Operation Manual

Technical Specifications
280
Gryphon™ I GFS4400
RS-232 Electrical Connections
9-pin connector
1 Trigger Trigger signal input (see
Figure 8
and
Figure 9
on next page)
2 TX Transmit Data (output from sca
nner)
3 RX Receive Data (input to scanner)
4 NC Not connected
5 GND Ground
6 VCC +5Vdc
7 CTS Clear To Send (input to scanner)
8 RTS Request To Send (output from scanner)
9 DIGITAL OUTPUT Output signal (see
Figure 7
)
Default configuration is RS-232: 9600, 8, N, 1, no handshaking, ACK/NAK disabled.
NOTE: The Scanner can also decode mirrored images o
f 2D m
atrix codes Datamatrix, QR Code
and Maxicode.
Interfaces Supported
GFS4450-9 version: RS-232 Standard
GFS4470 version:USB-COM, USB-Keyboard, USB-OEM
User Environment
Operating Temperature -4° to 122° F (-20° to 50° C)
Storage Temperature -4° to 158° F (-20° to 70° C)
Humidity Operating: 5% to 90% relative humidity, non condensing
Drop specifications 5 drops from 30 inches (0.76 mt.) to concrete
Ambient Light immunity Up to 100,000 Lux
Contaminants IEC529-IP54
ESD Level +/-16Kv
Regulatory
LED Emission Class
(IEC-62471:2006-07) Exempt (No Risk)
IEC60825-1: 2007
Electrical Safety IEC 60950-1 , CAN/CSA C22.2 No. 60950-1-07; UL 60950-1
EMI/RFI
North America (FCC) : Part 15 Class B, Canada ( IC) : ICES-003
Class B,
European Union EMC Directive, Australian (C-tick), Rus-
sia (Gost)