Australia Japan Datalogic Scanning Pty Ltd North Ryde, Australia Telephone: [61] (2) 9870 3200 Fax: [61] (2) 9878 8688 Datalogic Scanning KK Shinagawa, Tokyo, Japan Telephone: 81 (0)3 3491 6761 Fax: 81 (0)3 3491 6656 France and Benelux Latin America Datalogic Scanning Sarl LES ULIS Cedex, France Telephone: [33].01.64.86.71.00 Fax: [33].01.64 46.72.
Datalogic Scanning, Inc. 959 Terry Street Eugene, Oregon 97402 Telephone: (541) 683-5700 Fax: (541) 345-7140 An Unpublished Work - All rights reserved. No part of the contents of this documentation or the procedures described therein may be reproduced or transmitted in any form or by any means without prior written permission of Datalogic Scanning, Inc. or its subsidiaries or affiliates ("Datalogic" or “Datalogic Scanning”).
CONTENTS UPDATES AND LANGUAGE AVAILABILITY................................................... IV USING GRYPHON™ BT SERIES READERS.................................................... 1 GUIDE TO SYSTEM START UP ........................................................................ 2 CONNECTING OM-GRYPHON™ BT/C-GRYPHON.......................................... 2 CHARGING THE BATTERIES ........................................................................... 3 Changing the Batteries.........................
UPDATES AND LANGUAGE AVAILABILITY UK/US The latest drivers and documentation updates for this product are available on Internet. Log on to: www.scanning.datalogic.com I Su Internet sono disponibili le versioni aggiornate di driver e documentazione di questo prodotto. Questo manuale è disponibile anche nella versione italiana. Collegarsi a: www.scanning.datalogic.com F Les versions mises à jour de drivers et documentation de ce produit sont disponibles sur Internet.
Gryphon™ BT Cordless Reading Systems USING GRYPHON™ BT SERIES READERS ® The Gryphon™ BT (Gryphon™ Bluetooth ) reader is a CCD wireless barcode scanner which is part of one of the Cordless Reading Systems described below: CSR Kit When paired with the OM-Gryphon™ BT cradle, Gryphon™ BT builds a Cordless Reading System for the collection, decoding and transmission of barcoded data. OM-Gryphon™ BT can be connected to a Host PC through a USB, RS232, Wedge or Pen emulation cable.
DATALOGIC GUIDE TO SYSTEM START UP CSR KIT 1. Connect the OM-Gryphon™ BT cradle to a power supply and charge the Gryphon™ BT battery as described in this Quick Reference manual. A full charge takes less than 5 hours with NiMh batteries. 2. Connect the OM-Gryphon™ BT cradle to the Host PC and configure the reader as described in this Quick Reference manual under "Setting Up Gryphon™ BT with OM-Gryphon™ BT". CS KIT 1.
Gryphon™ BT Cordless Reading Systems To disconnect the Host Interface cable, insert a paper clip or other similar object into the hole corresponding to the Host connector on the body of the cradle. Push down on the clip while unplugging the cable. Refer to the following figure: Disconnecting the Cable CHARGING THE BATTERIES By placing the reader onto the OM-Gryphon™ BT cradle or C-Gryphon battery charger it is possible to charge the Gryphon™ BT batteries. Make sure the charging LED goes on.
DATALOGIC Gun Locator/ Battery reconditioning button Charging (red LED) Charge completed (green LED) A SCH RGE DI Power on / Data (yellow LED) After many recharging cycles NiMh and NiCd batteries may tend to lose their operating autonomy. This condition can be overcome by positioning the Gryphon™ BT onto the OM-Gryphon™ BT cradle or C-Gryphon charger and pressing the “battery reconditioning” button. A complete discharge cycle will be performed and then the battery will be recharged.
Gryphon™ BT Cordless Reading Systems GRYPHON™ BT OPERATION RADIO CONNECTION The blue LED and/or the beeper always indicate the reader radio connection status (see the table below): • the radio connection is signaled by the blue LED through a single blink at regular intervals, while if the reader radio is disconnected the LED emits two short blinks at regular intervals; • during the initialization procedure, if the radio connection attempt is successful, the reader emits four ascending tones; • the rad
DATALOGIC INITIAL SETUP This procedure allows setting up the reader to operate with the default settings. Two different procedures are available according to the type of application you are working with: CSR Kit: Gryphon™ BT paired to the OM-Gryphon™ BT (follow the procedures indicated in the paragraph below); CS Kit: ® Gryphon™ BT communicating with a Bluetooth device (follow the procedures indicated in the paragraph starting on page 15).
Gryphon™ BT Cordless Reading Systems Blue LED Wait for a series of beeps (three sequences of tones separated by a pause) indicating Bluetooth connection. 4. Configure the OM-Gryphon™ BT cradle. Refer to the following paragraphs depending on the interface selection code required for your application. USB Interface Selection OM-Gryphon™ BT Host USB The USB interface is compatible with: Windows 98 (and later) Mac OS 8.
DATALOGIC USB START-UP As with all USB devices, upon connection, the Host performs several checks by communicating with the OM-Gryphon™ BT. Before the OM-Gryphon™ BT is ready, the correct USB driver must be loaded. For all systems, the correct USB driver for the default USB-KBD interface is included in the Host Operating System and will either be loaded automatically or will be suggested by the O.S. and should therefore be selected from the dialog box (the first time only).
Gryphon™ BT Cordless Reading Systems USB USB-KBD (default) Ì$+UA03$-:Î USB-KBD-ALT-MODE Ì$+UA04$-@Î USB-KBD-APPLE Ì$+UA05$-FÎ USB-COM* Ì$+UA02$-4Î USB-IBM-Table Top Ì$+UA00$-(Î USB-IBM-Hand Held Ì$+UA01$-.Î * When configuring USB-COM, the relevant files and drivers must be installed from the USB Device Installation software which are available on the CDROM and can also be downloaded from the web site (see http://www.scanning.datalogic.com).
DATALOGIC RS232 Interface Selection OM-Gryphon™ BT Host RS232 1. Read the OM-Gryphon™ BT restore default code: Restore OM-Gryphon™ BT Default Ì$+RX0$-qÎ 2.
Gryphon™ BT Cordless Reading Systems WEDGE Interface Selection Host OM-Gryphon™ BT WEDGE 1. Read the OM-Gryphon™ BT restore default code: Restore OM-Gryphon™ BT Default Ì$+RX0$-qÎ 2.
DATALOGIC IBM SURE1 Ì$+CP506$-$Î IBM Terminal 3153 Ì$+CP504$-}Î IBM Terminals 31xx, 32xx, 34xx, 37xx: To select the interface for these IBM Terminals, read the correct key transmission code. Select the keyboard type if necessary (default = advanced keyboard).
Gryphon™ BT Cordless Reading Systems IBM AT - ALT mode Ì$+CP507$-+Î PC Notebook - ALT mode Ì$+CP508$-2Î WYSE TERMINALS ANSI Keyboard Ì$+CP509$-9Î PC Keyboard Ì$+CP510$-gÎ ASCII Keyboard Ì$+CP511$-nÎ VT220 style Keyboard Ì$+CP514$-ÇÎ DIGITAL TERMINALS VT2xx/VT3xx/VT4xx Ì$+CP512$-uÎ APPLE APPLE ADB Bus Ì$+CP513$-|Î 13
DATALOGIC PEN Emulation Interface Selection 1. Read the OM-Gryphon™ BT restore default code: Restore OM-Gryphon™ BT Default Ì$+RX0$-qÎ 2.
Gryphon™ BT Cordless Reading Systems SETTING UP GRYPHON™ BT WITH BLUETOOTH® DEVICE Follow one of the following two procedures to set up Gryphon™ BT as Slave or as Master according to your application. Setup for Gryphon™ BT as Slave A Gryphon™ BT is Slave when it sends barcodes to a Master remote ® Bluetooth device such as a PC, Laptop, PDA, etc, which has initialized the communication.
DATALOGIC Laptop ® (Bluetooth device) Slave Master Gryphon™ BT readers Slave ® If the Master Bluetooth device can support a piconet, the communication can be established with up to 7 seven Slave readers at the same time. To configure the Gryphon™ BT as Slave follow the given procedure. 1. Restore Gryphon™ BT Default Ì$+$*oÎ 2. Set Gryphon™ BT as Slave Ì$+QT0$-^Î YOUR READER IS NOW READY TO BE DISCOVERED (CONNECTED VIA ® RADIO) BY A BLUETOOTH MASTER DEVICE AND READ BARCODES.
Gryphon™ BT Cordless Reading Systems Setup for Gryphon™ BT as Master ® A Gryphon™ BT is Master when the remote Bluetooth device is Slave, i.e. with ® a Bluetooth barcode printer. Once set as Master, a Gryphon™ BT reader must be configured with the address of the Slave device to which it wants to communicate. As Master it can initiate a connection with only one Slave device. By default, at startup the reader initializes the communication with the Slave.
DATALOGIC 3. Enter Configuration Ì$+;Î 4. ® Set Remote Bluetooth Device Address (slave) ÌQSQÎ + 12 characters (in HEX format) ® for the remote Bluetooth device address ® specified in each Bluetooth device. 5. Exit and Save Configuration Ì$-?Î 6. Request Radio Connection with Slave Ì$+QC1$-ÊÎ If the connection is not successful, you can attempt a connection manually by double-clicking the reader trigger. YOUR READER IS NOW CONFIGURED TO READ BARCODES USING THE DEFAULT VALUES.
Gryphon™ BT Cordless Reading Systems HEX NUMERIC TABLE Ì01Î 0 Ì23Î 2 Ì45Î 4 Ì67Î 6 Ì89Î 8 ÌABÎ A ÌCDÎ C ÌEFÎ E Ì12Î 1 Ì34Î 3 Ì56Î 5 Ì78Î 7 Ì9:Î 9 ÌBCÎ B ÌDEÎ D ÌFGÎ F 19
DATALOGIC GRYPHON™ BT DEFAULT CONFIGURATION USB DATA FORMAT: code identifier disabled, no field adjustment, code length not transmitted, character replacement disabled, address stamping = disabled, address delimiter = disabled. USB KEYBOARD: USA keyboard, inter-character and inter-code delays disabled. USB COM: no handshaking, delay disabled, rx timeout 5 sec., ack/nack disabled, serial trigger lock disabled.
Gryphon™ BT Cordless Reading Systems WEDGE USA keyboard, caps lock off, caps lock auto-recognition enabled, num lock unchanged, inter-character and inter-code delays disabled, DATA FORMAT: code identifier disabled, no field adjustment, code length not transmitted, no header, terminator = ENTER, character replacement disabled, address stamping = disabled, address delimiter = disabled, PEN EMULATION interpret mode, conversion to code 39 disabled, output level normal, idle level normal, minimum output pulse 6
DATALOGIC CODE SELECTION enabled codes BT200 Code PDF417 EAN 8/EAN 13 / UPC A/UPC E without ADD ON check digit transmitted, no conversions BT100 BT200 Interleaved 2/5 check digit control and transmission, variable length code; 4-99 characters Standard Code 39 no check digit control, variable length code; 1-99 characters Code 128, variable length code; 1-99 characters disabled codes BT100 EAN 128, ISBT128, Code 93, Codabar, pharmaceutical codes, MSI, Plessey, Telepen, Delta IBM, Code 11, Code 16K, Code
Gryphon™ BT Cordless Reading Systems TECHNICAL FEATURES Gryphon™ BT Electrical Features Battery Type Time of recharge Operating autonomy (typ. continuous reading) Max scan rate Indicators Optical Features Sensor Illuminator Wavelength Max. LED Output Power LED Safety Class Reading field Max. resolution PCS minimum Reading Pitch angle Reading Skew angle Reading Tilt angle 2 AA NiMh batteries* 1.2 V – 1850 mAh or 2100 mAh max.
DATALOGIC OM-Gryphon™ BT Electrical Features Supply voltage Power consumption Indicators Time of recharge Environmental Features Working temperature Storage temperature Humidity Protection class Communications Interface Mechanical Features Weight Dimensions Material 9..28 Vdc max. 8 W (charging) * Battery charging (red) Charge completed (green) Power/Data (yellow) max.
Gryphon™ BT Cordless Reading Systems READING DIAGRAMS GRYPHON™ BT100 Reading Zones (10° skew angle) 15 0.13 mm (5 mils) 10 5 CODE 39 0.076 mm (3 mils) 0 CODE 39 1 mm (40 mils) EAN13 M=1 0.33 mm (13 mils) CODE 39 0.13 mm (5 mils) -5 -10 -15 0 5 10 15 20 25 30 40 35 (cm) GRYPHON™ BT200 Reading Zones (10° skew angle) 10 0.13 mm (5 mils) 5 CODE39 CODE39 0.076 mm 0.13 mm (3 mils) (5 mils) 0 EAN13 M=1 0.33 mm (13 mils) CODE39 0.
DATALOGIC TROUBLESHOOTING Problem Solution The beeper and LED signal radio disconnection from the ® remote Bluetooth device. The distance between the remote device and Gryphon™ BT may be too far or there may be obstacles to radio transmission between them. Reconnect. The requested radio connection by Gryphon™ BT Master does not activate. Reduce the distance between the devices.
Gryphon™ BT Cordless Reading Systems Unbind Ì$+QT0$-^Î Power OFF Ì#+Poff4Î SERVICES AND SUPPORT Datalogic provides several services as well as technical support through its website. Log on to www.scanning.datalogic.
DATALOGIC PATENTS This product is licensed under the U.S. patent 6,158,661 This product is covered by one or more of the following patents: U.S. patents: 5,992,740; 6,305,606 B1; 6,517,003 B2; 6,631,846 B2; 6,712,271 B2; 6,808,114 B1; 6,817,525 B2 and 6,834,806 B2; European patents: 851,378 B1; 895,175 B1; 962,880 B1; 997,760 B1; 1,128,315 B1 and 1,164,536 B1. Additional patents pending. COMPLIANCE This device must be opened by qualified personnel only.
Gryphon™ BT Cordless Reading Systems RADIO COMPLIANCE Contact the competent authority responsible for the management of radio frequency devices of your country to verify the eventual necessity of a user license. Refer to the web site http://europa.eu.int/comm/enterprise/rtte/spectr.htm for further information. POWER SUPPLY For OM-Gryphon™ BT and C-Gryphon This device is intended to be supplied by a UL Listed or CSA Certified Power Unit marked "Class 2" or "LPS" output rated 9-28 V, minimum 0.
Datalogic Scanning, Inc.
Australia Japan Datalogic Scanning Pty Ltd North Ryde, Australia Telephone: [61] (2) 9870 3200 Fax: [61] (2) 9878 8688 Datalogic Scanning KK Shinagawa, Tokyo, Japan Telephone: 81 (0)3 3491 6761 Fax: 81 (0)3 3491 6656 France and Benelux Latin America Datalogic Scanning Sarl LES ULIS Cedex, France Telephone: [33].01.64.86.71.00 Fax: [33].01.64 46.72.