Operation Manual
Software Configuration Strings
Product Reference Guide
239
Set Length Length 1 (or Min Length) from 1 to 74 characters
XBL1 w
Length 2 (or Max Length) 0 or from 1 to 74 characters
XBL2 w
Expanded Decoding Options
Minimum Reads One Read
XBMR 01
Two Reads
02
Three Reads
03
Four Reads
04
Coupon Control Allow all coupon barcodes to be decoded
CPCL 00
Enable only UPC-A coupon decoding
01
Enable only GS1 Databar coupon decoding
02
GS1 Databar Limited
GS1 Databar Limited Disable
LBEN 00
Enable
01
GS1-128 Emulation Disable
LBU8 00
Enable
01
Limited Decoding Options
Minimum Reads One Read
LBMR 01
Two Reads
02
Three Reads
03
Four Reads
04
Code 93
Code 93 Disable
C9EN 00
Enable
01
Code Length Control Variable
C9LC 00
Fixed
01
Set Length Length 1 (or Min Length) from 1 to 50 characters
C9L1 v
Length 2 (or Max Length) 0 or from 1 to 50 characters
C9L2 v
Check Options
Check Calculation Disable
C9CC 00
Enable Check C
01
Enable Check K
02
Enable Check C and K
03
Check Tx Disable
C9CT 00
Enable
01
Decoding Options
Minimum Reads One Read
C9MR 01
w
= Hex value from 00 to 4A representing the decimal number
v = Hex value from 00 or 02 to 32 representing the decimal number
CODE SELECTION
Description Parameter Value