Operation Manual
READING PARAMETERS PARAMETERS
Description Parameter Value
Illumination Mode Disabled
SPIL 00
Triggered
01
Enabled
02
Operating Modes On Line
SNRM 00
Serial On Line
01
Automatic
02
Automatic (Object Sense)
03
Test Mode
04
Test Mode Multiple Disabled
SNTM 00
Enabled
01
Automatic Threshold From 2 to 255 scans without a code
SNAT g
Phase Off Event Trigger Stop
SNTO 00
Timeout
01
Trigger Stop-Timeout
02
Timeout From 40 to 5100 ms
SNET h
Serial Start Any string of characters (max 20) between 00-FE
STON i
Serial Stop Any string of characters (max 20) between 00-FE
STOF i
Label Programming Mode Disabled
FAPM 00
Enabled
01
Exposure Mode Continuous
SPST 00
Strobed
SPST 01
Software Configuration Strings
214
Gryphonâ„¢ I GFS4170/GFS4150-9
g = Hex value from 02 to FF representing the number of scans without a code
h = Hex value from 02 to FF repres
enting the decimal number (x20 ms)
i = Hex value
from 00 to FE representing the ASCII character