User Manual
1D Code Selection Enter/Exit Programming Mode
Product Reference Guide
195
Code 93 Check Character Transmission
Enables/disables transmission of an optional Code 93 check character.
$CC9CT00(CR)
Code 93 Check Character Transmission = Disable
$CC9CT01(CR)
Code 93 Check Character Transmission = Enable
Code 93 Length Control
This feature specifies either variable length decoding or fixed length decod-
ing for the Code 93 symbology.
Variable Length:
For variable length decoding, a minimum and maximum
length may be set.
Fixed Length:
For fixed length decoding, two different lengths may be set.
$CC9LC00(CR)
Code 93 Length Control = Variable Length
$CC9LC01(CR)
Code 93 = Fixed Length
DEFAULT
DEFAULT