Operation Manual

Reading Parameters Enter/Exit Programming Mode
Product Reference Guide
83
Presentation Mode Indication
This operation is useful for indicating when the reader is in Automatic/Triggered Object Sense
Operating Mode. If enabled, the blue indicator will blink when Presentation Mode scanning is
active.
DEFAULT
$CSMFL00(CR)
Presentation Mode Indication = Disable
$CSMFL01(CR)
Presentation Mode Indication = Enable
Manual Trigger Control
This feature is available in Serial On Line mode only.
This feature is used to enable/disable manual trigger when the reader is in Serial On Line
reading mode.
Enable: allows a manual trigger push to start a r
eading phase.
Disable: (default) locks out the trigger button and does not allow manual triggering to
start a re
ading phase. When disabled, the trigger can still be activated once by pressing and
holding the trigger for 5 seconds to enter Debug Mode.
DEFAULT
$CSOTM00
Manual Trigger Control = Disable
$CSOTM01
Manual Trigger Control = Enable