE Code 128 Character Correlation When correlation is enabled, the barcode reader will combine label data from multiple scans when decoding. Enabling correlation will help the scanner read labels that have some spots and/ or voids. It may also help read labels that have damaged areas. Enabling correlation will also increase the chances that a label will be read incorrectly.
ENTER/EXIT PROGRAMMING MODE GS1-128 Enable GS1-128 The following options apply to the GS1-128 symbology. (Also known as USS-128, GS1-128, GTIN-128, UCC-128, EAN-128.) GS1-128 Enable This option enables/disables the ability of the reader to translate GS1-128 labels to the GS1-128 data format. Options are: • Transmit GS1-128 labels in Code 128 data format. • Transmit GS1-128 labels in GS1-128 data format. • Do not transmit GS1-128 labels.
Code ISBT 128 ENTER/EXIT PROGRAMMING MODE CODE ISBT 128 The following options apply to the ISBT 128 symbology. ISBT 128 Concatenation Use this option to enable/disable ISBT128 concatenation of 2 labels. DEFAULT ISBN 128 Concatenation = Disable ISBN 128 Concatenation = Enable ISBT 128 Force Concatenation When enabled, this feature forces concatenation for ISBT. This option is only valid when ISBT 128 Concatenation is enabled .
ENTER/EXIT PROGRAMMING MODE ISBT 128 Concatenation Mode ISBT 128 Concatenation Mode Specifies the concatenation mode between Static and Dynamic. This option is only valid when ISBT 128 Concatenation is enabled (see page 162).
Code ISBT 128 ENTER/EXIT PROGRAMMING MODE ISBT 128 Dynamic Concatenation Timeout Specifies the timeout used by the ISBT 128 Dynamic Concatenation Mode.
ENTER/EXIT PROGRAMMING MODE Codablock F Enable/Disable CODABLOCK F The following options apply to the Codablock F symbology. Codablock F Enable/Disable Enables/Disables ability of reader to decode Codablock F labels. DEFAULT Codablock F = Disable Codablock F = Enable Codablock F EAN Enable/Disable Enables/Disables the Codablock F EAN subtype (code with FNC1 in the first position)..
Codablock F ENTER/EXIT PROGRAMMING MODE Codablock F AIM Check Specifies if Check Digit calculation algorithm is AIM compliant or not. Codablock F AIM Check = Disable DEFAULT Codablock F AIM Check = Enable Check C Codablock F Length Control This feature specifies either variable length decoding or fixed length decoding for the Codablock F symbology. Variable Length. For variable length decoding, a minimum and maximum length may be set. Fixed Length.
ENTER/EXIT PROGRAMMING MODE Codablock F Set Length 1 Codablock F Set Length 1 Specifies one of the barcode lengths for Codablock F Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the barcode’s data characters only. Characters can be set from 03 to 255 characters. Table 6 provides some examples for setting Length 1. See page 302 for detailed instructions on setting this feature. Table 6.
Codablock F ENTER/EXIT PROGRAMMING MODE Codablock F Set Length 2 This feature specifies one of the barcode lengths for Codablock F Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Length includes the barcode’s check, data, and full-ASCII shift characters. The length does not include start/stop characters. Table 7 provides examples for setting Length 2. See page 303 for detailed instructions on setting this feature.
ENTER/EXIT PROGRAMMING MODE I 2 of 5 Enable/Disable INTERLEAVED 2 OF 5 (I 2 OF 5) The following options apply to the I 2 of 5 symbology. I 2 of 5 Enable/Disable When disabled, the reader will not read I 2 of 5 barcodes. DEFAULT I 2 of 5 = Disable I 2 of 5 = Enable I 2 of 5 Check Character Calculation This option enables/disables calculation and verification of an optional I 2 of 5 check character.
Interleaved 2 of 5 (I 2 of 5) ENTER/EXIT PROGRAMMING MODE I 2 of 5 Check Character Calculation - cont. I 2 of 5 Check Character Calculation = Check DHL I 2 of 5 Check Character Calculation = Check Daimler Chrysler I 2 of 5 Check Character Calculation = Check Bosch I 2 of 5 Check Character Calculation = Italian Post I 2 of 5 Check Character Transmission Enable this option to transmit the check character along with I 2 of 5 barcode data.
ENTER/EXIT PROGRAMMING MODE I 2 of 5 Minimum Reads I 2 of 5 Minimum Reads This feature specifies the minimum number of consecutive times an I 2 of 5 label must be decoded before it is accepted as good read.
Interleaved 2 of 5 (I 2 of 5) ENTER/EXIT PROGRAMMING MODE 2 of 5 Decoding Level This configuration item applies to Interleaved 2 of 5, Datalogic 2 of 5 and Standard 2 of 5. Decoding Levels are used to configure a barcode symbology decoder to be very aggressive to very conservative depending on a particular customer’s needs. See page 302 for more information on this feature.
ENTER/EXIT PROGRAMMING MODE I 2 of 5 Length Control I 2 of 5 Length Control This feature specifies either variable length decoding or fixed length decoding for the I 2 of 5 symbology. Variable Length. For variable length decoding, a minimum and maximum length may be set. Fixed Length. For fixed length decoding, two different lengths may be set.
Interleaved 2 of 5 (I 2 of 5) ENTER/EXIT PROGRAMMING MODE I 2 of 5 Set Length 1 This feature specifies one of the barcode lengths for I 2 of 5 Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. The length includes the barcode’s check and data characters. The length can be set from 2 to 50 characters in increments of two. Table 8 provides some examples for setting Length 1.
ENTER/EXIT PROGRAMMING MODE I 2 of 5 Set Length 2 I 2 of 5 Set Length 2 This feature specifies one of the barcode lengths for I 2 of 5 Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. The length includes the barcode’s check and data characters. The length can be set from 2 to 50 characters. A setting of 0 specifies to ignore this length (only one fixed length). Table 9 provides examples for setting Length 2.
Interleaved 2 of 5 (I 2 of 5) ENTER/EXIT PROGRAMMING MODE I 2 of 5 Character Correlation When correlation is enabled, the barcode reader will combine label data from multiple scans when decoding. Enabling correlation will help the scanner read labels that have some spots and/ or voids. It may also help read labels that have damaged areas. Enabling correlation will also increase the chances that a label will be read incorrectly.
ENTER/EXIT PROGRAMMING MODE Follett 2 of 5 Enable/Disable FOLLETT 2 OF 5 The following options apply to the Follett 2 of 5 symbology. Follett 2 of 5 Enable/Disable Enables/Disables ability of imager to decode Follett 2 of 5 labels. DEFAULT Follett 2 of 5 = Disable Follett 2 of 5 = Enable INTERLEAVED 2 OF 5 CIP HR The following options apply to the Interleaved 2 of 5 CIP HR symbology.
Standard 2 of 5 ENTER/EXIT PROGRAMMING MODE STANDARD 2 OF 5 The following options apply to the Standard 2 of 5 symbology. Standard 2 of 5 Enable/Disable When disabled, the reader will not read Standard 2 of 5 barcodes. DEFAULT Standard 2 of 5 = Disable Standard 2 of 5 = Enable Standard 2 of 5 Check Character Calculation This option enables/disables calculation and verification of an optional Standard 2 of 5 check character.
ENTER/EXIT PROGRAMMING MODE Standard 2 of 5 Check Character Transmission Standard 2 of 5 Check Character Transmission This feature enables/disables transmission of an optional Standard 2 of 5 check character. Standard 2 of 5 Check Character Transmission = Don’t Send DEFAULT Standard 2 of 5 Check Character Transmission = Send Standard 2 of 5 Minimum Reads This feature specifies the minimum number of consecutive times a Standard 2 of 5 label must be decoded before it is accepted as good read.
Standard 2 of 5 ENTER/EXIT PROGRAMMING MODE Standard 2 of 5 Decoding Level The Standard 2 of 5 Decoding Level feature is set using "2 of 5 Decoding Level" on page 172. Standard 2 of 5 Length Control This feature specifies either variable length decoding or fixed length decoding for the Standard 2 of 5 symbology. Variable Length. For variable length decoding, a minimum and maximum length may be set. Fixed Length. For fixed length decoding, two different lengths may be set.
ENTER/EXIT PROGRAMMING MODE Standard 2 of 5 Set Length 1 Standard 2 of 5 Set Length 1 This feature specifies one of the barcode lengths for Standard 2 of 5 Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the barcode’s check and data characters. The length can be set from 1 to 50 characters. Table 10 provides some examples for setting Length 1.
Standard 2 of 5 ENTER/EXIT PROGRAMMING MODE Standard 2 of 5 Set Length 2 This feature specifies one of the barcode lengths for Standard 2 of 5 Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Length includes the barcode’s check and data characters. The length can be set from 1 to 50 characters. A setting of 0 specifies to ignore this length (only one fixed length). Table 11 provides examples for setting Length 2.
ENTER/EXIT PROGRAMMING MODE Standard 2 of 5 Character Correlation Standard 2 of 5 Character Correlation When correlation is enabled, the barcode reader will combine label data from multiple scans when decoding. Enabling correlation will help the scanner read labels that have some spots and/ or voids. It may also help read labels that have damaged areas. Enabling correlation will also increase the chances that a label will be read incorrectly.
Industrial 2 of 5 ENTER/EXIT PROGRAMMING MODE INDUSTRIAL 2 OF 5 The following options apply to the Industrial 2 of 5 symbology. Industrial 2 of 5 Enable/Disable Enables/Disables ability of reader to decode Industrial 2 of 5 labels. DEFAULT Industrial 2 of 5 = Disable Industrial 2 of 5 = Enable Industrial 2 of 5 Check Character Calculation Enables/Disables calculation and verification of an optional Industrial 2 of 5 check character.
ENTER/EXIT PROGRAMMING MODE Industrial 2 of 5 Check Character Transmission Industrial 2 of 5 Check Character Transmission Enables/disables transmission of an Industrial 2 of 5 check character. Industrial 2 of 5 Check Character Transmission = Disable DEFAULT Industrial 2 of 5 Check Character Transmission = Enable Industrial 2 of 5 Length Control This feature specifies either variable length decoding or fixed length decoding for the Industrial 2 of 5 symbology. Variable Length.
Industrial 2 of 5 ENTER/EXIT PROGRAMMING MODE Industrial 2 of 5 Set Length 1 This feature specifies one of the barcode lengths for Industrial 2 of 5 Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the barcode’s data characters only. The length can be set from 0 to 50 characters. Table 12 provides some examples for setting Length 1. See page 302 if you want detailed instructions on setting this feature.
ENTER/EXIT PROGRAMMING MODE Industrial 2 of 5 Set Length 2 Industrial 2 of 5 Set Length 2 This feature specifies one of the barcode lengths for Industrial 2 of 5 Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Length includes the barcode’s check, data, and full-ASCII shift characters. The length does not include start/stop characters. The length can be set from 1 to 50 characters.
Industrial 2 of 5 ENTER/EXIT PROGRAMMING MODE Industrial 2 of 5 Minimum Reads This feature specifies the minimum number of consecutive times an Industrial 2 of 5 label must be decoded before it is accepted as good read. DEFAULT Industrial 2 of 5 Minimum Reads = 1 Industrial 2 of 5 Minimum Reads = 2 Industrial 2 of 5 Minimum Reads = 3 Industrial 2 of 5 Minimum Reads = 4 Industrial 2 of 5 Stitching Enables/disables fixed length stitching for Industrial 2 of 5.
ENTER/EXIT PROGRAMMING MODE Industrial 2 of 5 Character Correlation Industrial 2 of 5 Character Correlation Enable/disables character correlation for Industrial 2 of 5.
Code IATA ENTER/EXIT PROGRAMMING MODE CODE IATA The following options apply to the IATA symbology. IATA Enable/Disable Enables/Disables the ability of the reader to decode IATA labels. DEFAULT IATA = Disable IATA = Enable IATA Check Character Transmission Enables/Disables calculation and verification of an optional Industrial 2 of 5 check character.
ENTER/EXIT PROGRAMMING MODE Datalogic 2 of 5 Enable/Disable DATALOGIC 2 OF 5 The following options apply to the Datalogic 2 of 5 symbology. Datalogic 2 of 5 Enable/Disable When disabled, the reader will not read Datalogic 2 of 5 barcodes. DEFAULT Datalogic 2 of 5 = Disable Datalogic 2 of 5 = Enable Datalogic 2 of 5 Check Character Calculation This option enables/disables calculation and verification of an optional Datalogic 2 of 5 check character.
Datalogic 2 of 5 ENTER/EXIT PROGRAMMING MODE Datalogic 2 of 5 Minimum Reads This feature specifies the minimum number of consecutive times an Datalogic 2 of 5 label must be decoded before it is accepted as good read. I 2 of 5 Minimum Reads = 1 DEFAULT I 2 of 5 Minimum Reads = 2 I 2 of 5 Minimum Reads = 3 I 2 of 5 Minimum Reads = 4 Datalogic 2 of 5 Decoding Level The Datalogic 2 of 5 Decoding Level feature is set using "2 of 5 Decoding Level" on page 172.
ENTER/EXIT PROGRAMMING MODE Datalogic 2 of 5 Length Control Datalogic 2 of 5 Length Control This feature specifies either variable length decoding or fixed length decoding for the Datalogic 2 of 5 symbology. Variable Length. For variable length decoding, a minimum and maximum length may be set. Fixed Length. For fixed length decoding, two different lengths may be set.
Datalogic 2 of 5 ENTER/EXIT PROGRAMMING MODE Datalogic 2 of 5 Set Length 1 This feature specifies one of the barcode lengths for Datalogic 2 of 5 Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. The length includes the barcode’s check and data characters. The length can be set from 2 to 50 characters in increments of two. Table 14 provides some examples for setting Length 1.
ENTER/EXIT PROGRAMMING MODE Datalogic 2 of 5 Set Length 2 Datalogic 2 of 5 Set Length 2 This feature specifies one of the barcode lengths for Datalogic 2 of 5 Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. The length includes the barcode’s check and data characters. The length can be set from 2 to 50 characters. A setting of 0 specifies to ignore this length (only one fixed length).
Datalogic 2 of 5 ENTER/EXIT PROGRAMMING MODE Datalogic 2 of 5 Character Correlation When correlation is enabled, the barcode reader will combine label data from multiple scans when decoding. Enabling correlation will help the scanner read labels that have some spots and/ or voids. It may also help read labels that have damaged areas. Enabling correlation will also increase the chances that a label will be read incorrectly.
ENTER/EXIT PROGRAMMING MODE Codabar Enable/Disable CODABAR The following options apply to the Codabar symbology. Codabar Enable/Disable When disabled, the reader will not read Codabar barcodes. DEFAULT Codabar = Disable Codabar = Enable Codabar Check Character Calculation Enable this option to enables/disables calculation and verification of an optional Codabar check character.
Codabar ENTER/EXIT PROGRAMMING MODE Codabar Check Character Transmission Enable this option to transmit the check character along with Codabar barcode data. Codabar Check Character Transmission = Don’t Send DEFAULT Codabar Check Character Transmission = Send Codabar Start/Stop Character Transmission Enable this option to enable/disable transmission of Codabar start and stop characters.
ENTER/EXIT PROGRAMMING MODE Codabar Start/Stop Character Set Codabar Start/Stop Character Set This option specifies the format of transmitted Codabar start/stop characters. Codabar Check Character Set = ABCD/TN*E Codabar Check Character Set = ABCD/ABCD Codabar Check Character Set = abcd/tn*e DEFAULT Codabar Check Character Set = abcd/abcd Codabar Start/Stop Character Match When enabled, this option requires that start and stop characters match.
Codabar ENTER/EXIT PROGRAMMING MODE Codabar Quiet Zones Specifies the number of quiet zones for Codabar labels. Quiet zones are blank areas at the ends of a barcode and are typically 10 times the width of the narrowest bar or space in the label.
ENTER/EXIT PROGRAMMING MODE Codabar Minimum Reads Codabar Minimum Reads This feature specifies the minimum number of consecutive times a Codabar label must be decoded before it is accepted as good read.
Codabar ENTER/EXIT PROGRAMMING MODE Codabar Decoding Level Decoding Levels are used to configure a barcode symbology decoder to be very aggressive to very conservative, depending on a particular customer’s needs. See page 302 for more information on this feature.
ENTER/EXIT PROGRAMMING MODE Codabar Length Control Codabar Length Control This feature specifies either variable length decoding or fixed length decoding for the Codabar symbology. Variable Length. For variable length decoding, a minimum and maximum length may be set. Fixed Length. For fixed length decoding, two different lengths may be set.
Codabar ENTER/EXIT PROGRAMMING MODE Codabar Set Length 1 This feature specifies one of the barcode lengths for Codabar Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the barcode’s start, stop, check and data characters. The length must include at least one data character. The length can be set from 3 to 50 characters. Table 16 provides some examples for setting Length 1.
ENTER/EXIT PROGRAMMING MODE Codabar Set Length 2 Codabar Set Length 2 This feature specifies one of the barcode lengths for Codabar Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. The length includes the barcode’s start, stop, check and data characters. The length must include at least one data character. The length can be set from 3 to 50 characters. A setting of 0 specifies to ignore this length (only one fixed length).
Codabar ENTER/EXIT PROGRAMMING MODE Codabar Interdigit Ratio This feature specifies the ratio between an intercharacter space and module for Codabar labels.
ENTER/EXIT PROGRAMMING MODE Codabar Interdigit Ratio Codabar Interdigit Ratio — cont.
Codabar ENTER/EXIT PROGRAMMING MODE Codabar Character Correlation When correlation is enabled, the barcode reader will combine label data from multiple scans when decoding. Enabling correlation will help the scanner read labels that have some spots and/ or voids. It may also help read labels that have damaged areas. Enabling correlation will also increase the chances that a label will be read incorrectly.
ENTER/EXIT PROGRAMMING MODE ABC Codabar Enable/Disable ABC CODABAR The following options apply to the ABC Codabar symbology. ABC Codabar Enable/Disable Enables/Disables ability of reader to decode ABC Codabar labels. DEFAULT ABC Codabar = Disable ABC Codabar = Enable ABC Codabar Concatenation Mode Specifies the concatenation mode between Static and Dynamic.
ABC Codabar ENTER/EXIT PROGRAMMING MODE ABC Codabar Dynamic Concatenation Timeout Specifies the timeout in 10-millisecond ticks used by the ABC Codabar Dynamic Concatenation Mode.
ENTER/EXIT PROGRAMMING MODE ABC Codabar Force Concatenation ABC Codabar Force Concatenation Forces labels starting or ending with D to be concatenated.
Code 11 ENTER/EXIT PROGRAMMING MODE CODE 11 The following options apply to the Code 11 symbology. Code 11 Enable/Disable When disabled, the reader will not read Code 11 barcodes. DEFAULT Code 11 = Disable Code 11 = Enable Code 11 Check Character Calculation This option enables/disables calculation and verification of optional Code 11 check character.
ENTER/EXIT PROGRAMMING MODE Code 11 Check Character Transmission Code 11 Check Character Transmission This feature enables/disables transmission of an optional Code 11 check character. Code 11 Check Character Transmission = Don’t Send DEFAULT Code 11 Check Character Transmission = Send Code 11 Minimum Reads This feature specifies the minimum number of consecutive times a Code 11 label must be decoded before it is accepted as good read.
Code 11 ENTER/EXIT PROGRAMMING MODE Code 11 Length Control This feature specifies either variable length decoding or fixed length decoding for the Code 11 symbology. Variable Length. For variable length decoding, a minimum and maximum length may be set. Fixed Length. For fixed length decoding, two different lengths may be set.
ENTER/EXIT PROGRAMMING MODE Code 11 Set Length 1 Code 11 Set Length 1 This feature specifies one of the barcode lengths for Code 11 Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the barcode’s check and data characters. The length can be set from 2 to 50 characters. Table 18 provides some examples for setting Length 1. See page 302 for detailed instructions on setting this feature. Table 18.
Code 11 ENTER/EXIT PROGRAMMING MODE Code 11 Set Length 2 This feature specifies one of the barcode lengths for Code 11 Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Length includes the barcode’s check and data characters. The length can be set from 2 to 50 characters. A setting of 0 specifies to ignore this length (only one fixed length). Table 19 provides examples for setting Length 2.
ENTER/EXIT PROGRAMMING MODE Code 11 Interdigit Ratio Code 11 Interdigit Ratio This feature specifies the ratio between an intercharacter space and module for Code 11 labels.
Code 11 ENTER/EXIT PROGRAMMING MODE Code 11 Interdigit Ratio — cont.
ENTER/EXIT PROGRAMMING MODE Code 11 Decoding Level Code 11 Decoding Level Decoding Levels are used to configure a barcode symbology decoder to be very aggressive to very conservative depending on a particular customer’s needs. See page 302 for more information on this feature.
Code 11 ENTER/EXIT PROGRAMMING MODE Code 11 Character Correlation When correlation is enabled, the barcode reader will combine label data from multiple scans when decoding. Enabling correlation will help the scanner read labels that have some spots and/ or voids. It may also help read labels that have damaged areas. Enabling correlation will also increase the chances that a label will be read incorrectly.
ENTER/EXIT PROGRAMMING MODE GS1 DataBar™ Omnidirectional Enable/Disable GS1 DATABAR™ OMNIDIRECTIONAL The following options apply to the GS1 DataBar™ Omnidirectional (formerly RSS-14) symbology. GS1 DataBar™ Omnidirectional Enable/Disable When disabled, the reader will not read GS1 DataBar™ Omnidirectional barcodes.
GS1 DataBar™ Omnidirectional ENTER/EXIT PROGRAMMING MODE GS1 DataBar™ Omnidirectional Minimum Reads This feature specifies the minimum number of consecutive times a GS1 DataBar™ Omnidirectional label must be decoded before it is accepted as good read.
ENTER/EXIT PROGRAMMING MODE GS1 DataBar™ Expanded Enable/Disable GS1 DATABAR™ EXPANDED The following options apply to the GS1 DataBar™ Expanded (formerly RSS Expanded) symbology. GS1 DataBar™ Expanded Enable/Disable When disabled, the reader will not read GS1 DataBar™ Expanded barcodes. DEFAULT GS1 DataBar™ Expanded = Disable GS1 DataBar™ Expanded = Enable GS1 DataBar™ Expanded GS1-128 Emulation When enabled, GS1 DataBar™ Expanded barcodes will be translated to the GS1-128 label data format.
GS1 DataBar™ Expanded ENTER/EXIT PROGRAMMING MODE GS1 DataBar™ Expanded Minimum Reads This feature specifies the minimum number of consecutive times a GS1 DataBar™ Expanded label must be decoded before it is accepted as good read.
ENTER/EXIT PROGRAMMING MODE GS1 DataBar™ Expanded Set Length 1 GS1 DataBar™ Expanded Set Length 1 This feature specifies one of the barcode lengths for GS1 DataBar™ Expanded Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the barcode’s data characters only. The length can be set from 1 to 74 characters. Table 20 provides some examples for setting Length 1.
GS1 DataBar™ Expanded ENTER/EXIT PROGRAMMING MODE GS1 DataBar™ Expanded Set Length 2 This feature specifies one of the barcode lengths for GS1 DataBar™ Expanded Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Length includes the barcode’s data characters only. The length can be set from 1 to 74 characters. A setting of 0 specifies to ignore this length (only one fixed length).
ENTER/EXIT PROGRAMMING MODE GS1 DataBar™ Limited Enable/Disable GS1 DATABAR™ LIMITED The following options apply to the GS1 DataBar™ Limited (formerly RSS Limited) symbology. GS1 DataBar™ Limited Enable/Disable When disabled, the reader will not read GS1 DataBar™ Limited barcodes. DEFAULT GS1 DataBar™ Limited = Disable GS1 DataBar™ Limited = Enable GS1 DataBar™ Limited GS1-128 Emulation When enabled, GS1 DataBar™ Limited barcodes will be translated to the GS1-128 label data format.
GS1 DataBar™ Limited ENTER/EXIT PROGRAMMING MODE GS1 DataBar™ Limited Minimum Reads This feature specifies the minimum number of consecutive times a GS1 DataBar™ Limited label must be decoded before it is accepted as good read.
ENTER/EXIT PROGRAMMING MODE Code 93 Enable/Disable CODE 93 The following options apply to the Code 93 symbology. Code 93 Enable/Disable Enables/Disables ability of reader to decode Code 93 labels. DEFAULT Code 93 = Disable Code 93 = Enable Code 93 Check Character Calculation Enables/disables calculation and verification of an optional Code 93 check character.
Code 93 ENTER/EXIT PROGRAMMING MODE Code 93 Check Character Transmission Enables/disables transmission of an optional Code 93 check character. DEFAULT Code 93 Check Character Transmission = Disable Code 93 Check Character Transmission = Enable Code 93 Length Control This feature specifies either variable length decoding or fixed length decoding for the Code 93 symbology. Variable Length. For variable length decoding, a minimum and maximum length may be set. Fixed Length.
ENTER/EXIT PROGRAMMING MODE Code 93 Set Length 1 Code 93 Set Length 1 Specifies one of the barcode lengths for Code 93 Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the barcode’s data characters only. The length can be set from 01 to 50 characters. Table 22 provides some examples for setting Length 1. See page 302 for detailed instructions on setting this feature. Table 22.
Code 93 ENTER/EXIT PROGRAMMING MODE Code 93 Set Length 2 This feature specifies one of the barcode lengths for Code 93 Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Length includes the barcode’s check, data, and full-ASCII shift characters. The length does not include start/stop characters. The length can be set from 1 to 50 characters. A setting of 0 specifies to ignore this length (only one fixed length).
ENTER/EXIT PROGRAMMING MODE Code 93 Minimum Reads Code 93 Minimum Reads This feature specifies the minimum number of consecutive times a Code 93 label must be decoded before it is accepted as good read.
Code 93 ENTER/EXIT PROGRAMMING MODE Code 93 Decoding Level Specifies the decoding level for Code 93. Decoding Levels are used to configure a barcode symbology decoder to be very aggressive to very conservative depending on a particular customer’s needs. See page 302 for more information on this feature.
ENTER/EXIT PROGRAMMING MODE Code 93 Quiet Zones Code 93 Quiet Zones Enables/disables quiet zones for Code 93.
Code 93 ENTER/EXIT PROGRAMMING MODE Code 93 Stitching Disable/enable fixed or variable length stitching for Code 93. Code 93 Stitching = Disable DEFAULT Code 93 Stitching = Enable Code 93 Character Correlation Enables/disables Character Correlation for Code 93.
ENTER/EXIT PROGRAMMING MODE MSI Enable/Disable MSI The following options apply to the MSI symbology. MSI Enable/Disable Enables/Disables ability of reader to decode MSI labels. DEFAULT MSI = Disable MSI = Enable MSI Check Character Calculation Enables/Disables calculation and verification of an optional MSI check character.
MSI ENTER/EXIT PROGRAMMING MODE MSI Check Character Transmission Enables/disables transmission of an MSI check character. MSI Check Character Transmission = Disable DEFAULT MSI Check Character Transmission = Enable MSI Length Control This feature specifies either variable length decoding or fixed length decoding for the MSI symbology. Variable Length. For variable length decoding, a minimum and maximum length may be set. Fixed Length. For fixed length decoding, two different lengths may be set.
ENTER/EXIT PROGRAMMING MODE MSI Set Length 1 MSI Set Length 1 This feature specifies one of the barcode lengths for MSI Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the barcode’s data characters only. The length can be set from 01 to 50 characters. Table 24 provides some examples for setting Length 1. See page 302 for detailed instructions on setting this feature. Table 24.
MSI ENTER/EXIT PROGRAMMING MODE MSI Set Length 2 This feature specifies one of the barcode lengths for MSI Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Length includes the barcode’s check, data, and full-ASCII shift characters. The length does not include start/stop characters. The length can be set from 1 to 50 characters. A setting of 0 specifies to ignore this length (only one fixed length).
ENTER/EXIT PROGRAMMING MODE MSI Minimum Reads MSI Minimum Reads This feature specifies the minimum number of consecutive times an MSI label must be decoded before it is accepted as good read.
MSI ENTER/EXIT PROGRAMMING MODE MSI Decoding Level Specifies the decoding level for MSI. Decoding Levels are used to configure a barcode symbology decoder to be very aggressive to very conservative depending on a particular customer’s needs. See page 302 for more information on this feature.
ENTER/EXIT PROGRAMMING MODE Plessey Enable/Disable PLESSEY The following options apply to the Plessey symbology. Plessey Enable/Disable Enables/Disables ability of reader to decode Plessey labels.
Plessey ENTER/EXIT PROGRAMMING MODE Plessey Check Character Calculation Enables/Disables calculation and verification of an optional Plessey check character. Plessey Check Character Calculation = Disable DEFAULT Plessey Check Character Calculation = Enable Plessey std. check char. verification Plessey Check Character Calculation = Enable Anker check char. verification Plessey Check Character Calculation = Enable Plessey std.
ENTER/EXIT PROGRAMMING MODE Plessey Length Control Plessey Length Control This feature specifies either variable length decoding or fixed length decoding for the Plessey symbology. Variable Length. For variable length decoding, a minimum and maximum length may be set. Fixed Length. For fixed length decoding, two different lengths may be set.
Plessey ENTER/EXIT PROGRAMMING MODE Plessey Set Length 1 This feature specifies one of the barcode lengths for Plessey Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the barcode’s data characters only. The length can be set from 01 to 50 characters. Table 26 provides some examples for setting Length 1. See page 302 for detailed instructions on setting this feature. Table 26.
ENTER/EXIT PROGRAMMING MODE Plessey Set Length 2 Plessey Set Length 2 This feature specifies one of the barcode lengths for Plessey Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Length includes the barcode’s check, data, and full-ASCII shift characters. The length does not include start/stop characters. The length can be set from 1 to 50 characters. A setting of 0 specifies to ignore this length (only one fixed length).
Plessey ENTER/EXIT PROGRAMMING MODE Plessey Minimum Reads This feature specifies the minimum number of consecutive times a Plessey label must be decoded before it is accepted as good read.
ENTER/EXIT PROGRAMMING MODE Plessey Decoding Level Plessey Decoding Level Specifies the decoding level for Plessey. Decoding Levels are used to configure a barcode symbology decoder to be very aggressive to very conservative depending on a particular customer’s needs. See page 302 for more information on this feature.
Plessey ENTER/EXIT PROGRAMMING MODE Plessey Stitching Enables/disables fixed length stitching for Plessey. DEFAULT Plessey Stitching = Disable Plessey Stitching = Enable Plessey Character Correlation Enables/disables Character Correlation for Plessey.
ENTER/EXIT PROGRAMMING MODE Code 4 Enable/Disable CODE 4 The following options apply to the Code 4 symbology. Code 4 Enable/Disable Enables/Disables ability of imager to decode Code 4 labels. DEFAULT Code 4 = Disable Code 4 = Enable Code 4 Check Character Transmission This feature enables/disables transmission of an optional Code 4 check character.
Code 5 ENTER/EXIT PROGRAMMING MODE Code 4 Hex to Decimal Conversion This feature enables/disables the conversion of hexidecimal label data to decimal label data. Code 4 Hex to Decimal Conversion = Disable DEFAULT Code 4 Hex to Decimal Conversion = Enable CODE 5 The following options apply to the Code 5 symbology. Code 5 Enable/Disable Enables/Disables ability of imager to decode Code 5 labels.
ENTER/EXIT PROGRAMMING MODE Code 5 Check Character Transmission Code 5 Check Character Transmission This feature enables/disables transmission of an optional Code 5 check character. Code 5 Check Character Transmission = Don’t Send DEFAULT Code 5 Check Character Transmission = Send Code 5 Hex to Decimal Conversion This feature enables/disables the conversion of hexidecimal label data to decimal label data.
Code 4 and Code 5 Common Configuration Items ENTER/EXIT PROGRAMMING MODE CODE 4 AND CODE 5 COMMON CONFIGURATION ITEMS The following options apply to both Code 4 and Code 5 symbologies. Code 4 and 5 Decoding Level Decoding Levels are used to configure a barcode symbology decoder to be very aggressive to very conservative depending on a particular customer’s needs. See page 291 for more information on this feature. This configuration item applies to Code 4 and Code 5.
ENTER/EXIT PROGRAMMING MODE Code 4 and Code 5 Minimum Reads Code 4 and Code 5 Minimum Reads This feature specifies the minimum number of consecutive times a Code 4 or Code 5 label must be decoded before it is accepted as good read.
Code 4 and Code 5 Common Configuration Items ENTER/EXIT PROGRAMMING MODE NOTES 256 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300
Chapter 4 Wireless Features The features in this section are valid only for the GM4100 and GBT4100 models. This section provides options and programming related to the reader’s STAR and Bluetooth communication features. Reference Appendix B, Standard Defaults for a listing of standard factory settings.
ENTER/EXIT PROGRAMMING MODE FEATURES FOR STAR MODELS ONLY starting on page 272 • STAR Radio Protocol Timeout • STAR Radio Transmit Mode DISPLAY FEATURES starting on page 274 • Contrast • Display Mode • Font Size • Display Timeout • Backlight • Keypad Select BLUETOOTH-ONLY FEATURES starting on page 279 BT SECURITY FEATURES • BT Security Mode • Select PIN Code Length • BT Pin Code • Set PIN Code BT HID Send Unkown ASCII Char BT HID FEATURES • BT HID Variable PIN Code • • BT HID A
ENTER/EXIT PROGRAMMING MODE Good Transmission Beep WIRELESS BEEPER FEATURES Several options are available to configure beeper behavior for RF operation. Good Transmission Beep Enables/disables the Good Transmission Beep indication. When enabled, a beep occurs when a Label is correctly transmitted to the base.
Wireless Beeper Features ENTER/EXIT PROGRAMMING MODE Beep Duration This feature controls the duration of radio-specific beep indications.
ENTER/EXIT PROGRAMMING MODE Beep Volume Beep Volume Selects the beeper volume (loudness) of radio-specific beep indications. There are three selectable volume levels. Beep Volume = Low Beep Volume = Medium DEFAULT Beep Volume = High Disconnect Beep Enables/disables the beep indication that a handheld has become connected or disconnected from a Base Station. The defaults are different for the STAR and BT models.
Wireless Beeper Features ENTER/EXIT PROGRAMMING MODE Base Station Beep Enables/disables a beep indication when the handheld is placed in the Base Station. BT Base Station Beep = Disable DEFAULT BT Base Station Beep = Enable Leash Alarm This setting specifies the number of seconds to sound the Leash Mode beeps (three per second) when the handheld goes out of range. This is especially useful in instances where the reader might inadvertently have been placed in a bag or cart.
ENTER/EXIT PROGRAMMING MODE Leash Alarm Leash Alarm — cont.
Configuration Updates ENTER/EXIT PROGRAMMING MODE CONFIGURATION UPDATES See page 318 in “References” for detailed information and examples of these features. Automatic Configuration Update When this feature is enabled, a reader and its linked Base Station can automatically ensure they stay in sync with regard to application hardware and/or configuration. See page 318 for more information on this feature.
ENTER/EXIT PROGRAMMING MODE Copy Configuration to Base Station Copy Configuration to Base Station Scan the following label to copy the current scanner configuration to the Base Station. Use this method when the Auto Configuration Update feature is disabled and you want a one-time configuration update to be performed on the Base Station. Copy Configuration to Base Station Do not scan an ENTER/EXIT PROGRAMMING MODE label with this barcode.
Configuration Updates ENTER/EXIT PROGRAMMING MODE Request Flash Update Scan this barcode to request a flash update from a Base Station Do not scan an ENTER/EXIT PROGRAMMING MODE label in conjunction with this barcode. NOTE Request Flash Update Powerdown Timeout The Powerdown Timeout feature sets the time for automatically switching the unit off when the imager has been idle.
ENTER/EXIT PROGRAMMING MODE Powerdown Timeout Powerdown Timeout — continued Powerdown Timeout = 60 Minutes (1 Hour) Powerdown Timeout = 120 Minutes (2 Hours) Powerdown Timeout = 4 Hours Powerdown Timeout = 6 Hours Powerdown Timeout = 8 Hours Powerdown Timeout = 16 Hours Powerdown Timeout = 24 Hours Product Reference Guide 267
Batch Features ENTER/EXIT PROGRAMMING MODE BATCH FEATURES Batch Mode This option specifies whether to store labels in the handheld while disconnected from the base. Options are as follows: • Disabled — The handheld will not store/batch labels. • • Automatic — The handheld will store labels to RAM when the handheld goes out of range and is disconnected from the remote device. Manual — The handheld will always store labels to Flash memory.
ENTER/EXIT PROGRAMMING MODE Erase Batch Memory Erase Batch Memory Use this barcode to erase any labels stored in batch memory. Do not scan an ENTER/EXIT PROGRAMMING MODE label in conjunction with this barcode. Erase Batch Memory RF Batch Mode Transmit Delay Specifies the delay in 10 msec increments between transmitting labels stored in batch memory .
Direct Radio AutoLink ENTER/EXIT PROGRAMMING MODE DIRECT RADIO AUTOLINK This feature enables/disables the ability to link a wireless handheld to a base station without scanning the Unlink label first. DEFAULT Direct Radio Link = Unlink Label Required Direct Radio Link = Automatic Unlinking RF ADDRESS STAMPING These features allow configuration of source radio data inclusion.
ENTER/EXIT PROGRAMMING MODE Source Radio Address Delimiter Character Source Radio Address Delimiter Character This option specifies the delimiter character to be placed between the label data and radio address when address stamping is enabled. This feature only applies if "Source Radio Address Transmission" on page 270 is enabled. Set Source Radio Address Delimiter Character Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning.
RF Address Stamping ENTER/EXIT PROGRAMMING MODE Features for Star Models Only The features in this section are valid only for the Gryphon I GM4100 Star model: • STAR Radio Protocol Timeout • STAR Radio Transmit Mode DISPLAY FEATURES starting on page 274 • • • • • • Contrast Font Size Backlight Display Mode Display Timeout Keypad Select STAR Radio Protocol Timeout This parameter sets the valid wait time before transmission between the handheld reader and Base Station is considered failed.
ENTER/EXIT PROGRAMMING MODE STAR Radio Transmit Mode STAR Radio Transmit Mode Specifies the transmission protocol for Star communications.
Display Features ENTER/EXIT PROGRAMMING MODE DISPLAY FEATURES Contrast Read the code until the desired contrast is reached.
ENTER/EXIT PROGRAMMING MODE Backlight Backlight DEFAULT Display$backlight = off Display $ backlight = on Display Mode The user can control the reader display behavior according to various selections. See page 318 in “References” for detailed information about each feature.
Display Features ENTER/EXIT PROGRAMMING MODE Display Timeout Specifies how long the display will remain on after a display write. Display is forced on after any display write or after any reading phase. Display and backlight are turned off after this timeout expires.
ENTER/EXIT PROGRAMMING MODE Display Timeout Display Timeout - cont. $ Display Timeout = 5 Seconds Display Timeout= 6 Seconds Display Timeout = 7 Seconds DEFAULT Display Timeout = 8 Seconds Display Timeout = 9 Seconds Display Timeout$= 9.9 Seconds (9,900ms max.
Display Features ENTER/EXIT PROGRAMMING MODE Keypad Select This parameter specifies the character that has to be sent from the scanner when one of the three keys are pressed. For example, when key1 is pressed a 0x3C '<' character is sent. Follow these instructions to set this feature: 1. Determine the desired setting. 2. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming Mode. 3. Scan the barcode: DISPLAY KEYPAD SELECT. 4.
ENTER/EXIT PROGRAMMING MODE Keypad Select Bluetooth-Only Features The features in this section are valid only for Gryphon Bluetooth models. Also reference the Setup section for instructions on Linking a BT Reader to a PC, starting on page 26.
BT Security Features ENTER/EXIT PROGRAMMING MODE BT SECURITY FEATURES The BT system can be set up to require a configurable PIN code to authenticate/connect BT devices, and encrypt the data. This can be done in one of two ways: • The scanner can be programmed with a PIN code using the bar codes in this section. • The Host can be set up to specify a custom security PIN code when a scanner attempts to connect. For more information about this feature, contact Datalogic Technical Support.
BT Pin Code BT Pin Code After enabling Security Mode (see "BT Security Mode on page 280), specify whether you want to set a 4-digit or a 16-digit PIN Code. See page 321 for detailed information and examples for setting this feature. Select PIN Code Length DEFAULT Select 4-character BT PIN Code Select 16-character BT PIN Code Set PIN Code Determine the desired characters for the PIN code, then convert to hexadecimal using the ASCII Chart on the inside back cover of this manual.
BT HID Features BT HID FEATURES BT HID Variable PIN Code This feature specifies the selection available for Static or Variable Pin Code, when BT HID profile is configured. DEFAULT Use Static PIN Code Use Variable PIN Code BT HID ALT Mode This feature Enables/Disables the ability to transmit correctly a label content to the host regardless of the BT HID Country Mode selected, when BT HID profile is configured.
BT HID Send Unkown BT HID Send Unkown ASCII Char This feature Enable/Disable the ability of a BT HH to transmit a label containing an unknown character to the host, when BT HID profile is configured.
Other BT Features OTHER BT FEATURES BT Poll Rate This feature specifies the time between BT polls.
BT Poll Rate BT Poll Rate (continued) BT Poll Rate = 150 ms BT Poll Rate = 200 ms BT Poll Rate = 500 ms BT Poll Rate = 990 ms Product Reference Guide 285
Other BT Features NOTES 286 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300
Chapter 5 Laser Features The features in this section are valid for the Gryphon L GD4300 model only. LASER SCAN ANGLE on page 288 LASER IDLE MODE on page 288 BI-DIRECTIONAL READ DECODING on page 289 ALWAYS ON SCAN MODE TIMEOUT on page 290 This section provides options and programming related to the reader’s laser features. Reference Appendix B, Standard Defaults for a listing of standard factory settings. For hands-free or stand operations, it is recommended that Flashing scan mode be used.
ENTER/EXIT PROGRAMMING MODE Laser Scan Angle This feature sets the scan angle for the laser. The Narrow scan angle is helpful for selecting and reading a specific barcode among a tight grouping of labels. DEFAULT Laser Scan Angle = Normal (47 degrees) Laser Scan Angle = Narrow (35 degrees) Laser Idle Mode Laser Idle Mode option is applicable for; trigger Single, Trigger Hold Multiple & Trigger Pulse Multiple only.
ENTER/EXIT PROGRAMMING MODE Bi-Directional Read Decoding Bi-Directional Read Decoding This configuration provides control over the good read and barcode label requirement. This programming option for Gyphon Laser affects all barcode symbologies. Bi-Directional Read Disable. When Bi-directional reading is disabled, the laser scan is only required to obtain a valid label read in one scanning direction. Bi-Directional Read Enable.
ENTER/EXIT PROGRAMMING MODE Always On Scan Mode Timeout When the Gryphon Laser is in Always On scanning mode, timeout periods can be configured. If the programmed Always On Timeout elapses, the reader will shut down and a trigger pull is required to resume operation.
Chapter 6 References This section contains explanations and examples of selected barcode features. See the Configuration section for the actual barcode labels used to configure the reader. RS-232 Parameters RS-232 Only Baud Rate Baud rate is the number of bits of data transmitted per second. Set the reader's baud rate to match the baud rate setting of the host device. With an improper baud rate setting, data may not reach the host correctly.
References • • RTS/XON/XOFF — RTS is asserted during transmissions. CTS is ignored. XON and XOFF gate transmissions. RTS On/CTS — RTS is always asserted. CTS gates transmissions. RTS/CTS Scan Control — RTS is asserted during transmissions. CTS gates transmissions and controls enable and disable state of scanner. RS-232/USB COM Parameters Intercharacter Delay This parameter specifies the intercharacter delay between the end of one character and the beginning of the next.
RS-232 Parameters ACK NAK Options This enables/disables the ability of the reader to support the RS-232 ACK/NAK protocol. When configured, the reader and/or host sends an “ACK” when it receives data properly, and sends “NAK” when the data is in error. Options are: • Disable • Enable for label transmission — The reader expects an ACK/NAK response from the host when a label is sent. • Enable for host-command acknowledge — The reader will respond with ACK/NAK when the host sends a command.
References NAK Character This setting specifies an ASCII character or hex value to be used as the NAK character. ASCII characters or any hex value from 0 to 0xFF can be selected. Setting to previously defined characters such as XON, XOFF, or host commands conflicts with normal operation of these characters. 8bit data is not recognized when the option Data Bits has been set as 7 Data Bits. To set this feature: 1. Determine the desired character or value. 2.
RS-232 Parameters ACK NAK Timeout Value This option specifies the amount of time the reader waits for an ACK character from the host following label transmission. The selectable timeout range is 200 milliseconds to 15,000ms (15 seconds) in 200ms increments. A selection of 0 disables the timeout. To set this value: 1. Determine the desired setting in milliseconds. 2. Divide the desired setting by 200 (setting is in 200ms increments). Pad the result with leading zeroes to yield two digits.
References ACK NAK Retry Count This feature specifies the number of times the reader retries a label transmission due to a retry condition. The selectable range is from 1 to 254 retries. A selection of 0 disables the count, and a selection of 255 specifies unlimited retries. To set this feature: 1. Determine the desired setting. 2. Pad the number with leading zeroes to yield three digits. For example: 0 = 000, 5 = 005, 20 = 020, etc. 3.
RS-232 Parameters Disable Character Specifies the value of the RS-232 host command used to disable the reader. ASCII characters or any hex value from 0 to 0xFF can be selected. Setting to previously defined characters such as XON, XOFF, or host commands conflicts with normal operation of these characters. 8bit data is not recognized when the option Data Bits has been set as 7 Data Bits. To set the value: 1. Determine the desired character or value.
References Enable Character Specifies the value of the RS-232 host command used to enable the reader. ASCII characters or any hex value from 0 to 0xFF can be selected. Setting to previously defined characters such as XON, XOFF, or host commands conflicts with normal operation of these characters. 8bit data is not recognized when the option Data Bits has been set as 7 Data Bits. To set this feature: Determine the desired character or value.
Keyboard Interface Keyboard Interface Wedge Quiet Interval Specifies the amount of time the reader looks for keyboard activity before it breaks the keyboard connection in order to transmit data to host. The range is from 0 to 990ms in 10ms increments. This feature applies ONLY to the Keyboard Wedge interface. 1. Determine the desired setting in milliseconds. 2. Divide the desired setting by 10 (setting is in 10ms increments). Pad the result with leading zeroes to yield two digits.
References Intercharacter Delay This parameter specifies the intercharacter delay between the end of one character and the beginning of the next. The delay can be set within a range of zero (0) to 990 milliseconds in 10ms increments. A setting of zero specifies no delay. This feature applies ONLY to the Keyboard Wedge interface. To set the delay: 1. Determine the desired setting in milliseconds. 2. Divide the desired setting by 10 (setting is in 10ms increments).
Keyboard Interface Intercode Delay Specifies the delay between labels transmitted to the host for this interface. The selectable range for this feature is from 0 to 99 seconds. Follow these instructions to set this feature: 1. Determine the desired setting. 2. Pad the number with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc 3. Go to page 64 and scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming Mode. 4. Scan the barcode: SELECT INTERCODE DELAY SETTING. 5.
References Symbologies Decoding Level Decoding Levels are used to configure a barcode symbology decoder to be very aggressive to very conservative depending on a particular customer’s needs. • Level 1 results in a very conservative decoder at the expense of not being able to read poorly printed or damaged labels. • Level 5 results in a very aggressive decoder. This aggressive behavior allows decoding of poorly printed and damaged labels at the expense of increasing the likelihood of decoding errors.
Symbologies Set Length 2 This feature allows you to set one of the barcode lengths for the specified symbology. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. See the page for the specific symbology for parameters. The length that can be set varies depending on the symbology. A setting of 0 specifies to ignore this length (only one fixed length). Follow these instructions to set this feature: 1.
References Data Editing It is not recommended to use these features with IBM interfaces. CAUTION When a barcode is scanned, additional information can be sent to the host computer along with the barcode data. This combination of barcode data and supplementary user-defined data is called a “message string.” The Data Editing features can be used to build specific user-defined data into a message string. There are several types of selectable data characters that can be sent before and after scanned data.
Data Editing Global Prefix/Suffix Up to 20 ASCII characters may be added as a prefix (in a position before the barcode data) and/ or as a suffix (in a position following the barcode data) as indicated in Figure 17. Figure 17. Prefix and Suffix Positions OR... Prefix Label ID AIM ID Bar Code Data Label ID Suffix 00 - 20 Characters (ASCII) AND OR Example: Setting a Prefix In this example, we’ll set a prefix for all symbologies. 1.
References Global AIM ID This feature enables/disables addition of AIM IDs for all symbology types. AIM label identifiers (as opposed to custom characters you select yourself as with label identifiers) can be included with scanned barcode data. AIM label identifiers consist of three characters as follows: • A close brace character (ASCII ‘]’), followed by... • A code character (see the table below), followed by... • A modifier character (the modifier character is symbol dependent).
Data Editing Label ID A Label ID is a customizable code of up to three ASCII characters (each can be one of hex 0x010xFF), used to identify a barcode (symbology) type. It can be appended previous to or following the transmitted barcode data depending upon how this option is enabled. This feature provides options for configuring custom Label IDs as a pre-loaded set (see "Label ID: Pre-loaded Sets" below) or individually per symbology (see "Label ID: Set Individually Per Symbology"on page 309).
References Label ID Pre-Loaded Sets (continued) Symbology USA Label ID set ASCII character Hexidecimal value ASCII character Hexidecimal value EAN8 FF 464600 A 410000 EAN8 P2 FF 464600 J 4A0000 EAN8 P5 FF 464600 K 4B0000 EAN8 P8 FF 464600 * 2A0000 FOLLETT 2OF5 O 4F0000 O 4F0000 GS1 DATABAR EXPANDED RX 525800 t 740000 GS1 DATABAR LIMITED RL 524C00 v 760000 GS1 DATABAR OMNIDIRECTIONAL R4 523400 u 750000 000000 k 6B0000 GS1-128 308 EU Label ID set GTIN G 470
Data Editing Label ID: Set Individually Per Symbology To configure a Label ID individually for a single symbology: 1. Go to page 81 and scan the ENTER/EXIT barcode. 2. Select Label ID position as either BEFORE (Enable as Prefix) or AFTER (Enable as suffix) by scanning the appropriate barcode in the section "Label ID Control"on page 82. Reference Figure 19 for Label ID positioning options if multiple identification features are enabled. 3.
References Table 39. Label ID Examples STEP ACTION EXAMPLES 1. Scan the ENTER/EXIT barcode (Scanner enters Programming Mode) 2. Determine placement of the Label ID characters BEFORE or AFTER with regard to scanned Enable as Prefix data using Label ID Control, starting on page 82 Enable as Suffix Enable as Prefix Enable as Suffix 3.
Data Editing Character Conversion Character conversion is an eight byte configuration item. The eight bytes are 4 character pairs represented in hexadecimal ASCII values. The first character in the pair is the character that will be converted. The second character in the pair is the character to convert to. If the character to convert in a pair is FF, then no conversion is done.
References Reading Parameters Label Gone Timeout This feature sets the time after the last label segment is seen before the reader prepares for a new label. The timeout can be set within a range of 10 milliseconds to 2,550 milliseconds (2.55 seconds) in 10ms increments. Label Gone Timeout does not apply to scan modes that require a trigger pull for each label that is read Follow these instructions to set this feature: 1. Determine the desired setting in milliseconds. 2.
Reading Parameters Good Read LED Duration This feature specifies the amount of time that the Good Read LED remains on following a good read. The good read LED on time can be set within a range of 10 milliseconds to 2,550 milliseconds (0.001 to 2.55 seconds) in 100ms increments. Follow these instructions to set this feature: 1. Determine the desired setting in milliseconds. A setting of 0 means that the good read LED stays on until the next time the trigger is pulled. 2.
References Scanning Features Scan Mode This mode is associated with typical handheld reader operation. Selects the scan operating mode for the reader. The following selections are valid for all models: Trigger Single. When the trigger is pulled, scanning is activated until one of the following occurs: - Scanning Active Time has elapsed - a label has been read - the trigger is released Trigger Hold Multiple.
Scanning Features Scanning Active Time This setting specifies the amount of time that the reader stays in scan ON state once the state is entered. The range for this setting is from 1 to 255 seconds in 1-second increments. Follow these instructions to set this feature: 1. Determine the desired setting. 2. Pad the result with leading zeroes to yield three digits. For example: 0 = 000, 5 = 005, 20 = 020, etc. 3. Go to page 104 and scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming Mode. 4.
References Flash On Time This feature specifies the ON time for the indicator LED while in Flash Mode. The selectable range is 100 to 9,900 milliseconds (0.1 to 9.9 seconds), in 100 millisecond increments. Follow these instructions to set this feature. 1. Determine the desired setting in milliseconds. 2. Divide the desired setting by 100 (setting is in 100ms increments). Pad the result with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc. 3.
Scanning Features Flash Off Time This feature specifies the OFF time for the indicator LED while in Flash Mode. The selectable range is 100 to 9,900 milliseconds (0.1 to 9.9 seconds), in 100 millisecond increments. Follow these instructions to set this feature. 1. Determine the desired setting in milliseconds. 2. Divide the desired setting by 100 (setting is in 100ms increments). Pad the result with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc. 3.
References Display Settings Display Mode The user can control the reader display behavior according to the following selections: Local Echo mode: When a barcode is read with the reader: • The code is sent to the Host. • The reader display is cleared. • The code is also sent to the reader display (Local Echo). • The cursor is positioned after the last printed character on the reader display. Normal mode: When a barcode is read with the reader: • The code is sent to the Host.
RF Features Follow these instructions to select the delimiter character: 1. Determine the desired character, then find its hexadecimal equivalent on the ASCII Chart on the inside back cover. A setting of 00 specifies no delimiter character. 2. Go to page 271 and scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming Mode. 3. Scan the barcode: SET SOURCE RADIO ADDRESS DELIMITER CHARACTER. 4.
References STAR Radio Protocol Timeout This parameter sets the valid wait time before transmission between the handheld reader and Base Station is considered failed. When setting this parameter, take into consideration the radio traffic (number of readers in the same area). The selectable range for this feature is from 02 to 25 seconds. Follow these instructions to set this feature: 1. Determine the desired setting. 2. Pad the number with leading zeroes to yield two digits.
RF Features BT-Only Features BT Pin Code This option specifies the pin code (either 4- or 16-characters) to be used for authentication of the BT link. To set the pin code: 1. Scan the ENTER/EXIT PROGRAMMING MODE bar code to enter Programming Mode, then enable "BT Security Mode" on page 280. 2. Specify the desired pin code length (4 or 16) by scanning the appropriate bar code in "Select PIN Code Length" on page 281. 3. Determine the desired characters. For example, D254 or TOR12345678135M 4.
References NOTES 322 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300
Chapter 7 Message Formatting Message Formatting Message Formatting is only available for the Gryphon™ Mobile model. A message from the Host to the base must follow these rules: • If Address stamping options or address delimiter are enabled on the base, the Host replay must have address field and delimiter too. Otherwise the message will be ignored. Address delimiter is present only when address stamping is enabled.
Message Formatting • If you want to control the Scanner's beeper from the host, you will also probably want to disable the good transmission beep that is emitted when the code is received from the cradle. (See Wireless Beeper Features on page 259). The message field can store plain text and escape sequences. • Escape sequences are interpreted as commands. • Plain text is directly printed on the display. If writing beyond the end of line, the display does not wrap automatically.
Message Formatting Clearing Display ESC [ 0 K ESC [ 1 K ESC [ 2 K ESC [ 0 J ESC [ 1 J ESC [ 2 J From cursor position to end of line inclusive From beginning of line to cursor position (not inclusive) Entire line From cursor position to end of display inclusive From beginning of display to cursor position (not inclusive) Entire display; moves cursor to upper left corner on display LED and Beeper Control ESC [ 0 q ESC [ 1 q ESC [ 2 q ESC [ 3 q ESC [ 4 q ESC [ 5 q ESC [ 6 q ESC [ 7 q ESC [ 8 q ESC [ 9 q ESC
Message Formatting Messages from Scanner Command Keys The Gryphon™ I series scanners with display have 3 command keys that can each be associated with a character to send to the host. By pressing the keys on the scanner, the associated character with its relative message formatting is sent to the Host. For example, keys can be used to select items from a menu sent to the scanner display by the application program.
Appendix A Technical Specifications Table 48 contains Physical and Performance Characteristics, User Environment and Regulatory information. Table 49 provides Standard Cable Pinouts. Table 48. Technical Specifications Item Description Physical Characteristics Color Dimensions Weight (without cable) White/Gray Gray/Gray Height 7.1”/181 mm Length 3.9”/100 mm Width 2.8”/71 mm GD 41x0/GD4300 : Approximately 6.0 ounces/169 g GM4100/GBT4100: Approximately 8.7 ounces/246 g BC40x0: Approximately 8.
Technical Specifications Item Description Operating autonomy (continuous reading) Performance Characteristics Light Source GM4100: 50,000 reads (typical) GBT4100: 30,000 reads (typical) GD41x0 model: GD43x0 model: Dual LEDs 650nm Class 2 Laser Roll (Tilt) Tolerance ± 35° from normal Pitch Tolerance GD 41x0/GM4100/GBT4100: ± 65° GD4300: ± 50° Skew (Yaw) Tolerance Field of View Depth of Field (Typical) c ( Minimum Element Width Print Contrast Minimum ± 65° 10” (25.4cm) wide at 12.5” (31.
Technical Specifications Item Description Regulatory Electrical Safety EMI/RFI See the Quick Reference Guide for each specific product for details. Laser Safety LED class safety a. b. c. d. Typical input current measured under factory default configuration. Charge Times are much lower when battery is within daily typical operating condition. 13 mils DOF based on EAN. All others are Code 39.
Technical Specifications Standard Cable Pinouts Figure 20 and Table 49 provide standard pinout information for the Base Station’s interface cable. Figure 20. Standard Cable Pinouts Bottom of Scanner Cable Strain Relief Pin 10 To Host Pin 1 Cable Clip (Latch) Cable Interface Cable Port The signal descriptions in Table 49 apply to the connector on the reader and are for reference only. Table 49.
Technical Specifications LED and Beeper Indications The reader’s beeper sounds and its LED illuminates to indicate various functions or errors on the reader. An optional “Green Spot” also performs useful functions. The tables below list these indications. One exception to the behaviors listed in the tables is that the reader’s functions are programmable, and may or may not be turned on. For example, certain indications such as the power-up beep can be disabled using programming barcode labels. Table 50.
Technical Specifications Table 51. Programming Mode Indications Programming Mode - The following indications ONLY occur when the reader is in Programming Mode. Label Programming Mode Entry A valid programming label has been scanned. Label Programming Mode Rejection of Label A label has been rejected. Label Programming Mode Acceptance of Partial Label In cases where multiple labels must be scanned to program one feature, this indication acknowledges each portion as it is successfully scanned.
Technical Specifications Base Station Indications (Cordless Models ONLY) INDICATION LEDS Power-up Complete Yellow LED on Reader Disabled by the HOST or the communication with HOST is not established Yellow LED blinking ~1Hz Data/labels are transmitted to the HOST Yellow LEDs turned off for 100mSec Programming Mode Yellow LED blinks quickly Base and handheld are exchanging data Red LED blinks quickly Battery charging in progress Red LED on Battery charging complete Green LED on Battery charg
Technical Specifications NOTES 334 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300
Appendix B Standard Defaults The most common configuration settings are listed in the “Default” column of the table below. Page references are also provided for feature descriptions and programming barcodes for each parameter. A column has also been provided for recording of your preferred default settings for these same configurable features. Table 52.
Standard Defaults Parameter Indicate Transmission Failure Default Your Setting Page Number Enable 52 Disable Character ‘D’ 53 Enable Character ‘E’ 53 Country Mode U.S.
Standard Defaults Parameter Default Your Setting Page Number GS1-128 AIM ID Enable 80 Label ID: Pre-loaded Sets USA Set 81 Label ID Control Disable 82 No Mid Label ID Character 89 Disable 90 No Char Conversion 90 0.6 Second 91 Label Gone Timeout 160 ms 93 Sleep Mode Timeout Disable 94 Power On Alert 4 Beeps 96 After Decode 96 Mono 97 Medium 97 Good Read Beep Length 80 ms 98 Good Read Beep Volume High 99 Good Read LED Duration 300 ms 100 Trigger Single 101 0.
Standard Defaults Parameter UPC-A Number System Character Transmission Default Your Setting Page Number Transmit 111 1 112 Enable 113 Send 113 Expand UPC-E to EAN-13 Don’t Expand 114 Expand UPC-E to UPC-A Don’t Expand 114 Transmit 115 2 115 Disable 116 Enable 117 Send 117 EAN-13 Flag 1 Character Transmit 118 EAN-13 ISBN Conversion Disable 118 EAN 13 Minimum Reads 1 119 Disable 120 Enable 121 Send 121 Expand EAN 8 to EAN 13 Disable 122 EAN 8 Minimum Reads 1 12
Standard Defaults Parameter Optional GS1-128 Add-On Timer Default Your Setting Page Number Disable 130 P2 Add-Ons Minimum Reads 2 133 P5 Add-Ons Minimum Reads 1 134 GS1-128 Add-Ons Minimum Reads 1 135 Enable 136 Don’t Calculate 136 Don’t Send 137 Don’t Transmit 138 Disable 138 Auto 139 Code 39 Minimum Reads 2 140 Code 39 Decoding Level 3 141 Code 39 Length Control Variable 142 Code 39 Set Length 1 2 143 Code 39 Set Length 2 50 144 Code 39 Interdigit Ratio 4 145
Standard Defaults Parameter Code 128 Quiet Zones Default Your Setting Page Number Auto 154 Code 128 Minimum Reads 1 155 Code 128 Decoding Level 3 156 Code 128 Length Control Variable 157 Code 128 Set Length 1 1 158 Code 128 Set Length 2 80 159 Code 128 Character Correlation Disable 160 Code 128 Stitching Enable 160 Transmit in GS1-128 data format 161 ISBT 128 Concatenation Disable 162 ISBT 128 Force Concatenation Disable 162 ISBT 128 Concatenation Mode Static 163 ISBT
Standard Defaults Parameter I 2 of 5 Set Length 2 Default Your Setting Page Number 50 175 I 2 of 5 Character Correlation Disable 176 I 2 of 5 Stitching Disable 176 Disable 177 Disable 177 Standard 2 of 5 Enable/Disable Disable 178 Standard 2 of 5 Check Character Calculation Disable 178 Send 179 Standard 2 of 5 Minimum Reads 2 179 Standard 2 of 5 Decoding Level 3 180 Standard 2 of 5 Length Control Variable 180 Standard 2 of 5 Set Length 1 8 181 Standard 2 of 5 Set Length
Standard Defaults Your Setting Page Number Parameter Default Datalogic 2 of 5 Enable/Disable Disable 191 Datalogic 2 of 5 Check Character Calculation Disable 191 Datalogic 2 of 5 Minimum Reads 2 192 Datalogic 2 of 5 Decoding Level 3 192 Datalogic 2 of 5 Length Control Variable 193 Datalogic 2 of 5 Set Length 1 6 characters 194 Datalogic 2 of 5 Set Length 2 50 195 Datalogic 2 of 5 Character Correlation Disable 196 Datalogic 2 of 5 Stitching Disable 196 Disable 197 Don’t Calcu
Standard Defaults Parameter Default Your Setting Page Number Code 11 Code 11 Enable/Disable Disable 212 Check C and K 212 Send 213 Code 11 Minimum Reads 2 213 Code 11 Length Control Variable 214 Code 11 Set Length 1 4 215 Code 11 Set Length 2 50 216 Code 11 Interdigit Ratio 4 217 Code 11 Decoding Level 3 219 Code 11 Character Correlation Disable 220 Code 11 Stitching Disable 220 GS1 DataBar™ Omnidirectional Enable/Disable Disable 221 GS1 DataBar™ Omnidirectional GS1-12
Standard Defaults Parameter Default Your Setting Page Number Code 93 Set Length 1 1 231 Code 93 Set Length 2 50 232 Code 93 Minimum Reads 1 233 Code 93 Decoding Level 3 234 Auto 235 Code 93 Stitching Enable 236 Code 93 Character Correlation Disable 236 Disable 237 Enable Mod10 237 MSI Check Character Transmission Enable 238 MSI Length Control Variable 239 MSI Set Length 1 1 239 MSI Set Length 2 50 240 MSI Minimum Reads 4 241 MSI Decoding Level 3 242 Disable 243
Standard Defaults Parameter Default Your Setting Page Number Code 5 Code 5 Enable/Disable Disable 252 Send 253 Enable 253 Code 4 and 5 Decoding Level 3 254 Code 4 and Code 5 Minimum Reads 1 255 Enable 259 Low 259 Beep Duration 80 msec 260 Beep Volume High 261 Disconnect Beep Enable 261 Base Station Beep Enable 262 Leash Alarm Disable 262 Automatic Configuration Update Enable 264 Automatic Flash Update Disable 265 30 minutes 266 Disable 268 No Delay 269 Unlink
Standard Defaults Parameter Keypad Select Default Your Setting Page Number 3C3D3E 278 Disable 280 Select PIN Code Length Select 4-character BT PIN Code 281 Set PIN Code 31323334 = Default PIN Code is 1234 281 Use Static PIN Code 282 BT HID ALT Mode Disable 282 BT HID Send Unkown ASCII Char Disable 283 BT Poll Rate 20 ms 284 Laser Scan Angle 47 degrees 288 Laser Idle Mode Disable 288 Bi-Directional Read Decoding Enable 289 Always On Scan Mode Timeout 5 Hours 290 Bluetoot
Appendix C Sample Bar Codes The sample bar codes in this appendix are typical representations for their symbology types.
Sample Bar Codes Sample Bar Codes — continued Code 32 Codabar 13579 Code 93 Code 11 123456789 348 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300
Sample Bar Codes GS1 DataBar™ (RSS) GS1 DataBar™ variants must be enabled to read the bar codes below (see GS1 DataBar™ Omnidirectional on page 221).
Sample Bar Codes NOTES 350 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300
Appendix D Keypad Use the barcodes in this appendix to enter numbers as you would select digits/characters from a keypad.
Keypad 6 7 8 9 HID Variable PIN Code Cancel an incomplete HID Variable PIN Code Exit HID Variable PIN Code 352 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300
Keypad A B C D E F Product Reference Guide 353
Keypad NOTES 354 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300
Appendix E Scancode Tables Control Character Emulation Control character emulation selects from different scancode tables as listed in this appendix. Each of the control character sets below are detailed by interface type in the tables. These apply to Wedge and USB Keyboard platforms. Control Character 00 . Characters from 00 to 0x1F are sent as control character Ctrl+Keys, special keys are located from 0x80 to 0xA1. Control Character 01 .
Interface Type PC AT PS/2, USB-Keyboard or USB-Keyboard for APPLE Table 53.
Interface Type PC AT PS/2, USB-Keyboard or USB-Keyboard for APPLE — cont. Table 54. Scancode Set When Control Character is 02 0x x0 x1 x2 x3 x4 x5 X6 x7 x8 x9 xA xB Ar↓ Ar↑ Al↓ Al ↑ Cl ↓ Cl ↑ Cr ↓ Cr ↑ BS Tab S+ Tab Home F1 F2 F3 F5 ESC F7 xE xF Enter Ins Pg Up Pg Dwn 2x Space ! “ # $ % & ‘ ( ) * + , - .
Interface type PC AT PS/2 Alt Mode or USB-Keyboard Alt Mode Table 55.
Interface type PC AT PS/2 Alt Mode or USB-Keyboard Alt Mode — cont. Table 56.
Digital Interface Table 57.
IBM31xx 102-key Table 59.
IBM XT Table 61. Scancode Set When Control Character is 00 or 01 0x 1x X0 NULL C+@ DLE C(S)+P x1 SOH C(S)+A DC1 C(S)+Q x2 STX C(S)+B DC2 C(S)+R x3 ETX C(S)+C DC3 C(S)+S x4 EOT C+D DC4 C(S)+T x5 ENQ C(S)+E NAK C(S)+U x6 ACK C(S)+F SYN C(S)+V x7 BEL C(S)+G ETB C(S)+W x8 BS C(S)+H CAN C(S)+X x9 HT TAB EM C(S)+Y xA LF C(S)+J SUB C(S)+Z xB VT C(S)+K ESC Esc xC FF C(S)+L FS C(S)+\ xD CR Enter GS C+] xE SO C(S)+N RS C(S)+^ xF SI C(S)+O US C(S)+_ 2x Space ! “ # $ % & ‘ ( ) * + , - .
Scancode Tables Microsoft Windows Codepage 1252 Windows-1252 is a character encoding of the Latin alphabet, used by default in the legacy components of Microsoft Windows in English and some other Western languages.
Scancode Tables NOTES 364 Gryphon™ I GD4100/GM4100/GBT4100/L GD4300
Index A Aladdin™ G 16 B barcodes cancel 351 numeric barcodes 351 RS-232 baud rate 65 RS-232 parameters parity 59, 177, 251, 252, 255 battery WARNINGS 15 Beeper Pitch, Good Read 97 Volume, Good Read 99 Beeper, Good Read 96 C Cable Pinouts 330 Clear to Send 291 Code 39 Format 72 Conversion, case 90 Conversion, character 90, 311 Convert to Code 128 76 Convert to Code 39 76 Coupon Control 109 CTS 291 H Handheld Scanner Host Resets 70 68 I IBM interface selection 30 IBM Standard Format 72 Idle State (wand)
Index P Performance Characteristics 328 Physical Characteristics 327 Pitch – Good Read, Beeper 97 Polarity (wand) 74 Prefix/Suffix 78, 305 Product Specifications 327 Programming Barcodes 16 R Read, Beeper – Good 96 Read, Beeper Pitch – Good 97 Read, Beeper Volume – Good 99 Reading Configuration Barcodes 38 Request to Send 291 RS-232 interface selection 30 RS-232 Serial Connection 18 RTS 291 S sample barcodes code 128 347 code 39 347 interleaved 2 of 5 348 Scancode Tables 355 select digits/characters 351
ASCII Chart ASCII Char. Hex No. ASCII Char. Hex No. ASCII Char. Hex No. ASCII Char. Hex No. NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US 00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F SP ! “ # $ % & ’ ( ) * + , .
Australia Datalogic Scanning Pty Ltd Telephone: [61] (2) 9870 3200 australia.scanning@datalogic.com France and Benelux Datalogic Scanning SAS Telephone: [33].01.64.86.71.00 france.scanning@datalogic.com Germany Datalogic Scanning GmbH Telephone: 49 (0) 61 51/93 58-0 germany.scanning@datalogic.com India Datalogic Scanning India Telephone: 91- 22 - 64504739 india.scanning@datalogic.com Italy Datalogic Scanning SpA Telephone: [39] (0) 39/62903.1 italy.scanning@datalogic.