Code 93 ENTER/EXIT PROGRAMMING MODE
184
Gryphonâ„¢ I GFS4170/GFS4150-9
Code 93 Check Character Transmission
Enables/disables transmission of an optional Code 93 check character.
Code 93 Check Character Transmission = Disable
Code 93 Check Character Transmission = Enable
DEFAULT
Code 93 Length Control
This feature specifies either variable length decoding or fixed length decoding for the Code 93
symbology.
Variable Length.
For variable length decoding, a minimum and maximum length may be set.
Fixed Length.
For fixed length decoding, two different lengths may be set.
DEFAULT
Code 93 Length Control = Variable Length
Code 93 = Fixed Length